Gemini Interfaces in Aqueous Lubrication with Hydrogels

被引:94
作者
Dunn, Alison C. [1 ]
Sawyer, W. Gregory [1 ]
Angelini, Thomas E. [1 ,2 ,3 ]
机构
[1] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL 32611 USA
[2] Univ Florida, J Crayton Pruitt Family Dept Biomed Engn, Gainesville, FL 32611 USA
[3] Univ Florida, Inst Cell Engn & Regenerat Med, Gainesville, FL 32611 USA
关键词
Hydrogel lubricity; Aqueous lubrication; Microtribology; INTERSTITIAL FLUID PRESSURIZATION; ARTICULAR-CARTILAGE; CONTACT-LENSES; MODEL;
D O I
10.1007/s11249-014-0308-1
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The sliding interfaces found in the body-within the eyes, the digestive system, and the articulating joints, for example-are soft and permeable yet extremely robust, possessing low friction. The common elements among these systems are hydrophilic biopolymer networks that provide physical surfaces, elasticity, and fluid permeability. Stiff, impermeable probes are traditionally used to assess the frictional properties of most surfaces, including soft, permeable materials. However, both sides of physiological articulating interfaces are soft and hydrated. Measuring the friction response on just one-half of the cornea-eyelid interface or the cartilage-cartilage interface using a stiff, impermeable probe may not reproduce physiological lubrication. Here, we present lubricity measurements of the interface between two soft, hydrated, and permeable hydrogels. We explore the distinctions between the self-mated "Gemini" hydrogel interface and hydrogels sliding against hard impermeable countersurfaces. A rigid impermeable probe sliding against a soft permeable hydrogel exhibits strong frictional dependence on sliding speed, and a hydrogel probe sliding against flat glass shows a strong friction dependence on time in contact. The twin Gemini interface shows very low friction mu < 0.06, with little dependence on sliding speed or time in contact. This consistently low-friction Gemini interface emulates the physiological condition of two like permeable surfaces in contact, providing excellent lubricity.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 26 条
  • [1] Rolling resistance of articular cartilage due to interstitial fluid flow
    Ateshian, GA
    Wang, H
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (05) : 419 - 424
  • [2] The role of interstitial fluid pressurization in articular cartilage lubrication
    Ateshian, Gerard A.
    [J]. JOURNAL OF BIOMECHANICS, 2009, 42 (09) : 1163 - 1176
  • [3] Fluid load support during localized indentation of cartilage with a spherical probe
    Bonnevie, E. D.
    Baro, V. J.
    Wang, L.
    Burris, D. L.
    [J]. JOURNAL OF BIOMECHANICS, 2012, 45 (06) : 1036 - 1041
  • [4] A review of lubrication conditions for wear simulation in artificial hip replacements
    Brown, SS
    Clarke, IC
    [J]. TRIBOLOGY TRANSACTIONS, 2006, 49 (01) : 72 - 78
  • [5] De Gennes P.-G, 1979, Scaling concepts in polymer physics
  • [6] Hydration lubrication: exploring a new paradigm
    Gaisinskaya, Anastasya
    Ma, Liran
    Silbert, Gilad
    Sorkin, Raya
    Tairy, Odeya
    Goldberg, Ronit
    Kampf, Nir
    Klein, Jacob
    [J]. FARADAY DISCUSSIONS, 2012, 156 : 217 - 233
  • [7] Deletion of active ADAMTS5 prevents cartilage degradation in a murine model of osteoarthritis
    Glasson, SS
    Askew, R
    Sheppard, B
    Carito, B
    Blanchet, T
    Ma, HL
    Flannery, CR
    Peluso, D
    Kanki, K
    Yang, ZY
    Majumdar, MK
    Morris, EA
    [J]. NATURE, 2005, 434 (7033) : 644 - 648
  • [8] Lubrication mode analysis of articular cartilage using Stribeck surfaces
    Gleghorn, Jason P.
    Bonassar, Lawrence J.
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (09) : 1910 - 1918
  • [9] OBSERVATIONS ON THE STRUCTURE OF A POLYACRYLAMIDE-GEL FROM ELECTRON-MICROGRAPHS
    HSU, TP
    COHEN, C
    [J]. POLYMER, 1984, 25 (10) : 1419 - 1423
  • [10] Jen AC, 1996, BIOTECHNOL BIOENG, V50, P357, DOI 10.1002/(SICI)1097-0290(19960520)50:4<357::AID-BIT2>3.0.CO