Cerebral Aneurysms: Accuracy of 320-Detector Row Nonsubtracted and Subtracted Volumetric CT Angiography for Diagnosis

被引:17
作者
Chen, Wenhua [1 ]
Xing, Wei [2 ]
Peng, Ya [3 ]
He, Zhongming [1 ]
Wang, Caoye [1 ]
Wang, Qi [1 ]
机构
[1] Suzhou Univ, Affiliated Hosp 3, Dept Intervent Radiol, Changzhou 213003, Peoples R China
[2] Suzhou Univ, Affiliated Hosp 3, Dept Radiol, Changzhou 213003, Peoples R China
[3] Suzhou Univ, Affiliated Hosp 3, Dept Neurosurg, Changzhou 213003, Peoples R China
关键词
COMPUTED TOMOGRAPHIC ANGIOGRAPHY; INTRACRANIAL ANEURYSMS; DIGITAL-SUBTRACTION; POSTOPERATIVE EVALUATION; SUBARACHNOID HEMORRHAGE; MULTISLICE CT; DSA;
D O I
10.1148/radiol.13130191
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the accuracy of 320-detector row nonsubtracted and subtracted volumetric computed tomographic (CT) angiography for detection of cerebral aneurysms. Materials and Methods: After institutional review board approval and informed written consent were obtained, 282 consecutive patients suspected of having cerebral aneurysms underwent CT angiography with a 320-detector row volumetric CT scanner and three-dimensional (3D) rotational digital subtraction angiography (DSA). The sensitivity, specificity, and accuracy of nonsubtracted and subtracted volumetric CT angiography for depiction of aneurysms were analyzed, with 3D DSA as the reference standard. P values less than .05 were considered to indicate a significant difference. Results: Among the 282 patients, 198 (70.2%) had 239 cerebral aneurysms that were detected on the basis of 3D DSA. Non-subtracted volumetric CT angiography showed 231 of the 239 (96.7%) aneurysms. The primary reason for missed aneurysms was close proximity to bone tissue. Sensitivity, specificity, and accuracy of nonsubtracted volumetric CT angiography for depicting aneurysms were 96.7%, 100%, and 97.5%, respectively, on a per-aneurysm basis. Subtracted volumetric CT angiography showed 237 of 239 (99.2%) aneurysms. Sensitivity, specificity, and accuracy of subtracted volumetric CT angiography for depicting aneurysms were 99.2%, 100%, and 99.4%, respectively, on a per-aneurysm basis. There was no statistically significant difference in accuracy between subtracted volumetric CT angiography and 3D DSA (P = .500). However, nonsubtracted volumetric CT angiography was significantly less sensitive than 3D DSA and subtracted volumetric CT angiography (P = .031 and .008, respectively). Conclusion: Subtracted 320-detector row volumetric CT angiography provides excellent sensitivity for detection of cerebral aneurysms and should be the first-line imaging technique for the noninvasive evaluation of aneurysms. The accuracy of nonsubtracted volumetric CT angiography was lower than that for subtracted volumetric CT angiography, especially for aneurysms adjacent to bone tissue. (C)RSNA, 2013
引用
收藏
页码:841 / 849
页数:9
相关论文
共 25 条
[1]   Acute subarachnoid hemorrhage: using 64-slice multidetector CT angiography to "triage" patients' treatment [J].
Agid, R. ;
Lee, S. K. ;
Willinsky, R. A. ;
Farb, R. I. ;
terBrugge, K. G. .
NEURORADIOLOGY, 2006, 48 (11) :787-794
[2]   The surgical treatment of intracranial aneurysms based on computer Tomographic angiography alone - streamlining the acute management of symptomatic aneurysms [J].
Boet, R ;
Poon, WS ;
Lam, JMK ;
Yu, SCH .
ACTA NEUROCHIRURGICA, 2003, 145 (02) :101-105
[3]   Sixteen-row multislice computerized tomography angiography in the postoperative evaluation of patients with intracranial aneurysms [J].
Chen, W. ;
Yang, Y. ;
Qiu, J. ;
Peng, Y. ;
Xing, W. .
BRITISH JOURNAL OF NEUROSURGERY, 2008, 22 (01) :63-70
[4]   Accuracy of 16-row multislice computed tomographic angiography for assessment of small cerebral aneurysms [J].
Chen, Wenhua ;
Wang, Jie ;
Xin, Wei ;
Peng, Ya ;
Xu, Qing .
NEUROSURGERY, 2008, 62 (01) :113-121
[5]   Clinical application of 16-row multislice computed tomographic angiography in the preoperative and postoperative evaluation of intracranial aneurysms for surgical clipping [J].
Chen, Wenhua ;
Yang, Yilin ;
Qiu, Jianguo ;
Peng, Ya ;
Xing, Wei .
SURGICAL NEUROLOGY, 2009, 71 (05) :559-565
[6]   Accuracy of 16-row multislice computerized tomography angiography for assessment of intracranial aneurysms [J].
Chen, Wenhua ;
Wang, Jie ;
Xing, Wei ;
Xu, Qing ;
Qiu, Jianguo ;
Huang, Qingjuan ;
Sun, Yifang ;
Yu, Shengnan ;
Peng, Ya .
SURGICAL NEUROLOGY, 2009, 71 (01) :32-42
[7]   Detection of intracranial aneurysms with multislice CT: comparison with conventional angiography [J].
Dammert, S ;
Krings, T ;
Moller-Hartmann, W ;
Ueffing, E ;
Hans, FJ ;
Willmes, K ;
Mull, M ;
Thron, A .
NEURORADIOLOGY, 2004, 46 (06) :427-434
[8]   Current Imaging Assessment and Treatment of Intracranial Aneurysms [J].
Hacein-Bey, Lotfi ;
Provenzale, James M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (01) :32-44
[9]   Detection of Pulsation in Ruptured and Unruptured Cerebral Aneurysms by Electrocardiographically Gated 3-Dimensional Computed Tomographic Angiography With a 320-Row Area Detector Computed Tomography and Evaluation of Its Clinical Usefulness [J].
Hayakawa, Motoharu ;
Maeda, Shingo ;
Sadato, Akiyo ;
Tanaka, Teppei ;
Kaito, Takafumi ;
Hattori, Natsuki ;
Ganaha, Tsukasa ;
Moriya, Shigeta ;
Katada, Kazuhiro ;
Murayama, Kazuhiro ;
Kato, Yoko ;
Hirose, Yuichi .
NEUROSURGERY, 2011, 69 (04) :843-851
[10]   Results of a prospective protocol of computed tomographic angiography in place of catheter angiography as the only diagnostic and pretreatment planning study for cerebral aneurysms by a combined neurovascular team [J].
Hoh, BL ;
Cheung, AC ;
Rabinov, JD ;
Pryor, JC ;
Carter, BS ;
Ogilvy, CS .
NEUROSURGERY, 2004, 54 (06) :1329-1340