Novel chloride-selective optode based on polymer-stabilised emulsions doped with a lipophilic fluorescent polarity-sensitive dye

被引:27
作者
Huber, C [1 ]
Werner, T [1 ]
Krause, C [1 ]
Wolfbeis, OS [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
关键词
D O I
10.1039/a905260g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chloride-selective optode is presented which is based on a polymer-stabilised emulsion system consisting of a hydrogel with entrapped plasticizer droplets. The droplets contain a neutral chloride-selective ionophore and a polarity-sensitive cationic fluorescent dye (PSD) located near the droplet surface. The ionophore extracts chloride out of the aqueous solution through the hydrogel into the plasticizer droplets, followed by a displacement of the positively charged PSD into the plasticizer droplet. This concerted process causes a decrease of micro-polarity near the dye, resulting in a dramatic increase in its fluorescence intensity. The sensing scheme can be used for reversible sensing of chloride in the 1-80 mM concentration range with response times on the order of less than 3 min. The sensor membrane has been investigated in terms of signal change, stability, limits of detection and selectivity for the analyte over interferents.
引用
收藏
页码:1617 / 1622
页数:6
相关论文
共 31 条
[21]  
Perrin D., 2012, Buffers for pH and metal ion control
[22]   Response mechanism of anion-selective electrodes based on mercury organic compounds as ionophores [J].
Rothmaier, M ;
Schaller, U ;
Morf, WE ;
Pretsch, E .
ANALYTICA CHIMICA ACTA, 1996, 327 (01) :17-28
[23]   CHLORIDE-SELECTIVE ELECTRODES BASED ON MERCURY ORGANIC-COMPOUNDS AS NEUTRAL CARRIERS [J].
ROTHMAIER, M ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1993, 271 (01) :135-141
[24]  
SCHWARZ C, 1995, J NEUROSCI, V15, P3475
[25]  
Stoy V A, 1989, J Biomater Appl, V3, P552
[26]  
TAN SSS, 1989, CHIMIA, V43, P257
[27]   REVERSIBLE OPTICAL SENSING MEMBRANE FOR THE DETERMINATION OF CHLORIDE IN SERUM [J].
TAN, SSS ;
HAUSER, PC ;
WANG, KM ;
FLURI, K ;
SEILER, K ;
RUSTERHOLZ, B ;
SUTER, G ;
KRUTTLI, M ;
SPICHIGER, UE ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1991, 255 (01) :35-44
[28]  
TIETZ NW, 1976, FUNDAMENTALS CLIN CH, P879
[29]   ANION-SELECTIVE OPTICAL SENSING WITH METALLOPORPHYRIN-DOPED POLYMERIC FILMS [J].
WANG, EJ ;
MEYERHOFF, ME .
ANALYTICA CHIMICA ACTA, 1993, 283 (02) :673-682
[30]   Fiber optic ion-microsensors based on luminescence lifetime [J].
Werner, T ;
Klimant, I ;
Huber, C ;
Krause, C ;
Wolfbeis, OS .
MIKROCHIMICA ACTA, 1999, 131 (1-2) :25-28