Three-dimensional ultrashort echo magnetic resonance imaging of orthodontic appliances in the natural dentition

被引:11
|
作者
Cox, Ryan J. [1 ]
Kau, Chung How [1 ]
Rasche, Volker [2 ]
机构
[1] Univ Alabama Birmingham, Dept Orthodont, Birmingham, AL 35294 USA
[2] Univ Ulm, Dept Internal Med 2, D-7900 Ulm, Germany
关键词
TEMPOROMANDIBULAR-JOINT; TEETH; MRI; NMR;
D O I
10.1016/j.ajodo.2012.03.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to determine whether ultrashort echo time magnetic resonance imaging technology could be used to image teeth with orthodontic appliances in place. Methods: High-resolution 3-T ultrashort echo time magnetic resonance imaging was performed on 60 extracted premolars with fixed ceramic orthodontic appliances (Clarity, 3M Unitek, Monrovia, Calif; Radiance, American Orthodontics, Sheboygan, Wis; and Ice, Ormco, Glendora, Calif). The teeth were collected from the orthodontic clinic at the University of Alabama at Birmingham, and the institutional review board of the University of Alabama at Birmingham approved the study. Linear measurements of tooth morphology and orthodontic bracket dimensions were acquired with calipers and compared with virtual digital magnetic resonance imaging. The spin echo and high spatial resolution multi-slice turbo spin echo were only used for visual comparison with the ultrashort echo time slices. Both the caliper and the ultrashort echo time magnetic resonance imaging measurements were highly reliable and accurate. Comparisons between the 2 methods showed no statistically significant differences in any bracket or tooth dimensions, with a P value of >0.05. In general, the differences in the values ranged from -0.01 to 0.06 mm. A visual evaluation scale was used to assess the quality of the ultrashort echo time magnetic resonance images when assessing the delineation of dental hard tissues. Results: The visual evaluation scale of the images showed that enamel, dentin, pulp, and ceramic orthodontic appliances could be subjectively delineated at a high level with the ultrashort echo time magnetic resonance imaging. Conclusions: The following conclusions can be drawn from this prospective study. Ceramic orthodontic appliances, without metal components, cause no dental image distortions and are readily visible on the ultrashort echo time magnetic resonance imaging scans. The measurements comparing linear tooth measurements with virtual digital magnetic resonance images demonstrated that magnetic resonance imaging has statistically and clinically significant accuracy on external tooth and bracket measurements. Visual evaluation of the images showed that enamel, dentin, pulp, and ceramic orthodontic appliances could be subjectively delineated at a high level with ultrashort echo time magnetic resonance imaging. Metallic slots in ceramic appliances cause severe image distortions. These distortions are localized and should not affect surrounding tissues in full-volume magnetic resonance imaging. (Am J Orthod Dentofacial Orthop 2012;142:552-61)
引用
收藏
页码:552 / 561
页数:10
相关论文
共 50 条
  • [1] Three-dimensional ultrashort echo time magnetic resonance imaging in pediatric patients with pneumonia: a comparative study
    Sun, Yan
    Chen, Yujie
    Li, Xuesheng
    Liao, Yi
    Chen, Xijian
    Song, Yu
    Liang, Xinyue
    Dai, Yongming
    Chen, Dapeng
    Ning, Gang
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [2] Assessment of the sacroiliac joint in patients with axial spondyloarthritis via three-dimensional ultrashort echo time magnetic resonance imaging
    Ren, Cui
    Zhu, Qiao
    Li, Qing
    Sommer, Stefan
    Zhang, Xianchang
    Yuan, Huishu
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (06) : 4141 - 4154
  • [3] Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients
    Zeimpekis, Konstantinos G.
    Geiger, Julia
    Wiesinger, Florian
    Delso, Gaspar
    Kellenberger, Christian J.
    PEDIATRIC RADIOLOGY, 2021, 51 (01) : 57 - 65
  • [4] Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging
    Namiranian, Behnam
    Jerban, Saeed
    Ma, Yajun
    Dorthe, Erik W.
    Masoud-Afsahi, Amir
    Wong, Jonathan
    Wei, Zhao
    Chen, Yanjun
    D'Lima, Darryl
    Chang, Eric Y.
    Du, Jiang
    JOURNAL OF BIOMECHANICS, 2020, 113
  • [5] Three-dimensional ultrashort echo time cones (3D UTE-Cones) magnetic resonance imaging of entheses and tendons
    Chen, Bimin
    Zhao, Yinghua
    Cheng, Xin
    Ma, Yajun
    Chang, Eric Y.
    Kavanaugh, Arthur
    Liu, Sirun
    Du, Jiang
    MAGNETIC RESONANCE IMAGING, 2018, 49 : 4 - 9
  • [6] Three-dimensional magnetic resonance imaging for groundwater
    Legchenko, A.
    Descloitres, M.
    Vincent, C.
    Guyard, H.
    Garambois, S.
    Chalikakis, K.
    Ezersky, M.
    NEW JOURNAL OF PHYSICS, 2011, 13
  • [7] Three-dimensional ultrashort echo time magnetic resonance imaging in assessment of idiopathic pulmonary fibrosis, in comparison with high-resolution computed tomography
    Yang, Xiaoyan
    Liu, Min
    Duan, Jianghui
    Sun, Haishuang
    An, Jing
    Benkert, Thomas
    Dai, Huaping
    Wang, Chen
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (08) : 4176 - +
  • [8] Spatially resolved polymer mobilization revisited - Three-dimensional, UltraShort Echo Time (3D UTE) magnetic resonance imaging of sodium alginate matrix tablets
    Baran, Ewelina
    Birczynski, Artur
    Dorozynski, Przemyslaw
    Kulinowski, Piotr
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2023, 649 : 626 - 634
  • [9] Short T2 contrast with three-dimensional ultrashort echo time imaging
    Du, Jiang
    Bydder, Mark
    Takahashi, Atsushi M.
    Carl, Michael
    Chung, Christine B.
    Bydder, Graeme M.
    MAGNETIC RESONANCE IMAGING, 2011, 29 (04) : 470 - 482
  • [10] Three-dimensional ultrashort echo time imaging with tricomponent analysis for human cortical bone
    Lu, Xing
    Jerban, Saeed
    Wan, Lidi
    Ma, Yajun
    Jang, Hyungseok
    Le, Nicole
    Yang, Wenhui
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) : 348 - 355