The effect of high-dose-rate brachytherapy dwell sequence on cell survival

被引:13
作者
Arnfield, MR
Lin, PS
Manning, MA
Arthur, DW
Kavanagh, BD
Zwicker, RD
Schmidt-Ullrich, RK
机构
[1] Virginia Commonwealth Univ, Coll Med, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] McGuire VA Hosp, Richmond, VA USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 52卷 / 03期
关键词
high-dose-rate brachytherapy; dose rate; radiation; V79; cells; radioresistance;
D O I
10.1016/S0360-3016(01)02722-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: During a high-dose-rate (HDR) brachytherapy treatment, as the source steps through different dwell positions, the dose rate at any fixed point within the implant varies, because the distance between the point and the source continually changes. The instantaneous dose rate may vary by a factor of 100 or more, in a complex dwell position sequence. Two different points which receive the same total dose may have received that dose with a very different sequence of dose rates. Any effects due to the complex changes in dose rate, including the sequence of dose delivery, are ignored. We investigated the possible effects of the sequence in which dose is delivered at two different dose rates, representative of dose rates that occur during an HDR treatment. Methods and Materials: The target consisted of a tube containing a 1.0 cm(-3) suspension of V-79 Chinese hamster cells. Two fixed source dwell positions near and far from the target, representing high and intermediate dose rates, were considered. The experiments compared the survival of V-79 cells exposed to an irradiation sequence consisting of either an HDR component followed by an intermediate-dose-rate component (H-I arm), or the reverse (I-H arm). In either case, the total dose and the dose ratio were the same, only the order in which the high-or intermediate-dose-rate components of the dose were delivered was changed. Results: When the intermediate-dose-rate component was given before the HDR component, there was increased survival. All data pairs from three experiments showed greater survival for the I-H arm than the H-I arm by amounts ranging from 4% to 24%. Simple linear-quadratic models such as the Lea-Catchside model, which is invariant to time reversal of irradiation sequence, do not predict these results. Conclusions: These results suggest that targets receiving the same total dose of radiation during an HDR implant may not experience the same biological effect. This may be related to induced radioresistance or sublethal damage repair. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:850 / 857
页数:8
相关论文
共 13 条
  • [1] DOSE-RATE EFFECTS BETWEEN 0.3 AND 30 GY/H IN A NORMAL AND A MALIGNANT HUMAN CELL-LINE
    AMDUR, RJ
    BEDFORD, JS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (01): : 83 - 90
  • [2] CONDITIONS FOR THE EQUIVALENCE OF CONTINUOUS TO PULSED LOW-DOSE RATE BRACHYTHERAPY
    BRENNER, DJ
    HALL, EJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (01): : 181 - 190
  • [3] GLASGLOW GP, 1993, 41 AAPM TASK GROUP
  • [4] THE KINETICS OF CELLULAR-RECOVERY IN EXPONENTIAL AND PLATEAU GROWTH-PHASE HUMAN GLIOMA-CELLS FOLLOWING GAMMA-IRRADIATION
    HELLER, DP
    RAAPHORST, GP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (02): : 383 - 390
  • [5] *INT COMM RAD UN M, 1985, ICRU38
  • [6] Biologic treatment planning for high-dose-rate brachytherapy
    Manning, MA
    Zwicker, RD
    Arthur, DW
    Arnfield, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03): : 839 - 845
  • [7] Interstitial high-dose-rate brachytherapy boost: The feasibility and cosmetic outcome of a fractionated outpatient delivery scheme
    Manning, PA
    Arthur, DW
    Schmidt-Ullrich, RK
    Arnfield, MR
    Amir, C
    Zwicker, RD
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05): : 1301 - 1306
  • [8] THE RESPONSE OF CHINESE-HAMSTER V79 CELLS TO LOW RADIATION-DOSES - EVIDENCE OF ENHANCED SENSITIVITY OF THE WHOLE CELL-POPULATION
    MARPLES, B
    JOINER, MC
    [J]. RADIATION RESEARCH, 1993, 133 (01) : 41 - 51
  • [9] THE ELIMINATION OF LOW-DOSE HYPERSENSITIVITY IN CHINESE-HAMSTER V79-379A CELLS BY PRETREATMENT WITH X-RAYS OR HYDROGEN-PEROXIDE
    MARPLES, B
    JOINER, MC
    [J]. RADIATION RESEARCH, 1995, 141 (02) : 160 - 169
  • [10] EFFECTIVE ATTENUATION IN WATER OF GAMMA RAYS OF GOLD 198 IRIDIUM 192 CESIUM 137 RADIUM 226 AND COBALT 60
    MEISBERGER, LL
    KELLER, RJ
    SHALEK, RJ
    [J]. RADIOLOGY, 1968, 90 (05) : 953 - +