Use of acoustic emission and ultrasonic techniques for monitoring crack initiation/growth during ratcheting studies on 304LN stainless steel straight pipe

被引:36
作者
Mukhopadhyay, C. K. [1 ]
Jayakumar, T. [1 ]
Haneef, T. K. [1 ]
Kumar, S. Suresh [2 ]
Rao, B. P. C. [1 ]
Goyal, Sumit [3 ]
Gupta, Suneel K. [3 ]
Bhasin, Vivek [3 ]
Vishnuvardhan, S. [4 ]
Raghava, G. [4 ]
Gandhi, P. [4 ]
机构
[1] Indira Gandhi Ctr Atom Res, Non Destruct Evaluat Div, Kalpakkam 603102, Tamil Nadu, India
[2] BHAVINI, Kalpakkam 603102, Tamil Nadu, India
[3] Bhabha Atom Res Ctr, Reactor Safety Div, Bombay 400085, Maharashtra, India
[4] CSIR, Struct Engn Res Ctr, Madras 600113, Tamil Nadu, India
关键词
Acoustic emission; Ultrasonic; Ratcheting; 304LN stainless steel; Through-thickness crack; AISI TYPE 304-STAINLESS-STEEL; SA333; GR.6; STEEL; TENSILE DEFORMATION; NOTCHED SPECIMENS; FAILURE; FATIGUE; STRESS; ALLOY;
D O I
10.1016/j.ijpvp.2014.01.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes the use of acoustic emission (AE) and ultrasonic techniques for monitoring crack initiation/growth during ratcheting studies on a straight pipe made of 304LN austenitic stainless steel under reversed four point bending. Generation of higher AE activity and AE events with higher peak amplitudes accompanied by AE cluster formation in a localized region between 826 and 845 cycles revealed the initiation of crack during the ratcheting test. Ultrasonic examination by using multiple skip technique conducted periodically at regular intervals of 25 cycles confirmed the formation of the crack only after 1000 cycles. Final rupture of the pipe occurred by through-thickness cracks after 1203 and 1225 cycles at two locations. In the range of cycles where the cracks grew, AE increased with the accumulated cycles, indicating good correlation between crack growth and AE. Acoustic emission was correlated with ballooning. While the ballooning rate decreases with cycles, count rate for different sensors increase. This has been attributed to the superposition of the generation of AE due to crack growth which increases continuously to that generated by circumferential change in strain. The superior sensitivity and reliability of acoustic emission for early detection of fatigue cracks during ratcheting test in pipe specimen is demonstrated. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:27 / 36
页数:10
相关论文
共 34 条
[1]  
Acoustic Emission Testing, 2005, NONDESTRUCTIVE TESTI, V6
[2]   Acoustic emission source location on large plate-like structures using a local triangular sensor array [J].
Aljets, Dirk ;
Chong, Alex ;
Wilcox, Steve ;
Holford, Karen .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2012, 30 :91-102
[3]  
[Anonymous], 2009, A312A312M09 ASTM
[4]  
[Anonymous], E213309 ASTM
[5]  
[Anonymous], P 27 JAP C MAT RES
[6]  
[Anonymous], NONDESTRUCTIVE TESTI, V7
[7]  
[Anonymous], E58710 ASTM
[8]   Designing a magnetoacoustic emission measurement configuration for measurement of creep damage in power plant boiler tubes [J].
Augustyniak, B ;
Chmielewski, M ;
Piotrowski, L ;
Sablik, MJ .
JOURNAL OF APPLIED PHYSICS, 2002, 91 (10) :8897-8899
[9]   THE USE OF ACOUSTIC-EMISSION TO EVALUATE CRITICAL-VALUES OF K AND J IN 7075-T651 ALUMINUM-ALLOY [J].
BLANCHETTE, Y ;
DICKSON, JI ;
BASSIM, MN .
ENGINEERING FRACTURE MECHANICS, 1984, 20 (02) :359-&
[10]   RELATIONSHIP BETWEEN ACOUSTIC-EMISSION AND CTOD TESTING FOR A STRUCTURAL-STEEL [J].
CAMERINI, CS ;
REBELLO, JMA ;
SOARES, SD .
NDT & E INTERNATIONAL, 1992, 25 (03) :127-133