A novel 99mTc delivery system using (n,γ)99Mo adsorbed on a large alumina column in tandem with Dowex-1 and AgCl columns

被引:27
作者
Chattopadhyay, S
Das, MK [1 ]
Sarkar, SK
Saraswathy, P
Ramamoorthy, N
机构
[1] Bhabha Atom Res Ctr, Ctr Variable Energy Cyclotron, Board Radiat & Isotope Technol, Radiopharmaceut Lab, Kolkata 700064, W Bengal, India
[2] BRIT, Radiopharmaceut Lab, Navi Mumbai 400705, India
关键词
post-elution concentration of pertechnetate 'jumbo' alumina column Mo-99-Tc-99m generator; Dowex-1 trap for pertechnetate; AgCl column; W-188-Re-188; generator;
D O I
10.1016/S0969-8043(02)00080-5
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Mo-99 of specific activity 7.4-14.8 GBq (200-400 mCi)/g was adsorbed on a 'jumbo' alumina column (40 g. ;90 mm(H) x 20 mm (dia.): 50 g. 65 mm (H) x 35 mm (dia.). [Tc-99m] TcO4-, eluted with 50-70 ml normal saline and applied to a tiny column of a strong anion exchanger. Dowex-1 x 8, 10-15 mg. 8-12 mm (H) x 1 mm (dia.). Pertechnetate was eluted from the Dowex-1 column with 5-6 nil of 0.2 M NaI followed by washing with 1.5-1.8 ml water. Iodide was removed from this eluate by passage through a 1 g AgCl column (12 mm (H) x 8 mm (dia.)). The final product, pertechnetate, was recovered in 6.5-7.8 ml. while the NaCl content was close to that of normal saline. Each elution operation was complete in similar to45 min. The mean practical yield was similar to86% (n = 5), Closed cycle operation with sterile connecting tubes and multi-way stop-cocks was practised. The quality of the [Tc-99m]NaTcO4 thus obtained complies with the specifications applicable for radiopharmaceutical use. The major merit over other post-elution concentration methods is that the new procedure can function nearly independently of the volume of the primary eluate (in normal saline) from the alumina column generator (ACG). Tc-99m generators containing as much as 80-100 g alumina for holding 14.8-18.5 GBq (400--500 mCi) Mo-99 (at the reference time) are feasible using similar to15 mg Dowex-1 bed mass. A relatively user-friendly-cum-producer-friendly Tc-99m generator system has been demonstrated making use of the inexpensive and easy to prepare (n,y)Mo-99. The method is also applicable for the more costly W-188-Re-188 generator. Published by Elsevier Science Ltd.
引用
收藏
页码:7 / 16
页数:10
相关论文
共 20 条
[1]   EXTENDING THE LIFE OF A 99TCM GENERATOR - A SIMPLE AND CONVENIENT METHOD FOR CONCENTRATING GENERATOR ELUATE FOR CLINICAL USE [J].
BLOWER, PJ .
NUCLEAR MEDICINE COMMUNICATIONS, 1993, 14 (11) :995-997
[2]  
EVANS JV, 1987, APPL RADIAT ISOTOPES, V38, P19
[3]  
Guhlke S, 2000, J NUCL MED, V41, P1271
[4]  
GUHLKE S, 1998, J LABELLED COMPD RAD, V40, P274
[5]  
GUHLKE S, 1997, J NUCL MED, V38, P125
[6]   PROCESSING OF REACTOR-PRODUCED W-188 FOR FABRICATION OF CLINICAL-SCALE ALUMINA-BASED W-188/RE-188 GENERATORS [J].
KNAPP, FF ;
CALLAHAN, AP ;
BEETS, AL ;
MIRZADEH, S ;
HSIEH, BT .
APPLIED RADIATION AND ISOTOPES, 1994, 45 (12) :1123-1128
[7]  
KNAPP FF, 1998, 188IAEATECDOC1029419
[8]  
KNAPP FF, 1993, Patent No. 5186913
[9]  
KNAPP FF, 1994, Patent No. 5275802
[10]  
KNAPP FF, 1998, IAEATECDOC1029, P485