This paper discusses the steam leakage of a 300MW steam turbine unit and its effect on the turbine's economy and efficiency by calculation in details. Then it introduces the measures used to deal with this problem at site.
引用
收藏
页码:862 / 866
页数:5
相关论文
共 50 条
  • [41] The location governor hydraulic system's design and application of 300MW class pumped storage unit
    He, Linbo
    Cai, Jun
    Zhou, Pan
    Qin, Weichao
    Chen, Xiaoyong
    Xie, Jiarong
    Xu, Dong
    Wang, Wei
    Zhang, Lei
    Cai, Xiaofeng
    Shao, Yixiang
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 804 - +
  • [42] The development of FGD DCS simulation system on a 300MW thermal power unit based on the virtual technology
    Huang Xianming
    Zhong Qin
    ENERGY EDUCATION SCIENCE AND TECHNOLOGY PART A-ENERGY SCIENCE AND RESEARCH, 2011, 28 (01): : 27 - 36
  • [43] Energy loss detection system of a 300 MW steam turbine set based on C/S structure
    Hu, Nian-Su
    Guo, Qiang
    Shen, Li
    Fan, Tian-Jing
    Dongli Gongcheng/Power Engineering, 2002, 22 (04):
  • [44] An all-condition simulation model of the steam turbine system for a 600 MW generation unit
    Zhang, Yanping
    Wang, Jizhou
    Yang, Shujin
    Gao, Wei
    JOURNAL OF THE ENERGY INSTITUTE, 2018, 91 (02) : 279 - 288
  • [45] EXPERIMENTAL DYNAMIC CHARACTERISTICS OF TPP-110 BOILER IN A 300MW UNIT
    VINOGRAD.AA
    LISICHAN.ID
    YUDINSON, AP
    BOGDANOV, VK
    MALYUTIN, IB
    PERELMAN, AS
    THERMAL ENGINEERING, 1968, 15 (01) : 1 - &
  • [46] 300MW level evaporative cooling turbine generator stator temperature field analysis
    Guo Jianhong
    Yuan Jian-hua
    Fu Deping
    Luan Ru
    Xiong Bin
    2009 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2009, : 279 - +
  • [47] The in situ repair of the bottom cover of a 300MW pump turbine at Dinorwig power station
    Moss, WO
    Jones, G
    HYDRO POWER DEVELOPMENTS - CURRENT PROJECTS, REHABILITATION, AND POWER RECOVERY, 1997, 97 (04): : 63 - 71
  • [48] Thermodynamical performance analysis of Shanghai optimized and licensed 300 MW steam turbine
    Wang, Xingping
    Zhang, Xingzheng
    Dongli Gongcheng/Power Engineering, 18 (03): : 9 - 16
  • [49] Calculation and research on undercapacity of imported type 300 MW steam turbine units
    Kan, Weimin
    Zhang, Junjie
    Zhu, Hongbo
    Wuhan Shuili Dianli Daxue Xuebao/Journal of Wuhan University of Hydraulic and Electric Engineering, 1999, 32 (06): : 70 - 73
  • [50] Noise level statistics and fuzzy classification of 125MW and 300MW turbine-generator sets
    Zeng, Hong
    Du, Jin-gen
    Wu, Mei-rong
    Dongli Gongcheng/Power Engineering, 1988, 8 (05): : 37 - 43