Comparative assessment of the corneal incision enlargement of 4 preloaded IOL delivery systems

被引:11
|
作者
Liu, Jingbo [1 ]
Wolfe, Patricia [1 ]
Hernandez, Victor [1 ]
Kohnen, Thomas [2 ]
机构
[1] Alcon Vsion LLC, Ft Worth, TX USA
[2] Goethe Univ, Dept Ophthalmol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
关键词
FOLDABLE INTRAOCULAR LENSES; INDUCED ASTIGMATISM; DYNAMIC MORPHOLOGY; MOTORIZED INJECTOR; CATARACT-SURGERY; PHACOEMULSIFICATION; IMPLANTATION; INTEGRITY; SIZES; SUTURELESS;
D O I
10.1097/j.jcrs.0000000000000214
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the corneal incision size enlargement after intraocular lens (IOL) implantation of a new, automated, preloaded delivery system, AutonoMe (system A), vs that of 3 other available preloaded systems (UltraSert [system U], Vivinex iSert [system V], and Tecnis iTec [system T]). Setting: Alcon Vision LLC, Fort Worth, Texas, USA. Design: Experimental study. Methods: Human cadaver eyes were randomly assigned to receive IOLs implanted with the preloaded delivery devices. Corneal incisions were imaged using optical coherence tomography, and incision sizes were measured using an Asico incision gauge before and after IOL delivery. Differences in mean incision enlargement between delivery devices were evaluated using a paired t test. Results: System A (mean +/- standard deviation, 0.29 +/- 0.03 mm) and system U (0.29 +/- 0.03 mm) had the smallest mean incision size enlargement compared with system T (0.31 +/- 0.03 mm) and system V (0.36 +/- 0.06 mm). System V had the largest corneal incision enlargement and was significantly larger than system A (P =.001), system U (P =.001), and system T (P =.002). System A was noninferior to system U; the paired difference in corneal incision enlargement between the devices was similar to 0.01 +/- 0.04 mm (90% CI, similar to 0.03 to 0.01). Conclusions: The new system A preloaded delivery system provided smaller corneal incision enlargement compared with system T or system V and was noninferior to system U. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS.
引用
收藏
页码:1041 / 1046
页数:6
相关论文
共 5 条
  • [1] Comparative evaluation of corneal incision enlargement after intraocular lens delivery of new preloaded and manual implantation systems
    Wang, Lixin
    Wolfe, Patricia
    Paliwal, Sumit
    Chernosky, Alexis
    Kohnen, Thomas
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (01) : 83 - 87
  • [2] Effect of manual, preloaded, and automated preloaded injectors on corneal incision architecture after IOL implantation
    Cennamo, Michela
    Favuzza, Eleonora
    Salvatici, Maria Cristina
    Giuranno, Gabriele
    Buzzi, Matilde
    Mencucci, Rita
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (10) : 1374 - 1380
  • [3] Enlargement of main corneal incision: clinical intraindividual comparison of two preloaded intraocular lens injectors
    Khoramnia, Ramin
    Baur, Isabella D.
    Labuz, Grzegorz
    Chychko, Lizaveta
    Koeppe, Maximilian K.
    Hallak, Mustafa K.
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (02) : 165 - 170
  • [4] Corneal Incision Enlargement in Two Preloaded Intraocular Lens Injectors: An Intraindividual In Vivo Study
    Yildirim, Timur M.
    Labuz, Grzegorz
    Baur, Isabella D.
    Poompokawat, Piyanut
    Knorz, Michael C.
    Auffarth, Gerd U.
    Khoramnia, Ramin
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (05) : 331 - +
  • [5] In vitro comparison of delivery performance of 4 preloaded intraocular lens injector systems for corneal and sclerocorneal incisions
    Oshika, Tetsuro
    Wolfe, Patricia
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06) : 840 - 846