Operation of Stand-Alone Microgrids Considering the Load Following of Biomass Power Plants and the Power Curtailment Control Optimization of Wind Turbines

被引:24
作者
Zhou, Zhichao [1 ,2 ]
Wang, Chengshan [1 ]
Ge, Leijiao [1 ]
机构
[1] Tianjin Univ, Minist Educ, Key Lab Smart Grid, Tianjin 300072, Peoples R China
[2] CITIC Financial Leasing Co Ltd, Beijing 100020, Peoples R China
基金
中国国家自然科学基金;
关键词
Stand-alone microgrid; biomass power plant; load follow; wind power curtailment control; energy management and dispatch; emergency power control; ALGORITHM-BASED OPTIMIZATION; ENERGY MANAGEMENT; HYBRID; DESIGN; SYSTEM; DISPATCH; STORAGE;
D O I
10.1109/ACCESS.2019.2958678
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Various stand-alone hybrid power systems are widely used to fulfil the electric loads for remote, rural villages. Although there are many investigations based on various aspects of renewable hybrids energy microgrids, the discussions about the application of biomass combustion power plants are rare. Also, detailed investigations of the system steady and transient stability analysis, and the power curtailment control optimization of wind turbines in these stand-alone hybrid systems are seldom found. This paper focuses on wind/biomass/diesel/battery stand-alone microgrids and discusses the system operation, energy management and dispatch issues detailed. The renewable and controllable biomass power is localized to follow the load fluctuations over a long timescale to decrease the power production from diesel and the peak-load shifting demands of the battery banks. An optimization strategy of the wind power curtailment control is also proposed to effectively decrease the frequency and amplitude of the pitch actor and, to some extent, improve the power generation through the combination of the active turbine speed control and pitch regulation. Then a parallel double-mode optimal operation strategy with a fault detector is presented to realize economic optimization dispatch under the normal mode and emergency power control for large disturbance scenarios. Finally, case studies of a microgrid on a remote Canadian aboriginal community are conducted to demonstrate the performance of the proposed methods.
引用
收藏
页码:186115 / 186125
页数:11
相关论文
共 30 条
[1]  
[Anonymous], 2003, GE POWER SYST ENERGY
[2]  
[Anonymous], 2012, 2012 IEEE POW EN SOC, DOI DOI 10.1109/PESGM.2012.6343975
[3]  
[Anonymous], 2012, GENERATION CLEAN REN
[4]  
[Anonymous], 2009, P 17 EUR BIOM C HAMB
[5]  
Ashok S, 2007, 2007 IEEE CAN EL POW, P371, DOI [10.1109/EPC.2007.4520360, DOI 10.1109/EPC.2007.4520360]
[6]  
Barley CD, 1996, SOL ENERGY, V58, P165
[7]   A Multiagent-Based Hierarchical Energy Management Strategy for Multi-Microgrids Considering Adjustable Power and Demand Response [J].
Bui, Van-Hai ;
Hussain, Akhtar ;
Kim, Hak-Man .
IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (02) :1323-1333
[8]   Strategies for Operating Wind Power in a Similar Manner of Conventional Power Plant [J].
Chang-Chien, Le-Ren ;
Yin, Yao-Ching .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (04) :926-934
[9]   Multi-agent System Based Energy Management Strategies for Microgrid by using Renewable Energy Source and Load Forecasting [J].
Dou, Chun-xia ;
An, Xiao-gang ;
Yue, Dong .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (18) :2059-2072
[10]   A hybrid algorithm based optimization on modeling of grid independent biodiesel-based hybrid solar/wind systems [J].
Du Guangqian ;
Bekhrad, Kaveh ;
Azarikhah, Pouria ;
Maleki, Akbar .
RENEWABLE ENERGY, 2018, 122 :551-560