Acute Effects of a Heat-Not-Burn Tobacco Product on Pulmonary Function

被引:22
作者
Pataka, Athanasia [1 ]
Kotoulas, Seraphim [1 ]
Chatzopoulos, Evangelos [1 ]
Grigoriou, Ioanna [1 ]
Sapalidis, Konstantinos [2 ]
Kosmidis, Christoforos [2 ]
Vagionas, Anastasios [3 ]
Perdikouri, Eleni-Isidora [4 ]
Drevelegas, Konstantinos [5 ]
Zarogoulidis, Paul [2 ]
Argyropoulou, Paraskevi [1 ]
机构
[1] Aristotle Univ Thessaloniki, G Papanikolaou Hosp, Med Sch, Resp Failure Unit, Thessaloniki 54124, Greece
[2] Aristotle Univ Thessaloniki, Ahepa Univ Hosp, Med Sch, Dept Surg 3, Thessaloniki 54124, Greece
[3] Gen Hosp Kavala, Oncol Deaprtment, Kavala 65500, Greece
[4] Gen Hosp Volos, Oncol Dept, Volos 38222, Greece
[5] Euromed Private Diagnost Lab, Radiol Dept, Thessaloniki 54124, Greece
来源
MEDICINA-LITHUANIA | 2020年 / 56卷 / 06期
关键词
heated tobacco; IQOS; respiratory function; resistance; exhaled CO; acute effects; CIGARETTE-SMOKING; CARBON-MONOXIDE; SMALL AIRWAYS; SMOKERS; REDUCTION; SYSTEM;
D O I
10.3390/medicina56060292
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: During the last decade, conventional tobacco smoking is experiencing a decline and new smoking products have been introduced. IQOS ("I-Quit-Ordinary-Smoking") is a type of "heat-not-burn" (HNB) tobacco product. The impact of IQOS on respiratory health is currently not defined. The objectives of this study were to evaluate the acute effects of IQOS on pulmonary function in non-smokers and current smokers.Materials and Methods:Fifty male healthy non-smokers and current smokers with no known co-morbidity underwent an exhaled CO measurement, oximetry (SaO2%), pulmonary function tests (flows, volumes and diffusion capacity), and a measurement of respiratory resistances with an impulse oscillometry system (IOS) before and immediately after IQOS use.Results:In the whole group of 50 participants, SaO2%, forced expiratory flow at 25% and 50% of vital capacity (FEF 25%, FEF 50%, respectively), peak expiratory flow (PEF), and diffusion lung capacity for carbon monoxide/VA (KCO) decreased significantly after IQOS use, whereas exhaled CO and airway resistance (R5 Hz, R10 Hz, r15 Hz, R20 Hz, R25 Hz, R35 Hz) increased. When the groups of smokers and non-smokers were compared, in both groups (all males, 25 smokers and 25 non-smokers), exhaled CO increased and SaO2% decreased after IQOS use (p< 0.001). In the group of non-smokers, PEF (pre 8.22 +/- 2.06 vs. post 7.5 +/- 2.16,p= 0.001) and FEF 25% (pre 7.6 +/- 1.89 vs. 7.14 +/- 2.06,p= 0.009) decreased significantly; respiratory resistances R20 Hz (pre 0.34 +/- 0.1 vs. post 0.36 +/- 0.09,p= 0.09) and R25 Hz (pre 0.36 +/- 0.1 vs. post 0.38 +/- 0.09,p= 0.08) increased almost significantly. In smokers, PEF (pre 7.69 +/- 2.26 vs. post 7.12 +/- 2.03,p= 0.007) and expiratory reserve volume (ERV) (pre 1.57 +/- 0.76 vs. post1.23 +/- 0.48,p= 0.03) decreased and R35 Hz (pre 0.36 +/- 0.11 vs. post 0.39 +/- 0.11,p= 0.047) increased. The differences in the changes after the use of IQOS did not differ between groups.Conclusions:IQOS had an impact on exhaled CO, SaO2%, and airways function immediately after use. Even though these changes were rather small to be considered of major clinical importance, they should raise concerns regarding the long-term safety of this product. Further research is needed for the short- and long-term effects of IQOS, especially in patients with respiratory disease.
引用
收藏
页码:1 / 11
页数:10
相关论文
共 29 条
[21]   Heat-not-burn tobacco products: a systematic literature review [J].
Simonavicius, Erikas ;
McNeill, Ann ;
Shahab, Lion ;
Brose, Leonie S. .
TOBACCO CONTROL, 2019, 28 (05) :582-594
[22]   Evaluation of the Tobacco Heating System 2.2. Part 1: Description of the system and the scientific assessment program [J].
Smith, Maurice R. ;
Clark, Bruce ;
Ludicke, Frank ;
Schaller, Jean-Pierre ;
Vanscheeuwijck, Patrick ;
Hoeng, Julia ;
Peitsch, Manuel C. .
REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2016, 81 :S17-S26
[23]   IQOS exposure impairs human airway cell homeostasis: direct comparison with traditional cigarette and e-cigarette [J].
Sohal, Sukhwinder Singh ;
Eapen, Mathew Suji ;
Naidu, Vegi G. M. ;
Sharma, Pawan .
ERJ OPEN RESEARCH, 2019, 5 (01)
[24]   Clearing the smoke: the science base for tobacco harm reduction - executive summary (Reprinted from National Academy Press, 2001) [J].
Stratton, K ;
Shetty, P ;
Wallace, R ;
Bondurant, S .
TOBACCO CONTROL, 2001, 10 (02) :189-195
[25]   Exposure to Electronic Cigarettes Impairs Pulmonary Anti-Bacterial and Anti-Viral Defenses in a Mouse Model [J].
Sussan, Thomas E. ;
Gajghate, Sachin ;
Thimmulappa, Rajesh K. ;
Ma, Jinfang ;
Kim, Jung-Hyun ;
Sudini, Kuladeep ;
Consolini, Nicola ;
Cormier, Stephania A. ;
Lomnicki, Slawo ;
Hasan, Farhana ;
Pekosz, Andrew ;
Biswal, Shyam .
PLOS ONE, 2015, 10 (02)
[26]   Acute effects of cigarette smoking on pulmonary function [J].
Unverdorben, M. ;
Mostert, A. ;
Munjal, S. ;
van der Bijl, A. ;
Potgieter, L. ;
Venter, C. ;
Liang, Q. ;
Meyer, B. ;
Roethig, H. -J. .
REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2010, 57 (2-3) :241-246
[27]   Short-term Pulmonary Effects of Using an Electronic Cigarette Impact on Respiratory Flow Resistance, Impedance, and Exhaled Nitric Oxide [J].
Vardavas, Constantine I. ;
Anagnostopoulos, Nektarios ;
Kougias, Marios ;
Evangelopoulou, Vassiliki ;
Connolly, Gregory N. ;
Behrakis, Panagiotis K. .
CHEST, 2012, 141 (06) :1400-1406
[28]   Noninvasive assessment of airway alterations in smokers - The small airways revisited [J].
Verbanck, S ;
Schuermans, D ;
Meysman, M ;
Paiva, M ;
Vincken, W .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 170 (04) :414-419
[29]   CARBON-MONOXIDE IN BREATH IN RELATION TO SMOKING AND CARBOXYHEMOGLOBIN LEVELS [J].
WALD, NJ ;
IDLE, M ;
BOREHAM, J ;
BAILEY, A .
THORAX, 1981, 36 (05) :366-369