Influences of Microbubble Diameter and Ultrasonic Parameters on In Vitro Sonothrombolysis Efficacy

被引:33
作者
Borrelli, Michael J. [1 ]
O'Brien, William D., Jr. [2 ]
Hamilton, Eric [1 ]
Oelze, Michael L. [2 ]
Wu, Jonah [1 ]
Bernock, Laura J. [1 ]
Tung, Stephen [3 ]
Rokadia, Husein [3 ]
Culp, William C. [1 ]
机构
[1] Univ Arkansas Med Sci, Dept Radiol, Little Rock, AR 72205 USA
[2] Univ Illinois, Dept Elect & Comp Engn, Bioacoust Res Lab, Urbana, IL USA
[3] Univ Arkansas, Dept Mech Engn, Fayetteville, AR 72701 USA
关键词
TISSUE-PLASMINOGEN ACTIVATOR; FREQUENCY ULTRASOUND; TRANSCRANIAL ULTRASOUND; ENHANCED THROMBOLYSIS; CLOT LYSIS; CAVITATION; ALBUMIN; RECANALIZATION; ANGIOPLASTY; PREDICTION;
D O I
10.1016/j.jvir.2012.08.019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantify the effects of microbubble (MB) size, elasticity, and pulsed ultrasonic parameters on in vitro sonothrombolysis (ultrasound [US]-mediated thrombolysis) efficacy. Materials and Methods: Monodispersive MBs with diameters of 1 mu m or 3 mu m were exposed to pulsed US (1 MHz or 3 MHz) to lyse rabbit blood clots. Sonothrombolysis efficacy (clot mass loss) was measured as functions of MB size and concentration, ultrasonic frequency and intensity, pulse duration (PD), pulse repeat frequency (PRF), and duty factor. Results: Sonothrombolysis at 1 MHz was more effective using 3-mu m MBs and at 3 MHz using 1-mu m MBs. Sonothrombolysis was more effective at 1 MHz when >= 75% of MBs remained intact, especially for 3-mu m MBs; improving sonothrombolysis by increasing PRF from 100 Hz to 400 Hz at 3 MHz was associated with increasing 3-mu m MB survival. However, 60% of 1-mu m MBs were destroyed during maximal sonothrombolysis at 3 MHz, indicating that considerable MB collapse may be required for sonothrombolysis under these conditions. Conclusions: The ability to control MB size and elasticity permits using a wide range of US parameters (eg, frequency, intensity) to produce desired levels of sonothrombolysis. Comparable, maximal sonothrombolysis efficacy was achieved at 20-fold lower intensity with 3-mu m MBs (0.1 W/cm(2)) than with 1-mu m MBs (2.0 W/cm(2)), a potential safety issue for in vivo sonothrombolysis. US parameters that maximized MB survival yielded maximal sonothrombolysis efficacy except with 1-mu m MBs at 3 MHz where most MBs were destroyed.
引用
收藏
页码:1677 / 1684
页数:8
相关论文
共 45 条
  • [1] Ultrasound-enhanced thrombolysis for acute ischemic stroke: Phase I. Findings of the CLOTBUST trial
    Alexandrov, AV
    Demchuk, AM
    Burgin, WS
    Robinson, DJ
    Grotta, JC
    [J]. JOURNAL OF NEUROIMAGING, 2004, 14 (02) : 113 - 117
  • [2] In vivo clot lysis of human thrombus with intravenous abciximab immunobubbles and ultrasound
    Alonso, Angelika
    Dempfle, Carl-Erik
    Della Martina, Alberto
    Stroick, Mark
    Fatar, Marc
    Zohsel, Katrin
    Allemann, Eric
    Hennerici, Michael G.
    Meairs, Stephen
    [J]. THROMBOSIS RESEARCH, 2009, 124 (01) : 70 - 74
  • [3] Ultrasonic contrast agent shell rupture detected by inertial cavitation and rebound signals
    Ammi, AY
    Cleveland, RO
    Mamou, J
    Wang, GI
    Bridal, SL
    O'Brien, WD
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (01) : 126 - 136
  • [4] Production of uniformly sized serum albumin and dextrose microbubbles
    Borrelli, Michael J.
    O'Brien, William D., Jr.
    Bernock, Laura J.
    Williams, Heather R.
    Hamilton, Eric
    Wu, Jonah
    Oelze, Michael L.
    Culp, William C.
    [J]. ULTRASONICS SONOCHEMISTRY, 2012, 19 (01) : 198 - 208
  • [5] Microbubbles Improve Sonothrombolysis In Vitro and Decrease Hemorrhage In Vivo in a Rabbit Stroke Model
    Brown, Aliza T.
    Flores, Rene
    Hamilton, Eric
    Roberson, Paula K.
    Borrelli, Michael J.
    Culp, William C.
    [J]. INVESTIGATIVE RADIOLOGY, 2011, 46 (03) : 202 - 207
  • [7] High rate of recanalization of middle cerebral artery occlusion during 2-MHz transcranial color-coded Doppler continuous monitoring without thrombolytic drug
    Cintas, P
    Le Traon, AP
    Larrue, V
    [J]. STROKE, 2002, 33 (02) : 626 - 628
  • [8] Intracranial clot lysis with intravenous microbubbles and transcranial ultrasound in swine
    Culp, WC
    Porter, TR
    Lowery, J
    Xie, F
    Roberson, PK
    Marky, L
    [J]. STROKE, 2004, 35 (10) : 2407 - 2411
  • [9] Culp WC, 2001, VASC INTERV RADIOL, V11, P351
  • [10] Successful Microbubble Sonothrombolysis Without Tissue-Type Plasminogen Activator in a Rabbit Model of Acute Ischemic Stroke
    Culp, William C.
    Flores, Rene
    Brown, Aliza T.
    Lowery, John D.
    Roberson, Paula K.
    Hennings, Leah J.
    Woods, Sean D.
    Hatton, Jeff H.
    Culp, Benjamin C.
    Skinner, Robert D.
    Borrelli, Michael J.
    [J]. STROKE, 2011, 42 (08) : 2280 - 2285