An experimental evaluation to determine the required thickness of passive fire protection layer for high strength concrete tunnel segments

被引:14
作者
Bezgin, Niyazi Ozgur [1 ]
机构
[1] Istanbul Univ, Dept Civil Engn, TR-34320 Istanbul, Turkey
关键词
Tunnel boring; Segments; Fire; Spalling; Passive fire protection; High strength concrete; HIGH-PERFORMANCE CONCRETE; HIGH-TEMPERATURE; EXPOSURE; FIBERS;
D O I
10.1016/j.conbuildmat.2015.07.130
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The Eurasia Tunnel is a part of the Bosporus Strait Highway Crossing Project connecting the Anatolian and European shores of Istanbul. This paper evaluates the use of high strength concrete for the segments for the bored part of the tunnel under the effects of design fire conditions. High strength concrete enables the attainment of high early strength levels required for segment handling and increases the segment durability compared to segments designed by ordinary strength concrete. However, in the event of a tunnel fire, the increased concrete strength of the segments increases their likelihood of spalling compared to segments fabricated by ordinary strength concrete. Therefore, determination of the passive fire protection requirements must take into account the strength of the protected concrete. This paper will present and include a discussion of the results of small-scale fire exposure tests conducted to determine the required thickness of passive fire protection layer for the evaluated high strength concrete tunnel segments. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 20 条
  • [1] [Anonymous], FIB B
  • [2] [Anonymous], 2012, ZUS TECHN VERTR RI 5, V5
  • [3] BAZANT ZP, 1997, P INT WORKSH FIR PER, P155
  • [4] An experimental method for assessing the spalling sensitivity of concrete mixture submitted to high temperature
    Debicki, G.
    Haniche, R.
    Delhomme, F.
    [J]. CEMENT & CONCRETE COMPOSITES, 2012, 34 (08) : 958 - 963
  • [5] DLH, 2011, IST STRAIT ROAD TUNN
  • [6] Efnarc, 2006, SPEC GUID TEST PASS
  • [7] Khoury G.A., 2000, Prog. Struct. Eng. Mater., V2, P429, DOI 10.1002/pse.51.URL
  • [8] Effects of the addition of glass fibers, mica and vermiculite on the mechanical properties of a gypsum-based composite at room temperature and during a fire test
    Martias, C.
    Joliff, Y.
    Favotto, C.
    [J]. COMPOSITES PART B-ENGINEERING, 2014, 62 : 37 - 53
  • [9] Rail tunnel risk analysis - A tool to improve rail tunnel design
    Martinelli, Filippo
    Cara, Simone
    Domenichini, Lorenzo
    [J]. TRANSPORTATION RESEARCH RECORD, 2008, 2043 (2043) : 41 - 48
  • [10] Experimental analysis of concrete spalling due to fire exposure
    Mindeguia, Jean-Christophe
    Pimienta, Pierre
    Carre, Helene
    La Borderie, Christian
    [J]. EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2013, 17 (06) : 453 - 466