Treatment vault shielding for a flattening filter-free medical linear accelerator

被引:29
|
作者
Kry, Stephen F. [1 ]
Howell, Rebecca M. [1 ]
Polf, Jerimy [1 ]
Mohan, Radhe [1 ]
Vassiliev, Oleg N. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 05期
关键词
UNFLATTENED PHOTON BEAMS; DOSIMETRIC PROPERTIES; MONTE-CARLO;
D O I
10.1088/0031-9155/54/5/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target current requirements were determined from treatment planning studies of several disease sites with, and without, the flattening filter. The flattened beam shielding data were compared to data published in NCRP Report No. 151, and the unflattened beam shielding data were presented relative to the NCRP data. Finally, the shielding requirements for a typical treatment vault were determined for a single-energy ( 6 MV) linac and a dual-energy ( 6 MV/18 MV) linac. With the exception of large-angle patient scatter fractions and wall scatter fractions, the vault shielding parameters were reduced when the flattening filter was removed. Much of this reduction was consistent with the reduced average energy of the FFF beams. Primary beam TVLs were reduced by 12%, on average, and small-angle scatter fractions were reduced by up to 30%. Head leakage was markedly reduced because less integral target current was required to deliver the target dose. For the treatment vault examined in the current study, removal of the flattening filter reduced the required thickness of the primary and secondary barriers by 10-20%, corresponding to 18 m(3) less concrete to shield the single-energy linac and 36 m3 less concrete to shield the dual-energy linac. Thus, a shielding advantage was found when the linac was operated without the flattening filter. This translates into a reduction in occupational exposure and/or the cost and space of shielding.
引用
收藏
页码:1265 / 1273
页数:9
相关论文
共 33 条
  • [1] A Monte Carlo study of a flattening filter-free linear accelerator verified with measurements
    Dalaryd, Marten
    Kragl, Gabriele
    Ceberg, Crister
    Georg, Dietmar
    McClean, Brendan
    af Wetterstedt, Sacha
    Wieslander, Elinore
    Knoos, Tommy
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (23): : 7333 - 7344
  • [2] Impact of a flattening filter free linear accelerator on structural shielding design
    Jank, Julia
    Kragl, Gabriele
    Georg, Dietmar
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2014, 24 (01): : 38 - 48
  • [3] Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator
    Mesbahi, Asghar
    Nejad, Farshad Seyed
    RADIATION MEDICINE, 2008, 26 (06): : 331 - 336
  • [4] Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator
    Asghar Mesbahi
    Farshad Seyed Nejad
    Radiation Medicine, 2008, 26 : 331 - 336
  • [5] Dosimetric properties of equivalent-quality flattening filter-free (FFF) and flattened photon beams of Versa HD linear accelerator
    Meshram, Mukesh N.
    Pramanik, Srimanta
    Ranjith, C. P.
    Gopal, Saravana K.
    Dobhal, Rishabh
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 358 - 370
  • [6] COMMISSIONING OF PHOTON BEAMS OF A FLATTENING FILTER-FREE LINEAR ACCELERATOR AND THE ACCURACY OF BEAM MODELING USING AN ANISOTROPIC ANALYTICAL ALGORITHM
    Hrbacek, Jan
    Lang, Stephanie
    Kloeck, Stephan
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (04): : 1228 - 1237
  • [7] Photon beam quality variations of a flattening filter free linear accelerator
    Georg, Dietmar
    Kragl, Gabriele
    Af Wetterstedt, Sacha
    McCavana, Patrick
    McClean, Brendan
    Knoos, Tommy
    MEDICAL PHYSICS, 2010, 37 (01) : 49 - 53
  • [8] Clinically relevant investigation of flattening filter-free skin dose
    Guy, Christopher L.
    Karki, Kishor
    Sharma, Manju
    Kim, Siyong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 140 - 148
  • [9] Pinnacle3 modeling and end-to-end dosimetric testing of a Versa HD linear accelerator with the Agility head and flattening filter-free modes
    Saenz, Daniel L.
    Narayanasamy, Ganesh
    Cruz, Wilbert
    Papanikolaou, Nikos
    Stathakis, Sotirios
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 192 - 206
  • [10] Effects of flattening filter-free and volumetric-modulated arc therapy delivery on treatment efficiency
    Thomas, Evan M.
    Popple, Richard A.
    Prendergast, Brendan M.
    Clark, Grant M.
    Dobelbower, Michael C.
    Fiveash, John B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06): : 155 - 166