Diagnostic work-up of pulmonary nodules. Management of pulmonary nodules detected with low-dose CT screening

被引:0
|
作者
Wormanns, D. [1 ]
机构
[1] Evangel Lungenklin Berlin, Lindenberger Weg 27, D-13125 Berlin, Germany
来源
RADIOLOGE | 2016年 / 56卷 / 09期
关键词
Diagnostic algorithms; Low dose CT; Lung neoplasms; Early detection of cancer; Image processing; EARLY LUNG-CANCER; FLEISCHNER-SOCIETY; GROWTH-RATE; STATEMENT; RECOMMENDATIONS;
D O I
10.1007/s00117-016-0150-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Pulmonary nodules are the most frequent pathological finding in low-dose computed tomography (CT) scanning for early detection of lung cancer. Early stages of lung cancer are often manifested as pulmonary nodules; however, the very commonly occurring small nodules are predominantly benign. These benign nodules are responsible for the high percentage of false positive test results in screening studies. Appropriate diagnostic algorithms are necessary to reduce false positive screening results and to improve the specificity of lung cancer screening. Such algorithms are based on some of the basic principles comprehensively described in this article. Firstly, the diameter of nodules allows a differentiation between large (> 8 mm) probably malignant and small (< 8 mm) probably benign nodules. Secondly, some morphological features of pulmonary nodules in CT can prove their benign nature. Thirdly, growth of small nodules is the best noninvasive predictor of malignancy and is utilized as a trigger for further diagnostic work-up. Non-invasive testing using positron emission tomography (PET) and contrast enhancement as well as invasive diagnostic tests (e.g. various procedures for cytological and histological diagnostics) are briefly described in this article. Different nodule morphology using CT (e.g. solid and semisolid nodules) is associated with different biological behavior and different algorithms for followup are required. Currently, no obligatory algorithm is available in German-speaking countries for the management of pulmonary nodules, which reflects the current state of knowledge. The main features of some international and American recommendations are briefly presented in this article from which conclusions for the daily clinical use are derived.
引用
收藏
页码:803 / 809
页数:7
相关论文
共 50 条
  • [1] Benign pulmonary nodules detected by helical low-dose CT screening in comparison with diagnostic HRCT findings
    Li, F
    Sone, S
    Abe, H
    MacMahon, HM
    Armato, SG
    Doi, K
    RADIOLOGY, 2001, 221 : 207 - 207
  • [2] The Value of Flexible Bronchoscopy in the Preoperative Work-Up of Solitary Pulmonary Nodules.
    Schwarz, C.
    Schoenfeld, N.
    Bauer, T. T.
    Loddenkemper, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [3] Deep Learning for Malignancy Risk Estimation of Pulmonary Nodules Detected at Low-Dose Screening CT
    Venkadesh, Kiran Vaidhya
    Setio, Arnaud A. A.
    Schreuder, Anton
    Scholten, Ernst T.
    Chung, Kaman
    Wille, Mathilde M. W.
    Saghir, Zaigham
    van Ginneken, Bram
    Prokop, Mathias
    Jacobs, Colin
    RADIOLOGY, 2021, 300 (02) : 438 - 447
  • [4] THE ROLE OF A CONVENTIONAL BRONCHOSCOPY IN THE WORK-UP OF SUSPICIOUS CT SCREEN DETECTED PULMONARY NODULES
    Van 't Westeinde, Susan C.
    Horeweg, Nanda
    Vernhout, Rene
    Groen, Harry J. M.
    Lammers, Jan-Willem J.
    Weenink, Carla
    Nackaerts, Kristiaan
    Oudkerk, Matthijs
    Mali, Willem
    Thunnissen, Frederik B.
    De Koning, Harry J.
    Van Klaveren, Rob J.
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S1385 - S1386
  • [5] Abklärung von LungenrundherdenManagement durch Früherkennungsuntersuchungen detektierter pulmonaler RundherdeDiagnostic work-up of pulmonary nodulesManagement of pulmonary nodules detected with low‑dose CT screening
    D. Wormanns
    Der Radiologe, 2016, 56 (9): : 803 - 809
  • [6] Automatic detection of pulmonary nodules in low-dose screening thoracic CT examinations
    Fiebich, M
    Wietholt, C
    Renger, BC
    Armato, SG
    Hoffmann, KR
    Wormanns, D
    Diederich, S
    MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 1434 - 1439
  • [7] Radiological diagnosis of small pulmonary nodules detected on low-dose screening computed tomography
    Tsushima, Kenji
    Sone, Shusuke
    Hanaoka, Takaomi
    Kubo, Keishi
    RESPIROLOGY, 2008, 13 (06) : 817 - 824
  • [8] Quantitative radiomic model for predicting malignancy of small solid pulmonary nodules detected by low-dose CT screening
    Mao, Liting
    Chen, Huan
    Liang, Mingzhu
    Li, Kunwei
    Gao, Jiebing
    Qin, Peixin
    Ding, Xianglian
    Li, Xin
    Liu, Xueguo
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (02) : 263 - 272
  • [9] Application effect of low-dose spiral CT on pulmonary nodules and its diagnostic value for benign and malignant nodules
    Zheng, Chengquan
    Wang, Haofeng
    Liu, Qiaozheng
    Han, Dong
    Xin, Yufei
    Lu, Weina
    Yan, Zhenchong
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2023, 15 (01): : 256 - 263
  • [10] Likelihood of malignancy of pulmonary nodules on low-dose helical CT
    Aoyama, M
    Armato, SG
    Li, Q
    Li, F
    Sone, S
    Doi, K
    RADIOLOGY, 2001, 221 : 547 - 547