Design of a Surface Plasmon Resonance CO Sensor

被引:5
作者
Perez-Ocon, Francisco [1 ]
Pozo, Antonio Manuel [1 ]
Cortina, Jorge [2 ]
Rabaza, Ovidio [2 ]
机构
[1] Univ Granada, Opt Dept, Granada 18071, Spain
[2] Indra Syst SA, Madrid 28108, Spain
关键词
CO sensor; surface plasmon resonance sensor; nanosensor; CARBON-MONOXIDE; THIN-FILM; OZONE; CU;
D O I
10.3390/s22093299
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbon monoxide (CO) is a highly toxic gas, which can cause death if it is inhaled in small quantities for a long time or in large quantities for a short time. Since this gas can be lethal, it is essential to detect it from minute to large concentrations. Our study consists of the design of a superficial plasmonic resonance (SPR) CO sensor of tiny dimensions which is capable of giving an immediate response at different concentrations. It is designed to work at different heights above sea level since the refractive index of this gas depends on a mixture with air and the air pressure. Due to its low weight and tiny dimensions, it is ideal for space travel or on airplanes. The results show a high resolution and sensitivity (similar to 10(-)(5 )RIU of resolution and a sensitivity of 13.51-81.26 RIU-1).
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Influence of Chalcogenide Glass on Surface Plasmon Resonance based Sensor Design in Near Infrared Region using Admittance Loci Method
    Brahmachari, Kaushik
    Ray, Mina
    2012 5TH INTERNATIONAL CONFERENCE ON COMPUTERS AND DEVICES FOR COMMUNICATION (CODEC), 2012,
  • [32] Experimental study of the copper-coated hollow fiber surface plasmon resonance sensor
    Luo, Gengyu
    Zhang, Xian
    Zhu, Xiao-Song
    Shi, Yi-Wei
    OPTICS COMMUNICATIONS, 2022, 520
  • [33] Detection of Leptospirosis Bacteria in Rodent Urine by Surface Plasmon Resonance Sensor Using Graphene
    Raikwar, Surjeet
    Prajapati, Y. K.
    Srivastava, D. K.
    Maurya, J. B.
    Saini, J. P.
    PHOTONIC SENSORS, 2021, 11 (03) : 305 - 313
  • [34] A surface plasmon resonance sensor based on a multi-core photonic crystal fiber
    Zhang P.-P.
    Yao J.-Q.
    Cui H.-X.
    Lu Y.
    Optoelectronics Letters, 2013, 9 (5) : 342 - 345
  • [35] Surface Plasmon Resonance Sensor Based on Polymer Photonic Crystal Fibers with Metal Nanolayers
    Lu, Ying
    Hao, Cong-Jing
    Wu, Bao-Qun
    Musideke, Mayilamu
    Duan, Liang-Cheng
    Wen, Wu-Qi
    Yao, Jian-Quan
    SENSORS, 2013, 13 (01) : 956 - 965
  • [36] A Kretschmann-type absorption-based surface plasmon resonance waveguide sensor
    Shibayama, Jun
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2008, 50 (10) : 2497 - 2500
  • [37] Ultrasensitively sensing acephate using molecular imprinting techniques on a surface plasmon resonance sensor
    Wei, Chuanping
    Zhou, Huiqing
    Zhou, Jie
    TALANTA, 2011, 83 (05) : 1422 - 1427
  • [38] Coupled mode surface plasmon resonance sensor: in situ detection of humidity with starch biofilm
    Yadav, Gulab Chand
    Sharma, Gaurav
    Singh, Vivek
    Kumar, Manindra
    Srivastava, Neelam
    Kumar, Sushil
    Gupta, Vinay
    OPTICAL AND QUANTUM ELECTRONICS, 2018, 50 (01)
  • [39] Surface plasmon resonance sensor coated with poriferous MIPs for microcystin-LR detection
    He, Hao
    Zhang, Tao
    Yao, Jia
    Li, Chuan-Yu
    Zhou, Lian-Qun
    Wang, Yi
    Li, Ming-Yu
    Li, Hai-Wen
    Dong, Wen-Fei
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2015, 23 (03): : 723 - 728
  • [40] The rapid measurement of ABO blood type by using surface-plasmon resonance sensor
    Nanameki, K
    Ushijima, H
    Akase, S
    Matsumoto, T
    Kamata, S
    BUNSEKI KAGAKU, 1999, 48 (07) : 669 - 672