Cerebral Aneurysms: Accuracy of 320-Detector Row Nonsubtracted and Subtracted Volumetric CT Angiography for Diagnosis

被引:17
作者
Chen, Wenhua [1 ]
Xing, Wei [2 ]
Peng, Ya [3 ]
He, Zhongming [1 ]
Wang, Caoye [1 ]
Wang, Qi [1 ]
机构
[1] Suzhou Univ, Affiliated Hosp 3, Dept Intervent Radiol, Changzhou 213003, Peoples R China
[2] Suzhou Univ, Affiliated Hosp 3, Dept Radiol, Changzhou 213003, Peoples R China
[3] Suzhou Univ, Affiliated Hosp 3, Dept Neurosurg, Changzhou 213003, Peoples R China
关键词
COMPUTED TOMOGRAPHIC ANGIOGRAPHY; INTRACRANIAL ANEURYSMS; DIGITAL-SUBTRACTION; POSTOPERATIVE EVALUATION; SUBARACHNOID HEMORRHAGE; MULTISLICE CT; DSA;
D O I
10.1148/radiol.13130191
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the accuracy of 320-detector row nonsubtracted and subtracted volumetric computed tomographic (CT) angiography for detection of cerebral aneurysms. Materials and Methods: After institutional review board approval and informed written consent were obtained, 282 consecutive patients suspected of having cerebral aneurysms underwent CT angiography with a 320-detector row volumetric CT scanner and three-dimensional (3D) rotational digital subtraction angiography (DSA). The sensitivity, specificity, and accuracy of nonsubtracted and subtracted volumetric CT angiography for depiction of aneurysms were analyzed, with 3D DSA as the reference standard. P values less than .05 were considered to indicate a significant difference. Results: Among the 282 patients, 198 (70.2%) had 239 cerebral aneurysms that were detected on the basis of 3D DSA. Non-subtracted volumetric CT angiography showed 231 of the 239 (96.7%) aneurysms. The primary reason for missed aneurysms was close proximity to bone tissue. Sensitivity, specificity, and accuracy of nonsubtracted volumetric CT angiography for depicting aneurysms were 96.7%, 100%, and 97.5%, respectively, on a per-aneurysm basis. Subtracted volumetric CT angiography showed 237 of 239 (99.2%) aneurysms. Sensitivity, specificity, and accuracy of subtracted volumetric CT angiography for depicting aneurysms were 99.2%, 100%, and 99.4%, respectively, on a per-aneurysm basis. There was no statistically significant difference in accuracy between subtracted volumetric CT angiography and 3D DSA (P = .500). However, nonsubtracted volumetric CT angiography was significantly less sensitive than 3D DSA and subtracted volumetric CT angiography (P = .031 and .008, respectively). Conclusion: Subtracted 320-detector row volumetric CT angiography provides excellent sensitivity for detection of cerebral aneurysms and should be the first-line imaging technique for the noninvasive evaluation of aneurysms. The accuracy of nonsubtracted volumetric CT angiography was lower than that for subtracted volumetric CT angiography, especially for aneurysms adjacent to bone tissue. (C)RSNA, 2013
引用
收藏
页码:841 / 849
页数:9
相关论文
共 25 条
[11]  
Jayaraman MV, 2010, NO RADIOLOGY, V254, P315
[12]  
Jayaraman MV, 2010, NO RADIOLOGY, V254, P314
[13]   Death by nondiagnosis: Why emergent CT angiography should not be done for patients with subarachnoid Hemorrhage [J].
Kallmes, David F. ;
Marx, William F. ;
Tong, Frank .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (10) :1837-1838
[14]   Evaluation of 64-Section CT Angiography for Detection and Treatment Planning of Intracranial Aneurysms by Using DSA and Surgical Findings [J].
Li, Qi ;
Lv, Fajin ;
Li, Yongmei ;
Luo, Tianyou ;
Li, Kewei ;
Xie, Peng .
RADIOLOGY, 2009, 252 (03) :808-815
[15]   Digital Subtraction CT Angiography for Detection of Intracranial Aneurysms: Comparison with Three-dimensional Digital Subtraction Angiography [J].
Lu, Li ;
Zhang, Long Jiang ;
Poon, Colin S. ;
Wu, Sheng Yong ;
Zhou, Chang Sheng ;
Luo, Song ;
Wang, Mei ;
Lu, Guang Ming .
RADIOLOGY, 2012, 262 (02) :605-612
[16]   Comparison of the accuracy of subtraction CT angiography performed on 320-detector row volume CT with conventional CT angiography for diagnosis of intracranial aneurysms [J].
Luo, Zhuren ;
Wang, Dan ;
Sun, Xilin ;
Zhang, Tong ;
Liu, Fang ;
Dong, Dandan ;
Chan, Nicholas K. ;
Shen, Baozhong .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (01) :118-122
[17]   Detection of aneurysms by 64-section multidetector CT angiography in patients acutely suspected of having an intracranial aneurysm and comparison with digital subtraction and 3D rotational angiography [J].
McKinney, A. M. ;
Palmer, C. S. ;
Truwit, C. L. ;
Karagulle, A. ;
Teksam, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (03) :594-602
[18]   Aneurysmal Subarachnoid Hemorrhage: DSA versus CT Angiography-Is the Answer Available? [J].
Moran, Christopher J. .
RADIOLOGY, 2011, 258 (01) :15-17
[19]   Comparison of Standard- and Low-Tube Voltage 320-Detector Row Volume CT Angiography in Detection of Intracranial Aneurysms with Digital Subtraction Angiography as Gold Standard [J].
Sun, Gang ;
Ding, Juan ;
Lu, Yang ;
Li, Min ;
Li, Li ;
Li, Guo-ying ;
Zhang, Xu-ping .
ACADEMIC RADIOLOGY, 2012, 19 (03) :281-288
[20]   METHODS OF REPORTING STATISTICAL RESULTS FROM MEDICAL-RESEARCH STUDIES [J].
WALTER, SD .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1995, 141 (10) :896-906