Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus

被引:29
|
作者
Del Baldo, Francesca [1 ]
Canton, Claudia [1 ]
Testa, Silvia [1 ]
Swales, Harry [2 ]
Drudi, Ignazio [3 ]
Golinelli, Stefania [1 ]
Fracassi, Federico [1 ]
机构
[1] Univ Bologna, Dept Vet Med Sci, Via Tolara di Sopra 50, I-40064 Bologna, Italy
[2] Univ Liverpool, Small Anim Teaching Hosp, Leahurst Campus, Wirral, Merseyside, England
[3] Univ Bologna, Dept Stat Sci, Bologna, Italy
关键词
canine; diabetes mellitus; FreeStyle Libre; interstitial glucose; TO-DAY VARIATION; GLYCEMIC VARIABILITY; INTERSTITIAL GLUCOSE; SENSING TECHNOLOGY; GROWTH-HORMONE; REAL-LIFE; INSULIN; TYPE-1; HYPOGLYCEMIA; MULTICENTER;
D O I
10.1111/jvim.15930
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Flash glucose monitoring system (FGMS; FreeStyle Libre) was recently validated for use in diabetic dogs (DD). It is not known if this system is clinically useful in monitoring DD. Objective To compare the clinical utility of FGMS against blood glucose curves (BGCs) obtained with a portable blood glucose meter (PBGM) in monitoring DD. Animals Twenty dogs with diabetes mellitus. Methods Prospective study. Dogs with diabetes mellitus on insulin treatment for at least 1 month were included. Comparisons of insulin dose recommendations based on the in-hospital GCs acquired using FGMS and a PBGM, consecutive-day interstitial GCs (IGCs) acquired at home using the FGMS, and consecutive-day, home vs hospital IGCs acquired using the FGMS were made using concordance analysis. Results There was good concordance between insulin dose recommendations based on FGMS and PBGM generated GCs and IGCs obtained in the 2 different environments on 2 consecutive days, but almost absent concordance between IGCs obtained on 2 consecutive days at home. Glucose nadirs were detected in 34/43 (79%) of Ambulatory Glucose Profile (AGP) reports of the FGMS. In comparison, concordant glucose nadirs were identified in 14/34 (41%) BGCs using PBGM. The individual FGMS scans and PBGM identified 60% and 9% of low IG/hypoglycemic episodes, respectively. Conclusions and Clinical Importance Insulin dose adjustments based on BGCs can be suboptimal. The FGMS allows a more accurate identification of the glucose nadirs and hypoglycemic episodes compared to the use of a PBGM and assessment of day-to-day variations in glycemic control.
引用
收藏
页码:2296 / 2305
页数:10
相关论文
共 50 条
  • [1] Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations
    Howard, Leigh A.
    Lidbury, Jonathan A.
    Jeffe, Nicholas
    Washburn, Shannon E.
    Patterson, Carly A.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (06) : 2628 - 2635
  • [2] Comparison of an Intermittently Scanned (Flash) Continuous Glucose Monitoring System to Standard Self-Monitoring of Capillary Blood Glucose in Gestational Diabetes Mellitus
    Hussain, Farrah N.
    Raymond, Samantha
    Feldman, Kristina M.
    Scarpelli-Shchur, Sophia
    Strauss, Tirtza S.
    Al-Ibraheemi, Zainab
    Brustman, Lois
    AMERICAN JOURNAL OF PERINATOLOGY, 2023, 40 (11) : 1149 - 1157
  • [3] Assessment of postprandial hyperglycemia and circadian fluctuation of glucose concentrations in diabetic dogs using a flash glucose monitoring system
    Shea, Emily K.
    Hess, Rebecka S.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (02) : 843 - 852
  • [4] Accuracy of Flash Glucose Monitoring in Patients with Diabetes Mellitus on Hemodialysis and Its Relationship with Hydration Status
    Genua, Idoia
    Sanchez-Hernandez, Joan
    Jose Martinez, Maria
    Pujol, Isabel
    Places, Jaume
    Gonzalez, Carmen
    Martinez, Esther
    Manuel Diaz, Juan
    Chico, Ana
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (06): : 1308 - 1312
  • [5] Comparison of accuracy between flash glucose monitoring and continuous glucose monitoring in patients with type 2 diabetes mellitus undergoing hemodialysis
    Matoba, Kenta
    Hayashi, Akinori
    Shimizu, Naoya
    Moriguchi, Ibuki
    Kobayashi, Naoyuki
    Shichiri, Masayoshi
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2020, 34 (11)
  • [6] Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis
    Malerba, Eleonora
    Cattani, Chiara
    Del Baldo, Francesca
    Carotenuto, Gaia
    Corradini, Sara
    Golinelli, Stefania
    Drudi, Ignazio
    Fracassi, Federico
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2020, 34 (01) : 83 - 91
  • [7] Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs
    Corradini, S.
    Pilosio, B.
    Dondi, F.
    Linari, G.
    Testa, S.
    Brugnoli, F.
    Gianella, P.
    Pietra, M.
    Fracassi, F.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2016, 30 (04): : 983 - 988
  • [8] Glucose Awareness to Motivate and Enable Solutions (GAMES) in diabetes mellitus using flash glucose monitoring: A clinical programme
    Yeoh, Ester
    Png, Doanna
    Koh, Pei Ling
    Sum, Chee Fang
    Lim, Su Chi
    Tan, Hwee Huan
    Ubeynarayana, Chalani Udhyami
    Subramaniam, Tavintharan
    DIABETIC MEDICINE, 2022, 39 (01)
  • [9] Flash glucose monitoring in type 1 diabetes: A comparison with self-monitoring blood glucose
    Babaya, Naru
    Noso, Shinsuke
    Hiromine, Yoshihisa
    Taketomo, Yasunori
    Niwano, Fumimaru
    Yoshida, Sawa
    Yasutake, Sara
    Kawabata, Yumiko
    Ikegami, Hiroshi
    JOURNAL OF DIABETES INVESTIGATION, 2020, 11 (05) : 1222 - 1229
  • [10] Evaluation of a flash glucose monitoring system in dogs with diabetic ketoacidosis
    Silva, D. D.
    Cecci, G. R. M.
    Biz, G.
    Chiaro, F. N.
    Zanutto, M. S.
    DOMESTIC ANIMAL ENDOCRINOLOGY, 2021, 74