Techno-economic analysis of a solar-powered humidification-dehumidification desalination system under fogging effect

被引:22
|
作者
Alrbai, Mohammad [1 ]
Hayajneh, Hassan [2 ]
Arakza, Faris [1 ]
Enizat, Jamil [1 ]
Al-Dahidi, Sameer [3 ]
Al-Ghussain, Loiy [4 ]
Hassan, Muhammed A. [5 ]
机构
[1] Univ Jordan, Dept Mech Engn, Sch Engn, Amman 11942, Jordan
[2] Purdue Univ Northwest, Mechatron Engn Technol, Dept Engn Technol, Coll Technol, 2200 169th St, Hammond, IN 46323 USA
[3] German Jordanian Univ, Mech & Maintenance Engn Dept, Amman 11180, Jordan
[4] Univ Kentucky, Mech Engn Dept, Lexington, KY 40506 USA
[5] Cairo Univ, Fac Engn, Mech Power Engn Dept, Giza 12613, Egypt
关键词
Water desalination; Humidification-dehumidification; Fogging nozzles; Solar energy; Gained output ratio; Economic analysis; PERFORMANCE; UNIT;
D O I
10.1016/j.seta.2022.102752
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Different techniques are utilized to overcome the problem of freshwater shortage around the world. Humidification-dehumidification technology is among the promising methods, especially when powered by cost-effective solar energy sources or when used in remote desert areas with abundant solar resources. In this study, a solar energy-powered humidification-dehumidification system is assembled and tested. Two solar energy systems are supplying the humidification-dehumidification system with heat and electricity, namely an evacuated tube solar collector and an array of photovoltaic panels, respectively. The studied system utilizes three fogging nozzles, each with a 10-mu m diameter, that allow efficient energy conversion. Also, the system was tested under the influence of a single nozzle with a larger diameter for comparison purposes. The fogging technique reduced the power consumption while boosting the total system productivity. The system was able to achieve a maximum gained output ratio of 4.4 at saline water and air temperatures of 80 and 53.44 degrees C, respectively. The rate of freshwater production ranged between 1.7 and 3.85 L/h. At the highest tested saline water to air ratio, the system with three 10-mu m nozzles enhanced the gained output ratio by 23.68 and 67.33 %, compared to the single nozzle configuration with 20 and 30-mu m diameter, respectively. An economic evaluation showed a best-averaged price of 0.0543 USD/L of freshwater.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Performance analysis of a heat pump driven humidification-dehumidification desalination system
    Dehghani, Saeed
    Date, Abhijit
    Akbarzadeh, Aliakbar
    DESALINATION, 2018, 445 : 95 - 104
  • [42] STUDYING THE POTENTIAL OF DEPLOYING INTEGRATED HUMIDIFICATION-DEHUMIDIFICATION DESALINATION SYSTEM WITH SOLAR THERMAL SYSTEM
    Abedi, Mahyar
    Saha, Parnab
    Tan, Xu
    Klausner, James F.
    Benard, Andre
    8TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, 2023, : 629 - 640
  • [43] Thermal analysis of humidification-dehumidification desalination system based on evacuated tube solar air heater
    Tiwari, Abhishek
    Kumar, Amit
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (12) : 6585 - 6602
  • [44] Techno-economic feasibility of a solar-powered reverse osmosis desalination system integrated with lithium battery energy storage
    Meratizaman, Mousa
    Godarzi, Ali Abbasi
    DESALINATION AND WATER TREATMENT, 2019, 167 : 57 - 74
  • [45] Analysis of a solar desalination unit with humidification-dehumidification cycle using DoE method
    Farsad, S.
    Behzadmehr, A.
    DESALINATION, 2011, 278 (1-3) : 70 - 76
  • [46] The potential of integrating solar-powered membrane distillation with a humidification-dehumidification system to recover potable water from textile wastewater
    Shaikh, Javed Sikandar
    Aswalekar, Uday
    Ismail, Saleel
    Akhade, Aniket
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2024, 205
  • [47] Numerical study and experimental validation of a solar powered humidification-dehumidification desalination system with integrated air and water collectors in the humidifier
    Saidi, Sirine
    Ben Radhia, Rym
    Nafiri, Naima
    Benhamou, Brahim
    Ben Jabrallah, Sadok
    RENEWABLE ENERGY, 2023, 206 : 466 - 480
  • [48] Techno-Economic and Environmental Impact Analysis of a 50 MW Solar-Powered Rankine Cycle System
    Akroot, Abdulrazzak
    Al Shammre, Abdullah Sultan
    PROCESSES, 2024, 12 (06)
  • [49] Energy, exergy, economic, exergo and enviro-economic analysis of solar powered humidification dehumidification desalination system: An experimental investigation
    Tiwari, Abhishek
    Kumar, Amit
    APPLIED THERMAL ENGINEERING, 2024, 246
  • [50] Cost Optimization of a Solar Humidification-Dehumidification Desalination System Augmented by Thermal Energy Storage
    Abd El-Aziz, Khalid M.
    Kim, Jihun
    Hamza, Karim
    El Morsi, Mohamed
    Nassef, Ashraf O.
    Metwalli, Sayed M.
    Saitou, Kazuhiro
    INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2015, VOL 2A, 2016,