Simultaneous determination of adenine nucleotides, creatine phosphate and creatine in rat liver by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry

被引:32
|
作者
Jiang, Yang [2 ]
Sun, Chengjun [2 ]
Ding, Xueqin [1 ]
Yuan, Ding [3 ]
Chen, Kefei [3 ]
Gao, Bo [1 ]
Chen, Yi [4 ]
Sun, Aimin [1 ]
机构
[1] Sichuan Univ, Analyt &Testing Ctr, Chengdu 610064, Sichuan, Peoples R China
[2] Sichuan Univ, W China Sch Publ Hlth, Chengdu 610041, Sichuan, Peoples R China
[3] W China Hosp, Regenerat Med Res Ctr, Chengdu 610041, Sichuan, Peoples R China
[4] W China Hosp, Lab Aging & Geriatr Res, Chengdu 610041, Sichuan, Peoples R China
关键词
Adenine nucleotides; Creatine; Creatine phosphate; HPLC-ESI-MS/MS; Rat liver; POROUS GRAPHITIC CARBON; NUCLEOSIDES;
D O I
10.1016/j.jpba.2012.03.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high performance liquid chromatography-electrospray ionization-tandem mass spectrometric method (HPLC-ESI-MS/MS) was developed for simultaneous determination of adenosine 5'-triphosphate (ATP), adenosine 5'-diphosphate (ADP), adenosine 5'-monophosphate (AMP), creatine phosphate (CP), and creatine in rat liver. After extraction with pre-cooled (4 degrees C) methanol/water (1:1, v/v), the analytes were separated on a porous graphitic carbon (Hypercarb) column (2.1 mm x 150 mm, 5 mu m) using a programmed gradient elution with a mobile phase consisting of 2 mmol/L ammonium acetate in water and 2 mmol/L ammonium acetate in acetonitrile (pH = 10.0). The analytes were detected in a way of multiple reaction monitoring (MRM) under negative scan mode by a triple quadrupole mass spectrometer with electrospray ionization (ESI). An external calibration method with linear ranges from 10 to 5000 ng/mL for the five target compounds was used for quantification with a correlation coefficients >= 0.9973. The limits of detection and limits of quantification for all analytes were in ranges from 0.50 to 1.5 ng/mL and 1.6 to 0.5 ng/mL, respectively. The average recoveries spiked in three levels were from 77.2% to 102% and precisions expressed in RSDs were from 0.2% to 4.8%. The established method was successfully applied to determination of ATP, ADP, AMP, CP and creatine in liver tissue. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:258 / 263
页数:6
相关论文
共 50 条
  • [31] Simultaneous determination of guanidinosuccinic acid and guanidinoacetic acid in urine using high performance liquid chromatography/tandem mass spectrometry
    Saigusa, Daisuke
    Suzuki, Naoto
    Takahashi, Mai
    Shiba, Kanako
    Tanaka, Satoshi
    Abe, Takaaki
    Hishinuma, Takanori
    Tomioka, Yoshihisa
    ANALYTICA CHIMICA ACTA, 2010, 677 (02) : 169 - 175
  • [32] Analysis of urinary nucleosides as potential tumor markers in human colorectal cancer by high performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Hsu, Wei-Yi
    Chen, William Tzu-Liang
    Lin, Wei-De
    Tsai, Fuu-Jen
    Tsai, Yuhsin
    Lin, Ching-Tsung
    Lo, Wan-Yu
    Jeng, Long-Bin
    Lai, Chien-Chen
    CLINICA CHIMICA ACTA, 2009, 402 (1-2) : 31 - 37
  • [33] Analysis of urinary nucleosides as potential tumor markers in human breast cancer by high performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Hsu, Wei-Yi
    Lin, Wei-De
    Tsai, Yuhsin
    Lin, Chiung-Tsung
    Wang, Hwei-Chung
    Jeng, Long-Bin
    Lee, Ching-Chih
    Lin, Yu-Chiang
    Lai, Chien-Chen
    Tsai, Fuu-Jen
    CLINICA CHIMICA ACTA, 2011, 412 (19-20) : 1861 - 1866
  • [34] Simultaneous quantitative determination of microcystin-LR and its glutathione metabolites in rat liver by liquid chromatography-tandem mass spectrometry
    Guo, Xiaochun
    Xie, Ping
    Chen, Jun
    Tuo, Xun
    Deng, Xuwei
    Li, Shangchun
    Yu, Dezhao
    Zeng, Cheng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 963 : 54 - 61
  • [35] Suppression effects of carbonate on the interaction between stainless steel and phosphate groups of phosphate compounds in high-performance liquid chromatography and electrospray ionization mass spectrometry
    Asakawa, Yoshiki
    Tokida, Noriaki
    Ozawa, Chinami
    Ishiba, Masahiko
    Tagaya, Osamu
    Asakawa, Naoki
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1198 : 80 - 86
  • [36] Comparison of release and penetration of tacrolimus ointment reference and trial formulation after dermal application to pigs by liquid chromatography-electrospray ionization tandem mass spectrometry
    Ma, Lifang
    Wang, Xiting
    Fu, Zhengyan
    Sun, Aimin
    Gao, Bo
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (09) : 1117 - 1122
  • [37] Simultaneous determination nucleosides in marine organisms using ultrasound-assisted extraction followed by hydrophilic interaction liquid chromatography-electrospray ionization time-of-flight mass spectrometry
    Zhao, Hengqiang
    Chen, Junhui
    Shi, Qian
    Li, Xin
    Zhou, Wenhui
    Zhang, Daolai
    Zheng, Li
    Cao, Wei
    Wang, Xiaoru
    Lee, Frank Sen-Chun
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (19) : 2594 - 2601
  • [38] Simultaneous determination of twenty heterocyclic amines in cooking oil using dispersive solid phase extraction (QuEChERS) and high performance liquid chromatography-electrospray-tandem mass spectrometry
    Chang, Chia-Chi
    Zhang, Dequan
    Wang, Zhenyu
    Chen, Bing-Huei
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1585 : 82 - 91
  • [39] Measurement of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA and human urine by high performance liquid chromatography-electrospray tandem mass spectrometry
    Weimann, A
    Belling, D
    Poulsen, HE
    FREE RADICAL BIOLOGY AND MEDICINE, 2001, 30 (07) : 757 - 764
  • [40] Analysis of Chemical Constituents of Traditional Chinese Medicinal Formula Huang-Qi-Chi-Feng-Tang by High Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometry
    Xu, Jingjing
    Zhu, Yingchao
    Lin, Li
    Jiang, Yanyan
    Liu, Bin
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (08) : 4367 - 4371