Microvolt T-wave alternans for risk stratification of cardiac events in ischemic cardiomyopathy: A meta-analysis

被引:9
|
作者
Chen, Zhen [1 ,2 ]
Shi, Yue [1 ]
Hou, Xiaofeng [1 ]
Xu, Shudong [2 ]
Zou, Jiangang [1 ]
机构
[1] Nanjing Med Univ, Affiliated Hosp 1, Div Cardiol, Nanjing 210009, Jiangsu, Peoples R China
[2] Taixing Hosp, Div Cardiol, Taixing, Jiangsu, Peoples R China
关键词
Microvolt T-wave alternans; Ischemic cardiomyopathy; Cardiac mortality; Arrhythmia; Meta-analysis; VENTRICULAR TACHYARRHYTHMIC EVENTS; ARRHYTHMIA VULNERABILITY; DEATH; EJECTION; THERAPY; BENEFIT;
D O I
10.1016/j.ijcard.2012.05.050
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The ability of microvolt T-wave alternans (MTWA) for risk stratification of cardiac events in patients with ischemic cardiomyopathy (ICM) has not been well established. Methods: The authors systematically reviewed current literature and carried out a meta-analysis to determine the ability of MTWA to predict the outcome severity after ICM. Major endpoints include composite endpoint of cardiac mortality and severe arrhythmic events in primary prevention of patients with ICM, as well as all-cause mortality (cardiac death, and/or non-cardiac death). Results: Seven trials were included by using MTWA for risk stratification of cardiac events in 3385 patients with ICM. All patients were distributed into two groups according to the results of MTWA tests: non-negative group included positive and indeterminate, and negative group. Compared with the negative group, non-negative group showed increased rates of cardiac mortality or severe arrhythmic events (RR=1.65, 95% CrI=1.32, 2.071), sudden cardiac death (SCD) (RR=2.04 95% CrI=1.11, 3.75), and all-cause mortality (RR=2.11, 95% CrI=1.60, 2.79). The funnel plot revealed that there might be bias within current publications. The fail-safe number of composite endpoint and all-cause mortality was 14.42 and 18.93, respectively (when P=0.01). The fail-safe number of SCD was 1.07 (when P=0.05), which may be caused by the small case number of included studies and some patients with ICD included. Conclusions: The non-negative group of MTWA had a nearly double risk of severe outcomes compared with the negative group. Therefore, MTWA represents a potential useful tool for judging the severity of ICM. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2061 / 2065
页数:5
相关论文
共 50 条
  • [1] Microvolt T-wave alternans in ischemic cardiomyopathy
    Madias, John E.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 162 (02) : 135 - 136
  • [2] Microvolt T-wave alternans: an effective approach to risk stratification in ischemic cardiomyopathy? Commentary
    Bigger, J. Thomas
    Bloomfield, Daniel M.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2007, 4 (06): : 300 - 301
  • [3] Predictive Value of Microvolt T-Wave Alternans for Cardiac Death or Ventricular Tachyarrhythmic Events in Ischemic and Nonischemic Cardiomyopathy Patients: A Meta-Analysis
    Calo, Leonardo
    De Santo, Tiziana
    Nuccio, Francesca
    Sciarra, Luigi
    De Luca, Lucia
    Stefano, Lorenza Mangoni di S.
    Piroli, Enrico
    Zuccaro, Lorenzo
    Rebecchi, Marco
    de Ruvo, Ermenegildo
    Lioy, Ernesto
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2011, 16 (04) : 388 - 402
  • [4] The Usefulness of Microvolt T-Wave Alternans in the Risk Stratification of Patients with Hypertrophic Cardiomyopathy
    Fuchs, Therese
    Torjman, Amram
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2009, 11 (10): : 606 - 610
  • [5] Ability of microvolt T-wave alternans to modify risk assessment of ventricular tachyarrhythmic events: A meta-analysis
    Gupta, Anurag
    Hoang, Donald D.
    Karliner, Leah
    Tice, Jeffrey A.
    Heidenreich, Paul
    Wang, Paul J.
    Turakhia, Mintu P.
    AMERICAN HEART JOURNAL, 2012, 163 (03) : 354 - 364
  • [6] Can microvolt T-wave alternans predict mortality in patients with ischemic cardiomyopathy?
    Hohnloser, Stefan H.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2006, 3 (09): : 470 - 471
  • [7] Microvolt T-wave alternans amplifies spatial dispersion of repolarization in human subjects with ischemic cardiomyopathy
    Pasala, Tilak
    Dettmer, Mary
    Leo, Peter J.
    Laurita, Kenneth R.
    Kaufman, Elizabeth S.
    JOURNAL OF ELECTROCARDIOLOGY, 2016, 49 (05) : 733 - 739
  • [8] Baroreflex sensitivity but not microvolt T-wave alternans can predict major adverse cardiac events in ischemic heart failure
    Kaufmann, Damian K.
    Raczak, Grzegorz
    Szwoch, Malgorzata
    Wabich, Elzbieta
    Swiatczak, Michal
    Danilowicz-Szymanowicz, Ludmila
    CARDIOLOGY JOURNAL, 2022, 29 (06) : 1004 - 1012
  • [9] Is microvolt T-wave alternans the answer to risk stratification in heart failure?
    Myles, Rachel C.
    Jackson, Colette E.
    Tsorlalis, Ioannis
    Petrie, Mark C.
    McMurray, John J. V.
    Cobbe, Stuart M.
    CIRCULATION, 2007, 116 (25) : 2984 - 2991
  • [10] Do Beta-Blockers Impact Microvolt T-Wave Alternans Testing in Patients at Risk for Ventricular Arrhythmias? A Meta-Analysis
    Chan, Paul S.
    Gold, Michael R.
    Nallamothu, Brahmajee K.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (09) : 1009 - 1014