In Vivo Reconstruction of the Acetabular Bone Defect by the Individualized Three-Dimensional Printed Porous Augment in a Swine Model

被引:3
作者
Fu, Jun [1 ]
Xiang, Yi [2 ]
Ni, Ming [1 ]
Qu, Xiaojuan [3 ]
Zhou, Yonggang [1 ]
Hao, Libo [1 ]
Zhang, Guoqiang [1 ]
Chen, Jiying [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Orthopaed, Beijing 100853, Peoples R China
[2] Logist Support Forces Chinese PLA 985 Hosp, Dept Orthopaed, Taiyuan 030001, Shanxi, Peoples R China
[3] Logist Support Forces Chinese PLA 985 Hosp, Otolaryngol Dept, Taiyuan 030001, Shanxi, Peoples R China
关键词
TI6AL4V SCAFFOLD; ARTHROPLASTY; HIP; OSSEOINTEGRATION; BIOCOMPATIBILITY; POROSITY;
D O I
10.1155/2020/4542302
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background and Purpose. This study established an animal model of the acetabular bone defect in swine and evaluated the bone ingrowth, biomechanics, and matching degree of the individualized three-dimensional (3D) printed porous augment. Methods. As an acetabular bone defect model created in Bama miniswine, an augment individually fabricated by 3D print technique with Ti6Al4V powders was implanted to repair the defect. Nine swine were divided into three groups, including the immediate biomechanics group, 12-week biomechanics group, and 12-week histological group. The inner structural parameters of the 3D printed porous augment were measured by scanning electron microscopy (SEM), including porosity, pore size, and trabecular diameter. The matching degree between the postoperative augment and the designed augment was assessed by CT scanning and 3D reconstruction. In addition, biomechanical properties, such as stiffness, compressive strength, and the elastic modulus of the 3D printed porous augment, were measured by means of a mechanical testing machine. Moreover, bone ingrowth and implant osseointegration were histomorphometrically assessed. Results. In terms of the inner structural parameters of the 3D printed porous augment, the porosity was 55.48 +/- 0.61%, pore size 319.23 +/- 25.05 mu m, and trabecular diameter 240.10 +/- 23.50 mu m. Biomechanically, the stiffness was 21464.60 +/- 1091.69 N/mm, compressive strength 231.10 +/- 11.77 MPa, and elastic modulus 5.35 +/- 0.23 GPa, respectively. Furthermore, the matching extent between the postoperative augment and the designed one was up to 91.40 +/- 2.83%. Besides, the maximal shear strength of the 3D printed augment was 929.46 +/- 295.99 N immediately after implantation, whereas the strength was 1521.93 +/- 98.38 N 12 weeks after surgery (p=0.0302). The bone mineral apposition rate (mu m per day) 12 weeks post operation was 3.77 +/- 0.93 mu m/d. The percentage bone volume of new bone was 22.30 +/- 4.51% 12 weeks after surgery. Conclusion. The 3D printed porous Ti6Al4V augment designed in this study was well biocompatible with bone tissue, possessed proper biomechanical features, and was anatomically well matched with the defect bone. Therefore, the 3D printed porous Ti6Al4V augment possesses great potential as an alternative for individualized treatment of severe acetabular bone defects.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Application of three-dimensional-printed porous tantalum cones in total knee arthroplasty revision to reconstruct bone defects
    Ao, Yunong
    Guo, Lin
    Chen, Hao
    He, Rui
    Yang, Pengfei
    Fu, Dejie
    Gu, Lingchuan
    Peng, Yang
    Xiong, Ran
    Yang, Liu
    Wang, Fuyou
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [32] Customized three dimensional printed prosthesis as a novel intercalary reconstruction for resection of extremity bone tumours: a retrospective cohort study
    Zhao Zhang
    Yubo Shi
    Jun Fu
    Dong Liu
    Dongze Zhu
    Xincheng Liu
    Jingyi Dang
    Hongbin Fan
    International Orthopaedics, 2022, 46 : 2971 - 2981
  • [33] Development of a new critical size defect model in the paranasal sinus and first approach for defect reconstruction-An in vivo maxillary bone defect study in sheep
    Rothweiler, R.
