Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus

被引:29
|
作者
Del Baldo, Francesca [1 ]
Canton, Claudia [1 ]
Testa, Silvia [1 ]
Swales, Harry [2 ]
Drudi, Ignazio [3 ]
Golinelli, Stefania [1 ]
Fracassi, Federico [1 ]
机构
[1] Univ Bologna, Dept Vet Med Sci, Via Tolara di Sopra 50, I-40064 Bologna, Italy
[2] Univ Liverpool, Small Anim Teaching Hosp, Leahurst Campus, Wirral, Merseyside, England
[3] Univ Bologna, Dept Stat Sci, Bologna, Italy
关键词
canine; diabetes mellitus; FreeStyle Libre; interstitial glucose; TO-DAY VARIATION; GLYCEMIC VARIABILITY; INTERSTITIAL GLUCOSE; SENSING TECHNOLOGY; GROWTH-HORMONE; REAL-LIFE; INSULIN; TYPE-1; HYPOGLYCEMIA; MULTICENTER;
D O I
10.1111/jvim.15930
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Flash glucose monitoring system (FGMS; FreeStyle Libre) was recently validated for use in diabetic dogs (DD). It is not known if this system is clinically useful in monitoring DD. Objective To compare the clinical utility of FGMS against blood glucose curves (BGCs) obtained with a portable blood glucose meter (PBGM) in monitoring DD. Animals Twenty dogs with diabetes mellitus. Methods Prospective study. Dogs with diabetes mellitus on insulin treatment for at least 1 month were included. Comparisons of insulin dose recommendations based on the in-hospital GCs acquired using FGMS and a PBGM, consecutive-day interstitial GCs (IGCs) acquired at home using the FGMS, and consecutive-day, home vs hospital IGCs acquired using the FGMS were made using concordance analysis. Results There was good concordance between insulin dose recommendations based on FGMS and PBGM generated GCs and IGCs obtained in the 2 different environments on 2 consecutive days, but almost absent concordance between IGCs obtained on 2 consecutive days at home. Glucose nadirs were detected in 34/43 (79%) of Ambulatory Glucose Profile (AGP) reports of the FGMS. In comparison, concordant glucose nadirs were identified in 14/34 (41%) BGCs using PBGM. The individual FGMS scans and PBGM identified 60% and 9% of low IG/hypoglycemic episodes, respectively. Conclusions and Clinical Importance Insulin dose adjustments based on BGCs can be suboptimal. The FGMS allows a more accurate identification of the glucose nadirs and hypoglycemic episodes compared to the use of a PBGM and assessment of day-to-day variations in glycemic control.
引用
收藏
页码:2296 / 2305
页数:10
相关论文
共 50 条
  • [21] Evaluation of blood glucose fluctuation in Japanese patients with type 1 diabetes mellitus by self-monitoring of blood glucose and continuous glucose monitoring
    Kusunoki, Yoshiki
    Katsuno, Tomoyuki
    Nakae, Rie
    Watanabe, Kahori
    Akagami, Takafumi
    Ochi, Fumihiro
    Tokuda, Masaru
    Murai, Kazuki
    Miuchi, Masayuki
    Miyagawa, Jun-ichiro
    Namba, Mitsuyoshi
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2015, 108 (02) : 342 - 349
  • [22] Comparison of Glucose Fluctuations between Day- and Night-Time Measured Using a Continuous Glucose Monitoring System in Diabetic Dogs
    Mori, Akihiro
    Kurishima, Miyuki
    Oda, Hitomi
    Saeki, Kaori
    Arai, Toshiro
    Sako, Toshinori
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2013, 75 (01) : 113 - 117
  • [23] National Consensus in the Use of the Flash Glucose Monitoring System in Portugal
    Cardoso, Helena
    Carvalho, Davide
    Pape, Estevao
    Carrilho, Francisco
    Raposo, Joao Filipe
    Melo, Miguel
    Carvalho, Ema
    Duarte, Rui
    REVISTA PORTUGUESA DE ENDOCRINOLOGIA DIABETES E METABOLISMO, 2019, 14 (01) : 74 - 81
  • [24] Accuracy of flash glucose monitoring in insulin-treated patients with type 2 diabetes
    Sato, Tatsuya
    Oshima, Hiroto
    Nakata, Kei
    Kimura, Yukishige
    Yano, Toshiyuki
    Furuhashi, Masato
    Tanno, Masaya
    Miki, Takayuki
    Miura, Tetsuji
    JOURNAL OF DIABETES INVESTIGATION, 2019, 10 (03) : 846 - 850
  • [25] FLASH GLUCOSE MONITORING (FGM)
    Szewczyk, Alicja
    Tobiasz-Kalkun, Natasza
    Stefanowicz-Bielska, Anna
    Kobos, Ewa
    Mtynarczuk, Miroslawa
    Kapusciok, Justyna
    Michalowska, Jolanta
    PIELEGNIARSTWO XXI WIEKU-NURSING IN THE 21 CENTURY, 2020, 19 (03): : 189 - 190
  • [26] Validation of a flash glucose monitoring system in outpatient diabetic cats
    Shea, Emily K.
    Hess, Rebecka S.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (04) : 1703 - 1712
  • [27] Importance of continuous glucose monitoring in the treatment of diabetes mellitus
    Moon, Sun Joon
    Lee, Won-Young
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2023, 66 (07): : 432 - 438
  • [28] Impact of flash glucose monitoring on glucose control and hospitalization in type 1 diabetes: A nationwide cohort study
    Tsur, Anat
    Cahn, Avivit
    Israel, Meirav
    Feldhamer, Ilan
    Hammerman, Ariel
    Pollack, Rena
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2021, 37 (01)
  • [29] Clinical Performance of Flash Glucose Monitoring System in Patients with Liver Cirrhosis and Diabetes Mellitus
    Costa, Dalila
    Lourenco, Joana
    Monteiro, Ana Margarida
    Castro, Beatriz
    Oliveira, Patricia
    Tinoco, Maria Carmo
    Fernandes, Vera
    Marques, Olinda
    Goncalves, Raquel
    Rolanda, Carla
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [30] Flash Glucose Monitoring: A Review of the Literature with a Special Focus on Type 1 Diabetes
    Mancini, Giulia
    Berioli, Maria Giulia
    Santi, Elisa
    Rogari, Francesco
    Toni, Giada
    Tascini, Giorgia
    Crispoldi, Roberta
    Ceccarini, Giulia
    Esposito, Susanna
    NUTRIENTS, 2018, 10 (08)