Three-dimensional ultrashort echo magnetic resonance imaging of orthodontic appliances in the natural dentition

被引:11
|
作者
Cox, Ryan J. [1 ]
Kau, Chung How [1 ]
Rasche, Volker [2 ]
机构
[1] Univ Alabama Birmingham, Dept Orthodont, Birmingham, AL 35294 USA
[2] Univ Ulm, Dept Internal Med 2, D-7900 Ulm, Germany
关键词
TEMPOROMANDIBULAR-JOINT; TEETH; MRI; NMR;
D O I
10.1016/j.ajodo.2012.03.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to determine whether ultrashort echo time magnetic resonance imaging technology could be used to image teeth with orthodontic appliances in place. Methods: High-resolution 3-T ultrashort echo time magnetic resonance imaging was performed on 60 extracted premolars with fixed ceramic orthodontic appliances (Clarity, 3M Unitek, Monrovia, Calif; Radiance, American Orthodontics, Sheboygan, Wis; and Ice, Ormco, Glendora, Calif). The teeth were collected from the orthodontic clinic at the University of Alabama at Birmingham, and the institutional review board of the University of Alabama at Birmingham approved the study. Linear measurements of tooth morphology and orthodontic bracket dimensions were acquired with calipers and compared with virtual digital magnetic resonance imaging. The spin echo and high spatial resolution multi-slice turbo spin echo were only used for visual comparison with the ultrashort echo time slices. Both the caliper and the ultrashort echo time magnetic resonance imaging measurements were highly reliable and accurate. Comparisons between the 2 methods showed no statistically significant differences in any bracket or tooth dimensions, with a P value of >0.05. In general, the differences in the values ranged from -0.01 to 0.06 mm. A visual evaluation scale was used to assess the quality of the ultrashort echo time magnetic resonance images when assessing the delineation of dental hard tissues. Results: The visual evaluation scale of the images showed that enamel, dentin, pulp, and ceramic orthodontic appliances could be subjectively delineated at a high level with the ultrashort echo time magnetic resonance imaging. Conclusions: The following conclusions can be drawn from this prospective study. Ceramic orthodontic appliances, without metal components, cause no dental image distortions and are readily visible on the ultrashort echo time magnetic resonance imaging scans. The measurements comparing linear tooth measurements with virtual digital magnetic resonance images demonstrated that magnetic resonance imaging has statistically and clinically significant accuracy on external tooth and bracket measurements. Visual evaluation of the images showed that enamel, dentin, pulp, and ceramic orthodontic appliances could be subjectively delineated at a high level with ultrashort echo time magnetic resonance imaging. Metallic slots in ceramic appliances cause severe image distortions. These distortions are localized and should not affect surrounding tissues in full-volume magnetic resonance imaging. (Am J Orthod Dentofacial Orthop 2012;142:552-61)
引用
收藏
页码:552 / 561
页数:10
相关论文
共 50 条
  • [21] Three-Dimensional Reconstruction of the Craniofacial Skeleton With Gradient Echo Magnetic Resonance Imaging ("Black Bone''): What Is Currently Possible?
    Eley, Karen A.
    Watt-Smith, Stephen R.
    Golding, Stephen J.
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (02) : 463 - 467
  • [22] Rapid acquisition of magnetic resonance imaging of the shoulder using three-dimensional fast spin echo sequence with compressed sensing
    Lee, Seung Hyun
    Lee, Young Han
    Song, Ho-Taek
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2017, 42 : 152 - 157
  • [23] Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
    Klimes, Filip
    Voskrebenzev, Andreas
    Wacker, Frank
    Vogel-Claussen, Jens
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (208):
  • [24] Three-dimensional localization of impacted teeth using magnetic resonance imaging
    Tymofiyeva, O.
    Rottner, K.
    Jakob, P. M.
    Richter, E. -J.
    Proff, P.
    CLINICAL ORAL INVESTIGATIONS, 2010, 14 (02) : 169 - 176
  • [25] Magnetic resonance imaging for in vivo assessment of three-dimensional patellar tracking
    Fellows, RA
    Hill, NA
    Gill, HS
    MacIntyre, NJ
    Harrison, MM
    Ellis, RE
    Wilson, DR
    JOURNAL OF BIOMECHANICS, 2005, 38 (08) : 1643 - 1652
  • [26] Artifacts Caused by Orthodontic Appliances on Magnetic Resonance Imaging: Awareness and Knowledge Level of Maxillofacial Radiologists and Orthodontists
    Pamukcu, Umut
    Tortop, Tuba
    Ozuturk, Oezge
    Kemaloglu, Sibel Acik
    Peker, Ilkay
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2024, 14 (01): : 77 - 86
  • [27] An Update in Qualitative Imaging of Bone Using Ultrashort Echo Time Magnetic Resonance
    Jerban, Saeed
    Chang, Douglas G.
    Ma, Yajun
    Jang, Hyungseok
    Chang, Eric Y.
    Du, Jiang
    FRONTIERS IN ENDOCRINOLOGY, 2020, 11
  • [28] Quantitative Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of Bone: An Update
    Ma, Ya-Jun
    Jerban, Saeed
    Jang, Hyungseok
    Chang, Douglas
    Chang, Eric Y.
    Du, Jiang
    FRONTIERS IN ENDOCRINOLOGY, 2020, 11
  • [29] Three-dimensional visualization of teeth by magnetic resonance imaging during speech
    Ventura, Sandra R.
    Freitas, Diamantino R.
    Ramos, Isabel M.
    Tavares, Joao Manuel R. S.
    BIODENTAL ENGINEERING II, 2014, : 13 - 17
  • [30] Magnetic permeability as a predictor of the artefact size caused by orthodontic appliances at 1.5 T magnetic resonance imaging
    Blankenstein, Felix H.
    Asbach, Patrick
    Beuer, Florian
    Glienke, Johannes
    Mayer, Stefan
    Zachriat, Christine
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (01) : 281 - 289