Energy- and time-resolved detection of prompt gamma-rays for proton range verification

被引:100
作者
Verburg, Joost M. [1 ,2 ,3 ]
Riley, Kent [1 ,2 ]
Bortfeld, Thomas [1 ,2 ]
Seco, Joao [1 ,2 ]
机构
[1] Harvard Univ, Sch Med, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Boston, MA 02114 USA
[3] Eindhoven Univ Technol, Sch Med Phys & Engn, NL-5600 MB Eindhoven, Netherlands
关键词
CROSS-SECTIONS RELEVANT; BEAM; THERAPY; RADIOTHERAPY; IRRADIATION; SIMULATION; ASTRONOMY; PATIENT; CAMERA; CARBON;
D O I
10.1088/0031-9155/58/20/L37
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this work, we present experimental results of a novel prompt gamma-ray detector for proton beam range verification. The detection system features an actively shielded cerium-doped lanthanum(III) bromide scintillator, coupled to a digital data acquisition system. The acquisition was synchronized to the cyclotron radio frequency to separate the prompt gamma-ray signals from the later-arriving neutron-induced background. We designed the detector to provide a high energy resolution and an effective reduction of background events, enabling discrete proton-induced prompt gamma lines to be resolved. Measuring discrete prompt gamma lines has several benefits for range verification. As the discrete energies correspond to specific nuclear transitions, the magnitudes of the different gamma lines have unique correlations with the proton energy and can be directly related to nuclear reaction cross sections. The quantification of discrete gamma lines also enables elemental analysis of tissue in the beam path, providing a better prediction of prompt gamma-ray yields. We present the results of experiments in which a water phantom was irradiated with proton pencil-beams in a clinical proton therapy gantry. A slit collimator was used to collimate the prompt gamma-rays, and measurements were performed at 27 positions along the path of proton beams with ranges of 9, 16 and 23 g cm(-2) in water. The magnitudes of discrete gamma lines at 4.44, 5.2 and 6.13 MeV were quantified. The prompt gamma lines were found to be clearly resolved in dimensions of energy and time, and had a reproducible correlation with the proton depth-dose curve. We conclude that the measurement of discrete prompt gamma-rays for in vivo range verification of clinical proton beams is feasible, and plan to further study methods and detector designs for clinical use.
引用
收藏
页码:L37 / L49
页数:13
相关论文
共 23 条
[1]   γ-ray production by proton and α-particle induced reactions on 12C, 16O, 24Mg, and Fe [J].
Belhout, A. ;
Kiener, J. ;
Coc, A. ;
Duprat, J. ;
Engrand, C. ;
Fitoussi, C. ;
Gounelle, M. ;
Lefebvre-Schuhl, A. ;
de Sereville, N. ;
Tatischeff, V. ;
Thibaud, J. -P. ;
Chabot, M. ;
Hammache, F. ;
Benhabiles-Mezhoud, H. .
PHYSICAL REVIEW C, 2007, 76 (03)
[2]   Measurements of nuclear γ-ray line emission in interactions of protons and α particles with N, O, Ne, and Si [J].
Benhabiles-Mezhoud, H. ;
Kiener, J. ;
Thibaud, J-P ;
Tatischeff, V. ;
Deloncle, I. ;
Coc, A. ;
Duprat, J. ;
Hamadache, C. ;
Lefebvre-Schuhl, A. ;
Dalouzy, J-C ;
de Grancey, F. ;
de Oliveira, F. ;
Dayras, F. ;
de Sereville, N. ;
Pellegriti, M-G ;
Lamia, L. ;
Ouichaoui, S. .
PHYSICAL REVIEW C, 2011, 83 (02)
[3]   Time-of-flight neutron rejection to improve prompt gamma imaging for proton range verification: a simulation study [J].
Biegun, Aleksandra K. ;
Seravalli, Enrica ;
Lopes, Patricia Cambraia ;
Rinaldi, Ilaria ;
Pinto, Marco ;
Oxley, David C. ;
Dendooven, Peter ;
Verhaegen, Frank ;
Parodi, Katia ;
Crespo, Paulo ;
Schaart, Dennis R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (20) :6429-6444
[4]   Golden beam data for proton pencil-beam scanning [J].
Clasie, Benjamin ;
Depauw, Nicolas ;
Fransen, Maurice ;
Goma, Carles ;
Panahandeh, Hamid Reza ;
Seco, Joao ;
Flanz, Jacob B. ;
Kooy, Hanne M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05) :1147-1158
[5]   Suppression of random coincidences during in-beam PET measurements at ion beam radiotherapy facilities [J].
Crespo, P ;
Barthel, T ;
Frais-Kölbl, H ;
Griesmayer, E ;
Heidel, K ;
Parodi, K ;
Pawelke, J ;
Enghardt, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) :980-987
[6]  
DYER P, 1981, PHYS REV C, V23, P1865, DOI 10.1103/PhysRevC.23.1865
[7]   Levenberg-Marquardt methods with strong local convergence properties for solving nonlinear equations with convex constraints [J].
Kanzow, C ;
Yamashita, N ;
Fukushima, T .
JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2004, 172 (02) :375-397
[8]   γ-ray production by inelastic proton scattering on 16O and 12C [J].
Kiener, J ;
Berheide, M ;
Achouri, NL ;
Boughrara, A ;
Coc, A ;
Lefebvre, A ;
Santos, FDO ;
Vieu, C .
PHYSICAL REVIEW C, 1998, 58 (04) :2174-2179
[9]   Systematic analysis of biological and physical limitations of proton beam range verification with offline PET/CT scans [J].
Knopf, A. ;
Parodi, K. ;
Bortfeld, T. ;
Shih, H. A. ;
Paganetti, H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (14) :4477-4495
[10]   CROSS-SECTIONS FOR PRODUCTION OF THE 15.10-MEV AND OTHER ASTROPHYSICALLY SIGNIFICANT GAMMA-RAY LINES THROUGH EXCITATION AND SPALLATION OF C-12 AND O-16 WITH PROTONS [J].
LANG, FL ;
WERNTZ, CW ;
CRANNELL, CJ ;
TROMBKA, JI ;
CHANG, CC .
PHYSICAL REVIEW C, 1987, 35 (04) :1214-1227