Simulation of the observability of atomic defects by atomic force microscopy in contact and non-contact modes

被引:5
|
作者
Sokolov, IY [1 ]
Henderson, GS
机构
[1] Clarkson Univ, Dept Phys, Potsdam, NY 13699 USA
[2] Univ Toronto, Dept Geol, Toronto, ON M5S 3B1, Canada
关键词
atomic force microscopy; surface defects; computer simulations; atom-solid interactions;
D O I
10.1016/S0039-6028(01)01763-0
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Atomic force microscopy (AFM) scans of a crystal surface containing an atomic defect were simulated in both contact and non-contact regimes. When scanning in contact mode near a defect, the tip-sample force interaction experiences bifurcation of the lines of constant force. When the load force is small, the bifurcation causes the tip to be 'pushed" out of the defect. However, if scan force is higher than some critical value (dependent upon the composition of the tip and sample) the AFM tip becomes "trapped" in the vicinity of defect. The trapped tip remains at the level of the vacancy and consequently crashes into the sample, as the scan continues. This results in either the tip apex being destroyed, or disruption of the crystal lattice around the defect. Both effects result in the "disappearance" of the defect from the scan images. The trap is intrinsic and cannot be avoided. For the case of non-contact mode, the tip position is driven by the scan force gradient rather than the force. Simulations show that for this case the trap does not exist and atomic defects will not be destroyed. This explains why atomic defects are generally not observed when using contact mode AFM, but are observed in non-contact AFM. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
  • [1] Contact and non-contact mode imaging by atomic force microscopy
    Morita, S
    Fujisawa, S
    Kishi, E
    Ohta, M
    Ueyama, H
    Sugawara, Y
    THIN SOLID FILMS, 1996, 273 (1-2) : 138 - 142
  • [2] Energy Dissipation Mechanism of Non-Contact Atomic Force Microscopy for Movable Objects
    Harada, Masanori
    Tsukada, Masaru
    E-JOURNAL OF SURFACE SCIENCE AND NANOTECHNOLOGY, 2008, 6 : 1 - 6
  • [3] Local oxidation of titanium films by non-contact atomic force microscopy
    Fang, Te-Hua
    Wang, Tong Hong
    Wu, Kuan-Te
    MICROELECTRONIC ENGINEERING, 2008, 85 (07) : 1616 - 1623
  • [4] Adaptive semi-empirical model for non-contact atomic force microscopy
    Chen, Xi
    Tong, Jun-Kai
    Hu, Zhi-Xin
    CHINESE PHYSICS B, 2022, 31 (08)
  • [5] Simulation of section curve by phase constant dynamic mode atomic force microscopy in non-contact situation
    Nanjo, H
    Nony, L
    Yoneya, M
    Aimé, JP
    APPLIED SURFACE SCIENCE, 2003, 210 (1-2) : 49 - 53
  • [6] Visualisation of an ultrafiltration membrane by non-contact atomic force microscopy at single pore resolution
    Bowen, WR
    Hilal, N
    Lovitt, RW
    Williams, PM
    JOURNAL OF MEMBRANE SCIENCE, 1996, 110 (02) : 229 - 232
  • [7] Quantum theory of energy dissipation in non-contact atomic force microscopy in Markovian approximation
    Kantorovich, LN
    SURFACE SCIENCE, 2002, 521 (03) : 117 - 128
  • [8] The contrast mechanism for true atomic resolution by AFM in non-contact mode: Quasi-non-contact mode?
    Sokolov, IY
    Henderson, GS
    Wicks, FJ
    SURFACE SCIENCE, 1997, 381 (01) : L558 - L562
  • [9] Resolving Intra- and Inter-Molecular Structure with Non-Contact Atomic Force Microscopy
    Jarvis, Samuel Paul
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2015, 16 (08) : 19936 - 19959
  • [10] Non-contact lateral force microscopy
    Weymouth, A. J.
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2017, 29 (32)