Analysis of Requirements for Achieving Carbon Neutrality in a Cold Dense City Using GIS

被引:0
作者
Hisato, Osawa [1 ]
Mori, Taro [1 ]
Shinagawa, Kouichi [2 ]
Nakayama, Satoshi [3 ]
Hosobuchi, Hayato [4 ]
Mushtaha, Emad [5 ]
机构
[1] Hokkaido Univ, Grad Sch Engn, Kita Ku, Kita 13,Nishi 8, Sapporo, Hokkaido 0608628, Japan
[2] Nihon Sekkei Inc, Shinjuku Ku, 6-5-1 Nishi Shinjuku, Tokyo 1631329, Japan
[3] Okayama Univ Sci, Fac Engn, Dept Architecture, Kita Ku, 1-1 Ridaicho, Okayama 7000005, Japan
[4] Aichi Inst Technol, Fac Engn, Dept Architecture, 1247 Yachigusa,Yakusa Cho, Toyota 4700392, Japan
[5] Univ Sharjah, Coll Enginerring, Dept Architectural Engn, Sharjah 27272, U Arab Emirates
基金
日本学术振兴会;
关键词
carbon neutrality; GIS; orthographic image; PV; sky view factor; ZEB; OFFICE BUILDINGS; ENERGY;
D O I
10.3390/en15197063
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Photovoltaics (PV) can make a significant contribution to achieving carbon neutrality in buildings. Geographic information systems (GIS) make it easy to model cities and simulate PV with high accuracy. However, the computational burden from 3D urban models remains high. In this study, the complex geometry of a city was represented in 2D images, and we propose a method for performing multiple PV simulations in a short amount of time by using these 2D images. The ratio of electricity generation to primary energy consumption (EG/E) was calculated for 415 office buildings in Sapporo, Japan, and conditions for achieving carbon neutrality in these buildings were explored. For buildings with a small gross floor area, EG/E can be higher than one, and carbon neutrality can be achieved by improving the performance of the exterior walls and windows and by increasing the area of the PV installed. However, to improve EG/E in buildings with a large gross floor area, it is necessary to consider improving the performance of the equipment used and the efficient operation of the HVAC system. The method is useful for considering ways to achieve carbon neutrality in various cities.
引用
收藏
页数:24
相关论文
共 59 条
  • [11] Evaluating the impact of urban morphology on rooftop solar radiation: A new city-scale approach based on Geneva GIS data
    Boccalatte, Alessia
    Thebault, Martin
    Menezo, Christophe
    Ramousse, Julien
    Fossa, Marco
    [J]. ENERGY AND BUILDINGS, 2022, 260
  • [12] Bureau of Environment Tokyo Metropolitan Goverment, FIN EN CONS GREENH G
  • [13] Urban geometry and solar availability on fa ades and ground of real urban forms: using London as a case study
    Chatzipoulka, Christina
    Compagnon, Raphael
    Nikolopoulou, Marialena
    [J]. SOLAR ENERGY, 2016, 138 : 53 - 66
  • [14] Sky view factor analysis of street canyons and its implications for daytime intra-urban air temperature differentials in high-rise, high-density urban areas of Hong Kong: a GIS-based simulation approach
    Chen, Liang
    Ng, Edward
    An, Xipo
    Ren, Chao
    Lee, Max
    Wang, Una
    He, Zhengjun
    [J]. INTERNATIONAL JOURNAL OF CLIMATOLOGY, 2012, 32 (01) : 121 - 136
  • [15] A rapid evaluation method for design strategies of high-rise office buildings achieving nearly zero energy in Guangzhou
    Chen, Sisi
    Zhao, Lihua
    Zheng, Lintao
    Bi, Guanghong
    [J]. JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [16] Cumo F., 2013, Nat. Resour, V4, P134, DOI [10.4236/nr.2013.41A013, DOI 10.4236/NR.2013.41A013]
  • [17] Daiwa Office Investment Corporation, IR LIB IR INF
  • [18] Data Corporation Remote Sensing Technology Center of Japan, AW3D GLOB HIGH RES 3
  • [19] European Union Directive (EU), 2018 844 EUR PARL CO
  • [20] Study on the Influence of Window-wall Ratio on the Energy Consumption of Nearly Zero Energy Buildings
    Feng, Guohui
    Chi, Dandan
    Xu, Xiaolong
    Dou, Baoyue
    Sun, Yixin
    Fu, Yao
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 730 - 737