Tilt and decentration of an intraocular lens implanted in the ciliary sulcus after capsular bag defect during cataract surgery

被引:15
作者
Sauer, Thomas [1 ,2 ]
Mester, Ulrich [1 ]
机构
[1] Knappschafts Hosp, Dept Ophthalmol, Sulzbach, Germany
[2] Univ Eye Hosp Bonn, D-53127 Bonn, Germany
关键词
Pseudophakia; Intraocular lens (IOL); Sulcus fixation; Lens tilt; Spherical intraocular lens; Aberration correcting intraocular lens (AIOL); Higher order aberrations (HOA); Purkinjemeter; SPHERICAL-ABERRATION; OPTICAL ABERRATIONS; CONTRAST SENSITIVITY; OCULAR ABERRATIONS; CRYSTALLINE LENS; IOL IMPLANTATION; IMAGE QUALITY; PHAKIC EYES; IN-VITRO; CORNEA;
D O I
10.1007/s00417-012-2141-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To determine the impact of ciliary sulcus implantation after capsular bag defect on tilt and decentration of foldable intraocular lenses (IOL) measured by a novel device. This prospective noncomparative single-center investigation included patients (N = 10) older than age 60 who underwent cataract surgery with a posterior capsular bag defect and implantation of a threepiece hydrophilic aberration neutral IOL (OphthalmoPro AC 7013) in the ciliary sulcus. All eyes (N = 10) were examined using the OPD-Scan II (Nidek). Spherical aberration (Z4,0), vertical coma (Z3,-1), and horizontal coma (Z3,1) were calculated for a 5.0 mm pupil. Lens tilt and decentration was studied using a new Purkinjemeter. The mean horizontal optic tilt was 7.68A degrees A +/- 5.16 (SD) and the mean vertical optic tilt was 3.01A degrees A +/- 2.44 (SD). Horizontal decentration was 0.4 A +/- 0.33 mm (SD) and vertical decentration was 0.31 A +/- 0.21 mm (SD). Corneal aberrations were partially compensated by IOL- related aberrations. Both tilt and decentration of sulcus-fixated IOLs exceeded the tolerable amounts evaluated for aspheric IOLs in eye model experiments. However, these spheric IOLs showed mitigation rather than accentuation of corneal wavefront aberrations in the rare event of capsular bag defect during cataract surgery.
引用
收藏
页码:89 / 93
页数:5
相关论文
共 27 条
[1]   Contribution of the cornea and internal surfaces to the change of ocular aberrations with age [J].
Artal, P ;
Berrio, E ;
Guirao, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (01) :137-143
[2]   Optical aberrations of intraocular lenses measured in vivo and in vitro [J].
Barbero, S ;
Marcos, S ;
Jiménez-Alfaro, I .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2003, 20 (10) :1841-1851
[3]   Tilt and decentration of spherical and aspheric intraocular lenses: Effect on higher-order aberrations [J].
Baumeister, Martin ;
Buehren, Jens ;
Kohnen, Thomas .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (06) :1006-1012
[4]   Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: A multicenter randomized study [J].
Bellucci, R ;
Scialdone, A ;
Buratto, L ;
Morselli, S ;
Chierego, C ;
Criscuoli, A ;
Moretti, G ;
Piers, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04) :712-717
[5]   Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye [J].
Eppig, Timo ;
Scholz, Katja ;
Loeffler, Andre ;
Messner, Arthur ;
Langenbucher, Achim .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (06) :1091-1100
[6]   Presbyopia and the optical changes in the human crystalline lens with age [J].
Glasser, A ;
Campbell, MCW .
VISION RESEARCH, 1998, 38 (02) :209-229
[7]   Optical aberrations of the human cornea as a function of age [J].
Guirao, A ;
Redondo, M ;
Artal, P .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2000, 17 (10) :1697-1702
[8]  
Guirao A, 2002, ARCH OPHTHALMOL-CHIC, V120, P1143
[9]  
Holladay JT, 2002, J REFRACT SURG, V18, P683
[10]  
Kennis H, 2004, Bull Soc Belge Ophtalmol, P49