The Use of a Milli-whistle as a Detector in Gas Analysis by Gas Chromatography

被引:1
作者
Lin, Cheng-Huang [1 ]
He, Yi-San [1 ]
Lin, Chien-Hung [1 ]
Fan, Gang-Ting [1 ]
Chen, Hsin-Kai [1 ]
机构
[1] Natl Taiwan Normal Univ, Dept Chem, Taipei, Taiwan
关键词
Whistle; gas chromatography; microphone; accelerometer; TRANSFORM INFRARED SPECTROMETRY; FLOW-INJECTION ANALYSIS; SULFUR-DIOXIDE; AMMONIA-BORANE; PULMONARY-EMBOLISM; MASS-SPECTROMETRY; D-DIMER; HYDROGEN; AIR; PHASE;
D O I
10.2116/analsci.30.183
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This mini-review introduces a general understanding of the use of a milli-whistle as a gas chromatography (GC) detector in gas analysis, including our research on the methodology and theory associated with a number of different related applications. The milli-whistle is connected to the outlet of a GC capillary, and when the eluted gases and the GC carrier gas pass through it, a sound with a fundamental frequency is produced. The sound wave can be picked up by a microphone or an accelerometer, and after a fast Fourier transform, the online data obtained for frequency-change vs. retention time constitute a new method for detecting gases. The first part of this review discusses the fundamentals of the milli-whistle. Some modifications are also discussed, including various types of whistles and an attempt to maximize the sensitivity and stability of the method. The second part then focuses on several practical applications, including an analysis of hydrogen released from ammonia borane, inorganic gases produced from fireworks, the CO2/O-2 ratio from expired human breath and a purity test for alcohols. These studies show that the GC-whistle method has great potential for use as a fast sampling ionization method, and for the direct analysis of biological and chemical samples at under ambient conditions.
引用
收藏
页码:183 / 191
页数:9
相关论文
共 43 条
[1]  
Amster IJ, 1996, J MASS SPECTROM, V31, P1325
[2]   Thermal decomposition of B-N-H compounds investigated by using combined thermoanalytical methods [J].
Baitalow, F ;
Baumann, J ;
Wolf, G ;
Jaenicke-Rössler, K ;
Leitner, G .
THERMOCHIMICA ACTA, 2002, 391 (1-2) :159-168
[3]  
Benton W. E., 1925, P PHYS SOC LOND, V38, P109
[4]   A NEW TYPE OF ARGON IONIZATION DETECTOR [J].
BERES, SA ;
HALFMANN, CD ;
KATZ, ED ;
SCOTT, RPW .
ANALYST, 1987, 112 (01) :91-95
[5]   PERFORMANCE-CHARACTERISTICS OF A REAL-TIME DIRECT DEPOSITION GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SPECTROMETRY SYSTEM [J].
BOURNE, S ;
HAEFNER, AM ;
NORTON, KL ;
GRIFFITHS, PR .
ANALYTICAL CHEMISTRY, 1990, 62 (22) :2448-2452
[6]  
Brown G.B., 1937, P PHYS SOC, V49, P493, DOI 10.1088/0959-5309/49/5/306
[7]   Screening of inorganic gases released from firework-rockets by a gas chromatography/whistle-accelerometer method [J].
Chen, Kuan-Fu ;
Wu, Hui-Hsin ;
Lin, Chien-Hung ;
Lin, Cheng-Huang .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1305 :230-233
[8]   A new method for atmospheric nitrogen dioxide measurements using the combination of a stripping coil and fluorescence detection [J].
Chen, XY ;
Oro, Y ;
Tanaka, K ;
Takenaka, N ;
Bandow, H .
ANALYTICAL SCIENCES, 2004, 20 (07) :1019-1023
[9]   Highly sensitive and linear optical fiber carbon dioxide sensor based on sol-gel matrix doped with silica particles and HPTS [J].
Chu, Chen-Shane ;
Lo, Yu-Lung .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 143 (01) :205-210
[10]   Nanoscaffold mediates hydrogen release and the reactivity of ammonia borane [J].
Gutowska, A ;
Li, LY ;
Shin, YS ;
Wang, CMM ;
Li, XHS ;
Linehan, JC ;
Smith, RS ;
Kay, BD ;
Schmid, B ;
Shaw, W ;
Gutowski, M ;
Autrey, T .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2005, 44 (23) :3578-3582