Three-dimensional ultrashort echo magnetic resonance imaging of orthodontic appliances in the natural dentition

被引:11
作者
Cox, Ryan J. [1 ]
Kau, Chung How [1 ]
Rasche, Volker [2 ]
机构
[1] Univ Alabama Birmingham, Dept Orthodont, Birmingham, AL 35294 USA
[2] Univ Ulm, Dept Internal Med 2, D-7900 Ulm, Germany
关键词
TEMPOROMANDIBULAR-JOINT; TEETH; MRI; NMR;
D O I
10.1016/j.ajodo.2012.03.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to determine whether ultrashort echo time magnetic resonance imaging technology could be used to image teeth with orthodontic appliances in place. Methods: High-resolution 3-T ultrashort echo time magnetic resonance imaging was performed on 60 extracted premolars with fixed ceramic orthodontic appliances (Clarity, 3M Unitek, Monrovia, Calif; Radiance, American Orthodontics, Sheboygan, Wis; and Ice, Ormco, Glendora, Calif). The teeth were collected from the orthodontic clinic at the University of Alabama at Birmingham, and the institutional review board of the University of Alabama at Birmingham approved the study. Linear measurements of tooth morphology and orthodontic bracket dimensions were acquired with calipers and compared with virtual digital magnetic resonance imaging. The spin echo and high spatial resolution multi-slice turbo spin echo were only used for visual comparison with the ultrashort echo time slices. Both the caliper and the ultrashort echo time magnetic resonance imaging measurements were highly reliable and accurate. Comparisons between the 2 methods showed no statistically significant differences in any bracket or tooth dimensions, with a P value of >0.05. In general, the differences in the values ranged from -0.01 to 0.06 mm. A visual evaluation scale was used to assess the quality of the ultrashort echo time magnetic resonance images when assessing the delineation of dental hard tissues. Results: The visual evaluation scale of the images showed that enamel, dentin, pulp, and ceramic orthodontic appliances could be subjectively delineated at a high level with the ultrashort echo time magnetic resonance imaging. Conclusions: The following conclusions can be drawn from this prospective study. Ceramic orthodontic appliances, without metal components, cause no dental image distortions and are readily visible on the ultrashort echo time magnetic resonance imaging scans. The measurements comparing linear tooth measurements with virtual digital magnetic resonance images demonstrated that magnetic resonance imaging has statistically and clinically significant accuracy on external tooth and bracket measurements. Visual evaluation of the images showed that enamel, dentin, pulp, and ceramic orthodontic appliances could be subjectively delineated at a high level with ultrashort echo time magnetic resonance imaging. Metallic slots in ceramic appliances cause severe image distortions. These distortions are localized and should not affect surrounding tissues in full-volume magnetic resonance imaging. (Am J Orthod Dentofacial Orthop 2012;142:552-61)
引用
收藏
页码:552 / 561
页数:10
相关论文
共 50 条
  • [41] Qualitative and Quantitative Assessment of Isotropic Ankle Magnetic Resonance Imaging: Three-Dimensional Isotropic Intermediate-Weighted Turbo Spin Echo versus Three-Dimensional. Isotropic Fast Field Echo Sequences
    Kim, Hyun Su
    Yoon, Young Cheol
    Kwon, Jong Won
    Choe, Bong-Keun
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (04) : 443 - 449
  • [42] Magnetic Resonance Imaging of Ankle Syndesmotic Ligament Injuries: Comparison of Three-dimensional Isotropic Intermediate-weighted Fast Spin Echo with Conventional Two-dimensional Imaging
    Park, J. W.
    Lee, S. J.
    Choo, H. J.
    Gwak, H. C.
    Park, D. H.
    Kim, M. W.
    HONG KONG JOURNAL OF RADIOLOGY, 2020, 23 (03): : 391 - 397
  • [43] Three-dimensional ultrashort echo time (3D UTE) magnetic resonance imaging (MRI) of the normal and degenerative disco-vertebral complex at 4.7 T: a feasibility study with longitudinal evaluation
    Dallaudiere, Benjamin
    Ribot, Emeline J.
    Trotier, Aurelien J.
    Loubrie, Stephane
    Dallet, Laurence
    Thibaudeau, Olivier
    Miraux, Sylvain
    Hauger, Olivier
    EUROPEAN SPINE JOURNAL, 2021, 30 (05) : 1144 - 1154
  • [44] Three-Dimensional In vivo Magnetic Resonance Imaging (MRI) of Mouse Facial Nerve Regeneration
    Wanner, Renate
    Abaei, Alireza
    Rasche, Volker
    Knoell, Bernd
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [45] Three-dimensional morphological magnetic resonance imaging in infants and children with congenital heart disease
    Fenchel, Michael
    Greil, Gerald F.
    Martirosian, Petros
    Kramer, Ulrich
    Schick, Fritz
    Claussen, Claus D.
    Sieverding, Ludger
    Miller, Stephan
    PEDIATRIC RADIOLOGY, 2006, 36 (12) : 1265 - 1272
  • [46] A pilot study comparing three-dimensional models of tumor histopathology and magnetic resonance imaging
    Koivuholma, Anne
    Sistonen, Heli J.
    Aro, Katri
    Makitie, Antti
    Hagstrom, Jaana
    Atula, Timo
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [47] Fetal magnetic resonance imaging and three-dimensional ultrasound in clinical practice: General aspects
    Sepulveda, Waldo
    Wong, Amy E.
    Sepulveda, Francisco
    Martinez-Ten, Pilar
    Ximenes, Renato
    BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2012, 26 (05) : 575 - 591
  • [48] Three-dimensional morphological magnetic resonance imaging in infants and children with congenital heart disease
    Michael Fenchel
    Gerald F. Greil
    Petros Martirosian
    Ulrich Kramer
    Fritz Schick
    Claus D. Claussen
    Ludger Sieverding
    Stephan Miller
    Pediatric Radiology, 2006, 36 : 1265 - 1272
  • [49] Quantitative three-dimensional cardiovascular magnetic resonance myocardial perfusion imaging in systole and diastole
    Motwani, Manish
    Kidambi, Ananth
    Sourbron, Steven
    Fairbairn, Timothy A.
    Uddin, Akhlaque
    Kozerke, Sebastian
    Greenwood, John P.
    Plein, Sven
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [50] Characterisation of the guinea pig model of osteoarthritis by in vivo three-dimensional magnetic resonance imaging
    Tessier, JJ
    Bowyer, J
    Brownrigg, NJ
    Peers, IS
    Westwood, FR
    Waterton, JC
    Maciewicz, RA
    OSTEOARTHRITIS AND CARTILAGE, 2003, 11 (12) : 845 - 853