Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus

被引:29
作者
Del Baldo, Francesca [1 ]
Canton, Claudia [1 ]
Testa, Silvia [1 ]
Swales, Harry [2 ]
Drudi, Ignazio [3 ]
Golinelli, Stefania [1 ]
Fracassi, Federico [1 ]
机构
[1] Univ Bologna, Dept Vet Med Sci, Via Tolara di Sopra 50, I-40064 Bologna, Italy
[2] Univ Liverpool, Small Anim Teaching Hosp, Leahurst Campus, Wirral, Merseyside, England
[3] Univ Bologna, Dept Stat Sci, Bologna, Italy
关键词
canine; diabetes mellitus; FreeStyle Libre; interstitial glucose; TO-DAY VARIATION; GLYCEMIC VARIABILITY; INTERSTITIAL GLUCOSE; SENSING TECHNOLOGY; GROWTH-HORMONE; REAL-LIFE; INSULIN; TYPE-1; HYPOGLYCEMIA; MULTICENTER;
D O I
10.1111/jvim.15930
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Flash glucose monitoring system (FGMS; FreeStyle Libre) was recently validated for use in diabetic dogs (DD). It is not known if this system is clinically useful in monitoring DD. Objective To compare the clinical utility of FGMS against blood glucose curves (BGCs) obtained with a portable blood glucose meter (PBGM) in monitoring DD. Animals Twenty dogs with diabetes mellitus. Methods Prospective study. Dogs with diabetes mellitus on insulin treatment for at least 1 month were included. Comparisons of insulin dose recommendations based on the in-hospital GCs acquired using FGMS and a PBGM, consecutive-day interstitial GCs (IGCs) acquired at home using the FGMS, and consecutive-day, home vs hospital IGCs acquired using the FGMS were made using concordance analysis. Results There was good concordance between insulin dose recommendations based on FGMS and PBGM generated GCs and IGCs obtained in the 2 different environments on 2 consecutive days, but almost absent concordance between IGCs obtained on 2 consecutive days at home. Glucose nadirs were detected in 34/43 (79%) of Ambulatory Glucose Profile (AGP) reports of the FGMS. In comparison, concordant glucose nadirs were identified in 14/34 (41%) BGCs using PBGM. The individual FGMS scans and PBGM identified 60% and 9% of low IG/hypoglycemic episodes, respectively. Conclusions and Clinical Importance Insulin dose adjustments based on BGCs can be suboptimal. The FGMS allows a more accurate identification of the glucose nadirs and hypoglycemic episodes compared to the use of a PBGM and assessment of day-to-day variations in glycemic control.
引用
收藏
页码:2296 / 2305
页数:10
相关论文
共 50 条
  • [41] Continuous blood glucose monitoring in diabetes treatment
    Vazeou, Andriani
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2011, 93 : S125 - S130
  • [42] Differences of FreeStyle Libre Flash Glucose Monitoring System and Finger Pricks on Clinical Characteristics and Glucose Monitoring Satisfactions in Type 1 Diabetes Using Insulin Pump
    Al Hayek, Ayman A.
    Robert, Asirvatham A.
    Al Dawish, Mohamed A.
    CLINICAL MEDICINE INSIGHTS-ENDOCRINOLOGY AND DIABETES, 2019, 12
  • [43] Flash Continuous Glucose Monitoring (FreeStyle Libre 14-Day System) for Self-Management of Diabetes Mellitus
    Choi, Hiu Ying Joanna
    AMERICAN FAMILY PHYSICIAN, 2021, 103 (11) : 688 - 690
  • [44] Flash forward: a review of flash glucose monitoring
    Leelarathna, L.
    Wilmot, E. G.
    DIABETIC MEDICINE, 2018, 35 (04) : 472 - 482
  • [45] Efficacy and safety comparison of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes
    Wojciechowski, Piotr
    Rys, Przemyslaw
    Lipowska, Anna
    Gaweska, Magdalena
    Malecki, Maciej T.
    POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ-POLISH ARCHIVES OF INTERNAL MEDICINE, 2011, 121 (10): : 333 - 343
  • [46] The value of Continuous Glucose Monitoring and Self-Monitoring of Blood Glucose in patients with Gestational Diabetes Mellitus during Ramadan fasting
    Afandi, Bachar
    Hassanein, Mohamed
    Roubi, Sana
    Nagelkerke, Nico
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2019, 151 : 260 - 264
  • [47] Metabolic control and satisfaction in a diabetes education programme in flash glucose monitoring through telemedicine in type 1 diabetes
    Marca, Maria de la O. Nieto
    Diaz-Soto, Gonzalo
    Ibanez, Marta Sanchez
    Simon, Sofia del Amo
    Velasco, Pablo Fernandez
    Torres, Beatriz Torres
    Gomez, Juan Jose Loepez
    Hoyos, Emilia Gomez
    Buigues, Ana Ortola
    Garcia, Esther Delgado
    Roman, Daniel de Luis
    ENDOCRINOLOGIA DIABETES Y NUTRICION, 2023, 70 (06): : 408 - 414
  • [48] Cost-effectiveness analysis of real-time continuous monitoring glucose compared to self-monitoring of blood glucose for diabetes mellitus in Spain
    Garcia-Lorenzo, Borja
    Rivero-Santana, Amado
    Vallejo-Torres, Laura
    Castilla-Rodriguez, Ivan
    Garcia-Perez, Sonia
    Garcia-Perez, Lidia
    Perestelo-Perez, Lilisbeth
    JOURNAL OF EVALUATION IN CLINICAL PRACTICE, 2018, 24 (04) : 772 - 781
  • [49] Flash Glucose Monitoring: The Future Is Here
    Garg, Satish K.
    Akturk, Halis Kaan
    DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 : S1 - S3
  • [50] Self-monitoring of blood glucose in diabetes: is it worth it?
    O'Kane, Maurice J.
    Pickup, John
    ANNALS OF CLINICAL BIOCHEMISTRY, 2009, 46 : 273 - 282