Design and Quantitative Analysis of Fluorescent Immunoassay Detection System

被引:0
|
作者
Liu, Hongli [1 ]
Song, Jian [1 ]
Shao, Lei [1 ]
Li, Ji [1 ]
Chen, Xiaoqi [1 ]
机构
[1] Tianjin Univ Technol, Tianjin Key Lab Control Theory & Applicat Complic, Tianjin 300384, Peoples R China
关键词
Quantitative detection; Signal collecting; Fluorescence analysis; Wavelet denoising;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Quantitative detection of fluorescence immunoassay is widely used in clinical detection. For this reason, through a reasonable design of optoelectronic circuits real-time detection system, designing a set of fully functional fluorescence immunochromatographic quantitative detection system is necessary, which integrates a large number of peripheral modules, including fluorescence signal collecting, motion control, fluorescence signal processing data, quantitative curve fining and testing results. After the improved threshold wavelet demising through experiments, the system performance is very good, quantitative results are accurate. So, the system of fluorescence analysis has a vital significance.
引用
收藏
页码:3513 / 3518
页数:6
相关论文
共 50 条
  • [11] A Cellulose Paper-Based Fluorescent Lateral Flow Immunoassay for the Quantitative Detection of Cardiac Troponin I
    Natarajan, Satheesh
    Jayaraj, Joseph
    Prazeres, Duarte Miguel F.
    BIOSENSORS-BASEL, 2021, 11 (02):
  • [12] Lateral flow fluorescent immunoassay based on isothermal amplification for rapid quantitative detection of Salmonella spp.
    Zhuang, Linlin
    Gong, Jiansen
    Ji, Yongxin
    Tian, Peilong
    Kong, Fei
    Bai, Huiyuan
    Gu, Ning
    Zhang, Yu
    ANALYST, 2020, 145 (06) : 2367 - 2377
  • [13] A Cellulose Paper-Based Fluorescent Lateral Flow Immunoassay for the Quantitative Detection of Cardiac Troponin I
    Natarajan S.
    Jayaraj J.
    Prazeres D.M.F.
    Biosensors, 2021, 11 (02):
  • [14] Evaluation of an automated enzyme-linked fluorescent immunoassay system for the detection of salmonellae in foods
    Keith, M
    JOURNAL OF FOOD PROTECTION, 1997, 60 (06) : 682 - 685
  • [15] QUANTITATIVE FLUORESCENT IMMUNOASSAY FOR OUTER MEMBRANES OF BACTEROIDES-FRAGILIS
    TRINCHER, RC
    RISSING, JP
    NEWMAN, CL
    CLINICAL RESEARCH, 1979, 27 (05): : A749 - A749
  • [16] Development of a fluorescent latex immunoassay for detection of a spectinomycin antibiotic
    Medina, MB
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (11) : 3231 - 3236
  • [17] AN AUTOMATED FLUORESCENT ENZYME-IMMUNOASSAY FOR THE DETECTION OF HBSAG
    CLEMENS, JM
    SCHMIDT, WW
    WICKLUND, KW
    CLINICAL CHEMISTRY, 1988, 34 (06) : 1154 - 1154
  • [18] Detection of Histoplasma antigen by a quantitative enzyme immunoassay
    Connolly, Patricia A.
    Durkin, Michelle M.
    LeMonte, Ann M.
    Hackett, Emily J.
    Wheat, L. Joseph
    CLINICAL AND VACCINE IMMUNOLOGY, 2007, 14 (12) : 1587 - 1591
  • [19] Quantitative SERRS immunoassay for the detection of human PSA
    Stevenson, Ross
    Ingram, Andrew
    Leung, Hing
    McMillan, Donald C.
    Graham, Duncan
    ANALYST, 2009, 134 (05) : 842 - 844
  • [20] QUANTITATIVE DETECTION OF AUTOANTIBODIES TO 2 NUCLEAR ANTIGENS (RIBONUCLEOPROTEIN AND SM) BY A SOLID-PHASE FLUORESCENT IMMUNOASSAY (FIAX)
    EWEL, C
    DRAYER, A
    AGRIS, P
    ROSEBROCK, J
    OBEIRNE, A
    FEDERATION PROCEEDINGS, 1987, 46 (04) : 1370 - 1370