    Kuhn, S.
    Stark, T.
    Heinemann, S.
    Hoess, A.
    Fuessinger, M. A.
    Brandenburg, L. S.
    Roelz, R.
    Metzger, M. C.
    Hubbe, U.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2022, 33 (11)
  • [34] An accurate method of radiological assessment of acetabular abduction and anteversion angles in three-dimensional reconstruction of multi-slice spiral computed tomography
    Fan, Xin-Cheng
    Fan, Wen-Wen
    Wang, Feng-Yao
    Yu, Chun-Li
    Zhu, Hai-Tao
    Wei, Kai-Bin
    Ma, Zhen-Bo
    Liu, Feng
    MINERVA BIOTECNOLOGICA, 2017, 29 (01) : 41 - 49
  • [35] Investigation of the In Vitro and In Vivo Biocompatibility of a Three-Dimensional Printed Thermoplastic Polyurethane/Polylactic Acid Blend for the Development of Tracheal Scaffolds
    Abdul Samat, Asmak
    Abdul Hamid, Zuratul Ain
    Jaafar, Mariatti
    Ong, Chern Chung
    Yahaya, Badrul Hisham
    BIOENGINEERING-BASEL, 2023, 10 (04):
  • [36] Pore throat size and connectivity determine bone and tissue ingrowth into porous implants: Three-dimensional micro-CT based structural analyses of porous bioactive titanium implants
    Otsuki, Bungo
    Takemoto, Mitsuru
    Fujibayashi, Shunsuke
    Neo, Masashi
    Kokubo, Tadashi
    Nakamura, Takashi
    BIOMATERIALS, 2006, 27 (35) : 5892 - 5900
  • [37] Quantifying cortical bone water in vivo by three-dimensional ultra-short echo-time MRI
    Rad, Hamidreza Saligheh
    Lam, Shing Chun Benny
    Magland, Jeremy F.
    Ong, Henry
    Li, Cheng
    Song, Hee Kwon
    Love, James
    Wehrli, Felix W.
    NMR IN BIOMEDICINE, 2011, 24 (07) : 855 - 864
  • [38] Enhancing Distraction Osteogenesis With Carbon Fiber Reinforced Polyether Ether Ketone Bone Pins and a Three-Dimensional Printed Transfer Device to Permit Artifact-Free Three-Dimensional Magnetic Resonance Imaging
    Eley, Karen A.
    Moazen, Mehran
    Delso, Gaspar
    Javidan, Maryam
    Kaggie, Joshua
    Kalaskar, Deepak M.
    Knowles, Jonathan C.
    Owji, Nazanin
    Watt-Smith, Stephen R.
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (01) : 360 - 364
  • [39] Development of a synthetic tissue engineered three-dimensional printed bioceramic-based bone graft with homogenously distributed osteoblasts and mineralizing bone matrix in vitro
    Adel-Khattab, Doaa
    Giacomini, Francesca
    Gildenhaar, Renate
    Berger, Georg
    Gomes, Cynthia
    Linow, Ulf
    Hardt, Martin
    Peleska, Barbara
    Guenster, Jens
    Stiller, Michael
    Houshmand, Alireza
    Ghaffar, Khaled Abdel
    Gamal, Ahmed
    El-Mofty, Mohamed
    Knabe, Christine
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2018, 12 (01) : 44 - 58
  • [40] Acetabular defect reconstruction with impacted morsellized bone grafts or TCP/HA particles. A study on the mechanical stability of cemented cups in an artificial acetabulum model
    Bolder, SBT
    Verdonschot, N
    Schreurs, BW
    Buma, P
    BIOMATERIALS, 2002, 23 (03) : 659 - 666