Changes in visual function under mesopic and photopic conditions after intrastromal corneal ring segment implantation for different stages of keratoconus

被引:11
作者
Carballo, Jesus [1 ]
Cinta Puell, Maria [1 ]
Cuina, Ricardo [2 ]
Maria Vazquez, Jose [1 ]
Benitez-del-Castillo, Jose M. [2 ]
机构
[1] Univ Complutense, Appl Vis Res Grp, Fac Opt & Optometry, Madrid 28037, Spain
[2] Clin San Carlos Hosp, Madrid, Spain
关键词
FEMTOSECOND LASER; INTACS; MANAGEMENT; OUTCOMES; EYES;
D O I
10.1016/j.jcrs.2012.09.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To analyze and compare the changes in visual function under mesopic and photopic conditions in different stages of keratoconus before and after Keraring intrastromal corneal ring segment (ICRS) implantation. SETTING: Clinico San Carlos Hospital and Faculty of Optics and Optometry, Complutense University, Madrid, Spain. DESIGN: Case series. METHODS: Keratoconic eyes were evaluated under mesopic (0.1 to 0.2 candelas [cd]/m(2)) and photopic (85 cd/m(2)) conditions. LogMAR high-contrast corrected distance visual acuity (CDVA) and low-contrast CDVA were assessed using the Bailey-Lovie test and logarithmic contrast sensitivity, using the Pelli-Robson test. RESULTS: The study evaluated 12 eyes with stage I keratoconus, 21 eyes with stage 2, and 14 eyes with stage 3. The mean change in photopic high-contrast CDVA was 0.16 logMAR +/- 0.20 (SD) (P<.00001). Photopic low-contrast CDVA increased by a mean of 0.14 +/- 0.26 logMAR (P=.0005), photopic contrast sensitivity by a mean of 0.09 +/- 0.22 logMAR (P=.005), and mesopic high-contrast CDVA by a mean of 0.10 +/- 0.26 logMAR (P=.03). There were no significant differences between stages. Surgery did not affect the mean changes in mesopic low-contrast CDVA or mesopic contrast sensitivity for any stage. CONCLUSIONS: Implantation of ICRS in keratoconic eyes increased photopic high-contrast CDVA, low-contrast CDVA, and contrast sensitivity. Under low luminance, the mean changes in high-contrast CDVA, low-contrast CDVA, and contrast sensitivity did not worsen after ICRS implantation performed 5.0 mm from the visual axis, despite the rings being partially superimposed on the mydriatic pupil. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. J Cataract Refract Surg 2013; 39:393-402 (C) 2012 ASCRS and ESCRS
引用
收藏
页码:393 / 402
页数:10
相关论文
共 26 条
  • [1] Intrastromal corneal ring segment implantation in 219 keratoconic eyes at different stages
    Alfonso, Jose F.
    Lisa, Carlos
    Fernandez-Vega, Luis
    Madrid-Costa, David
    Montes-Mico, Robert
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (11) : 1705 - 1712
  • [2] One or 2 Intacs segments for the correction of keratoconus
    Alió, JL
    Artola, A
    Hassanein, A
    Haroun, H
    Galal, A
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05) : 943 - 953
  • [3] Alió JL, 2006, J REFRACT SURG, V22, P539
  • [4] Implantation of new intracorneal ring segments after segment explantation for unsuccessful outcomes in eyes with keratoconus
    Alio, Jorge L.
    Pinero, David P.
    Sogutlu, Esin
    Kubaloglu, Anil
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08) : 1303 - 1310
  • [5] FLATTENING OF CENTRAL CORNEAL CURVATURE WITH INTRASTROMAL CORNEAL RINGS OF INCREASING THICKNESS - AN EYE-BANK EYE STUDY
    BURRIS, TE
    BAKER, PC
    AYER, CT
    LOOMAS, BE
    MATHIS, ML
    SILVESTRINI, TA
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 : 182 - 187
  • [6] One-year results of intrastromal corneal ring segment implantation (KeraRing) using femtosecond laser in patients with keratoconus
    Coskunseven, Efekan
    Kymionis, George D.
    Tsiklis, Nikolaos S.
    Atun, Serife
    Arslan, Ebru
    Jankov, Mirko R.
    Pallikaris, Ioannis G.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (05) : 775 - 779
  • [7] THE RELIABILITY OF THE PELLI-ROBSON CONTRAST SENSITIVITY CHART
    ELLIOTT, DB
    SANDERSON, K
    CONKEY, A
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1990, 10 (01) : 21 - 24
  • [8] Microbial Keratitis After Intrastromal Corneal Ring Segment Implantation
    Emilia Mulet, M.
    Perez-Santonja, Juan J.
    Ferrer, Consuelo
    Alio, Jorge L.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 364 - 369
  • [9] Intacs implantation using a femtosecond laser for management of keratoconus: Comparison of 306 cases in different stages
    Ertan, Aylin
    Kamburoglu, Guenhal
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) : 1521 - 1526
  • [10] Intracorneal rings for keratoconus and keratectasia
    Ertan, Aylin
    Colin, Joseph
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) : 1303 - 1314