Electrochemical multianalyte immunoassays using an array-based sensor

被引:134
作者
Wilson, MS [1 ]
Nie, WY [1 ]
机构
[1] EIC Labs Inc, Norwood, MA 02062 USA
关键词
D O I
10.1021/ac0518452
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amperometric biosensor for performing simultaneous electrochemical multianalyte immunoassays is described. The sensor consisted of eight iridium oxide sensing electrodes (0.78 mm(2) each), an iridium counter electrode, and a Ag/AgCl reference electrode patterned on a glass substrate. Four different capture antibodies were immobilized on the sensing electrodes via adsorption. Quantification of proteins was achieved using an ELISA in which the electrochemical oxidation of enzyme-generated hydroquinone was measured. The spatial separation of the electrodes enabled simultaneous electrochemical immunoassays for multiple proteins to be conducted in a single assay without amperometric crosstalk between the electrodes. The simultaneous detection of goat IgG, mouse IgG, human IgG, and chicken IgY was demonstrated. The detection limit was 3 ng/mL for all analytes. The sensor had excellent precision (1.9-8.2% interassay CV) and was comparable in performance to commercial single-analyte ELISAs. We anticipate that chip-based sensors, as described herein, will be suitable for the mass production of economical, miniaturized, multianalyte assay devices.
引用
收藏
页码:2507 / 2513
页数:7
相关论文
共 50 条
[31]   Virus detection using array-based technologies. [J].
Perry, K. L. ;
Agindotan, B. ;
Zhang, N. ;
Smart, C. .
PHYTOPATHOLOGY, 2007, 97 (07) :S153-S153
[32]   Analysis of Plasma Cytokine and Chemokine Profiles in Patients with and without Tuberculosis by Liquid Array-Based Multiplexed Immunoassays [J].
Xiong, Wenjing ;
Dong, Haiping ;
Wang, Juanjuan ;
Zou, Xiaoming ;
Wen, Qian ;
Luo, Wei ;
Liu, Sudong ;
He, Jianchun ;
Cai, Shaoxi ;
Ma, Li .
PLOS ONE, 2016, 11 (02)
[33]   Multifunctional flexible sensor array-based damage monitoring for switch rail using passive and active sensing [J].
Hu, Pan ;
Wang, Haitao ;
Tian, Guiyun ;
Liu, Yang ;
Li, Xin ;
Spencer, Billie F. .
SMART MATERIALS AND STRUCTURES, 2020, 29 (09)
[34]   Magnetic Sensor Array-Based AC current Measurement for Multiconductor Cables Using Evolutionary Computation Method [J].
Meng, Lichan ;
Gao, Pengfei ;
Haji, Moosa Moghimi ;
Xu, Wilsun .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (10) :2747-2758
[35]   Immunoassays based on electrochemical detection using microelectrode arrays [J].
Dill, K ;
Montgomery, DD ;
Ghindilis, AL ;
Schwarzkopf, KR ;
Ragsdale, SR ;
Oleinikov, AV .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (04) :736-742
[36]   Ligase-based multiple DNA analysis by using an electrochemical sensor array [J].
Wan, Ying ;
Zhang, Jiong ;
Liu, Gang ;
Pan, Dun ;
Wang, Lihua ;
Song, Shiping ;
Fan, Chunhai .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (05) :1209-1212
[37]   Array-based analog computation [J].
Kramer, AH .
IEEE MICRO, 1996, 16 (05) :20-29
[38]   Peptide array-based interactomics [J].
Hernandez, Daniel Perez ;
Dittmar, Gunnar .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (22) :5561-5566
[39]   Readout of Energy Pulses on Microwave SQUID Multiplexer: A Sensor Array-Based Approach [J].
Kunzler, Jonas A. ;
Lemos, Rodrigo P. ;
Karcher, Nick ;
Sander, Oliver .
IEEE SIGNAL PROCESSING LETTERS, 2021, 28 :41-45
[40]   Multi-FBG sensor array-based impact localization with an energy eigenvector [J].
Jiang Wensong ;
Du Liangya ;
Luo Zai ;
Yang Li ;
Song Hao .
OPTICAL ENGINEERING, 2022, 61 (06)