Three-dimensional ultrashort echo magnetic resonance imaging of orthodontic appliances in the natural dentition

被引:11
作者
Cox, Ryan J. [1 ]
Kau, Chung How [1 ]
Rasche, Volker [2 ]
机构
[1] Univ Alabama Birmingham, Dept Orthodont, Birmingham, AL 35294 USA
[2] Univ Ulm, Dept Internal Med 2, D-7900 Ulm, Germany
关键词
TEMPOROMANDIBULAR-JOINT; TEETH; MRI; NMR;
D O I
10.1016/j.ajodo.2012.03.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to determine whether ultrashort echo time magnetic resonance imaging technology could be used to image teeth with orthodontic appliances in place. Methods: High-resolution 3-T ultrashort echo time magnetic resonance imaging was performed on 60 extracted premolars with fixed ceramic orthodontic appliances (Clarity, 3M Unitek, Monrovia, Calif; Radiance, American Orthodontics, Sheboygan, Wis; and Ice, Ormco, Glendora, Calif). The teeth were collected from the orthodontic clinic at the University of Alabama at Birmingham, and the institutional review board of the University of Alabama at Birmingham approved the study. Linear measurements of tooth morphology and orthodontic bracket dimensions were acquired with calipers and compared with virtual digital magnetic resonance imaging. The spin echo and high spatial resolution multi-slice turbo spin echo were only used for visual comparison with the ultrashort echo time slices. Both the caliper and the ultrashort echo time magnetic resonance imaging measurements were highly reliable and accurate. Comparisons between the 2 methods showed no statistically significant differences in any bracket or tooth dimensions, with a P value of >0.05. In general, the differences in the values ranged from -0.01 to 0.06 mm. A visual evaluation scale was used to assess the quality of the ultrashort echo time magnetic resonance images when assessing the delineation of dental hard tissues. Results: The visual evaluation scale of the images showed that enamel, dentin, pulp, and ceramic orthodontic appliances could be subjectively delineated at a high level with the ultrashort echo time magnetic resonance imaging. Conclusions: The following conclusions can be drawn from this prospective study. Ceramic orthodontic appliances, without metal components, cause no dental image distortions and are readily visible on the ultrashort echo time magnetic resonance imaging scans. The measurements comparing linear tooth measurements with virtual digital magnetic resonance images demonstrated that magnetic resonance imaging has statistically and clinically significant accuracy on external tooth and bracket measurements. Visual evaluation of the images showed that enamel, dentin, pulp, and ceramic orthodontic appliances could be subjectively delineated at a high level with ultrashort echo time magnetic resonance imaging. Metallic slots in ceramic appliances cause severe image distortions. These distortions are localized and should not affect surrounding tissues in full-volume magnetic resonance imaging. (Am J Orthod Dentofacial Orthop 2012;142:552-61)
引用
收藏
页码:552 / 561
页数:10
相关论文
共 50 条
  • [31] Magnetic resonance ultrashort echo time spin-echo imaging of the deepest layers of articular cartilage
    Gao Song
    Du Jiang
    Wang Fei
    Bao ShangLian
    SCIENCE CHINA-LIFE SCIENCES, 2013, 56 (07) : 672 - 674
  • [32] Three-dimensional Magnetic Resonance Imaging of Physeal Injury: Reliability and Clinical Utility
    Lurie, Brett
    Koff, Matthew F.
    Shah, Parina
    Feldmann, Eric James
    Amacker, Nadja
    Downey-Zayas, Timothy
    Green, Daniel
    Potter, Hollis G.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2014, 34 (03) : 239 - 245
  • [33] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Zhang, Jing
    Chen, Lang
    Wang, Qiu-Xia
    Liu, Rong
    Zhu, Wen-Zhen
    Luo, Xin
    Peng, Li
    Xiong, Wei
    NEURORADIOLOGY, 2015, 57 (04) : 357 - 365
  • [34] Three-dimensional digital atlas construction of Chinese brains by magnetic resonance imaging
    Lu, Jianhua
    Chen, Zhiwei
    Chen, Zhong
    Yan, Zhiping
    Yao, Yi
    Luo, Wanneng
    Su, Sulian
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2006 - +
  • [35] Reconstruction of Magnetic Resonance Imaging by Three-Dimensional Dual-Dictionary Learning
    Song, Ying
    Zhu, Zhen
    Lu, Yang
    Liu, Qiegen
    Zhao, Jun
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 1285 - 1298
  • [36] Ultrashort Echo Time Quantitative Magnetic Resonance Imaging of the Cruciate Ligaments in Normal Beagles
    Socha, Dennis E.
    Pownder, Sarah L.
    Kayano, Mitsunori
    Koff, Matthew F.
    Hayashi, Kei
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2024, 37 (03) : 145 - 150
  • [37] Three-dimensional quantification of magnetic resonance imaging artifacts associated with shape factors
    Kawabata, Iku
    Imai, Haruki
    Kanno, Zuisei
    Tetsumura, Akemi
    Tsutsumi, Yusuke
    Doi, Hisashi
    Ashida, Maki
    Kurabayashi, Tohru
    Hanawa, Takao
    Yamamoto, Toru
    Ono, Takashi
    DENTAL MATERIALS JOURNAL, 2019, 38 (04) : 638 - 645
  • [38] Diagnostic Accuracy of Three-dimensional Turbo Field Echo Magnetic Resonance Imaging Sequence in Pediatric Tracheobronchial Anomalies with Congenital Heart Disease
    Hou, QiaoRu
    Gao, Wei
    Zhong, YuMin
    Sun, AiMin
    Wang, Qian
    Hu, LiWei
    Wang, JingLei
    SCIENTIFIC REPORTS, 2018, 8
  • [39] Impact of orthodontic appliances on the quality of craniofacial anatomical magnetic resonance imaging and real-time speech imaging
    Wylezinska, Marzena
    Pinkstone, Marie
    Hay, Norman
    Scott, Andrew D.
    Birch, Malcolm J.
    Miquel, Marc E.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (06) : 610 - 617
  • [40] Denoising of volumetric magnetic resonance imaging using multichannel three-dimensional convolutional neural network with applications on fast spin echo acquisitions
    Zhao, Shutian
    Xiao, Fan
    Griffith, James F.
    Li, Ruokun
    Chen, Weitian
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (09) : 6517 - 6530