Clinical Application of Shear Wave Elastography in Breast Masses

被引:1
作者
Chang, Jin Young [1 ]
Moon, Jin Hee [1 ]
Koh, Sung Hye [1 ]
Park, Sun-Young [1 ]
Lee, Kwan Seop [1 ]
机构
[1] Hallym Sacred Heart Hosp, Anyang, South Korea
关键词
Breast; Ultrasound; Elastography; Shear Wave; Solid Mass; ULTRASOUND ELASTOGRAPHY; LESIONS; BENIGN; DIAGNOSIS; US; SONOGRAPHY; DIFFERENTIATION; FEATURES;
D O I
10.5812/iranjradiol.39585
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Quantitative shear wave elastography (SWE) has been developed and utilized to aid in the differentiation between benign and malignant breast lesions based on their stiffness. Objectives: The purpose of this study was to evaluate the clinical effects of the additional use of SWE to conventional ultrasound (US) according to the maximum (Emax) and mean (Emean) elasticitiy values. Patients and Methods: A total 115 patients with 133 lesions were assessed using conventional US and SWE. All patients underwent US-guided core needle biopsy or surgery, and the pathological results were used as reference standards. We compared the diagnostic values including sensitivities, specificities, positive predictive values (PPVs) and negative predictive values (NPVs) and accuracies of conventional US and SWE according to the E-max and E-mean values. Next, we obtained the optimal E-max and E-mean cutoff values for SWE. Using these cutoff values, we analyzed the clinical effects of the additional use of SWE to conventional US based on the corrected results. Results: Of the 133 breast lesions, 32 were malignant and 101 were benign. In the differentiation of benign and malignant lesions, conventional US resulted in sensitivity of 100 %, specificity of 43.0 %, PPV of 57.1 %, NPV of 36.7 %, and accuracy of 100 %. Regarding SWE, the sensitivity, specificity, PPV, NPV, and accuracy values based on E-max were 84.4 %, 89.1 %, 71.1 %, 94.7 %, and 88.0 %, respectively, and the corresponding values based on E-mean were 84.8 %, 93.0 %, 91.0 %, 80.0 %, and 94.9 %, respectively. The optimal E-max and E-mean cutoff values were 81.3 and 60.7 kPa, respectively. However, there was no significant difference between E-max and E-mean. The corrected results related to the additional use of SWE to conventional US indicated 97.0 % sensitivity, 93.0 % specificity, 82.1 % PPV, 98.9 % NPV, and 94.0 % accuracy (P < 0.0001). Conclusion: The additional use of SWE to conventional US resulted in marked improvements in specificity, PPV, and accuracy and slight diminutions in sensitivity and NPV for the differentiation benign and malignant breast lesions. Both E-max and E-mean were effective diagnostic parameters, and there was no significant difference between these two parameters.
引用
收藏
页数:8
相关论文
共 30 条
[1]  
American College of Radiology, 2003, BREAST IM REP DAT SY, P98
[2]   Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging-Preliminary Results [J].
Athanasiou, Alexandra ;
Tardivon, Anne ;
Tanter, Mickael ;
Sigal-Zafrani, Brigitte ;
Bercoff, Jeremy ;
Eux, Thomas Deffi ;
Gennisson, Jean-Luc ;
Fink, Mathias ;
Neuenschwander, Sylvia .
RADIOLOGY, 2010, 256 (01) :297-303
[3]   Supersonic shear imaging: A new technique for soft tissue elasticity mapping [J].
Bercoff, J ;
Tanter, M ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) :396-409
[4]   Shear-wave Elastography Improves the Specificity of Breast US: The BE1 Multinational Study of 939 Masses [J].
Berg, Wendie A. ;
Cosgrove, David O. ;
Dore, Caroline J. ;
Schaefer, Fritz K. W. ;
Svensson, William E. ;
Hooley, Regina J. ;
Ohlinger, Ralf ;
Mendelson, Ellen B. ;
Balu-Maestro, Catherine ;
Locatelli, Martina ;
Tourasse, Christophe ;
Cavanaugh, Barbara C. ;
Juhan, Valerie ;
Stavros, A. Thomas ;
Tardivon, Anne ;
Gay, Joel ;
Henry, Jean-Pierre ;
Cohen-Bacrie, Claude .
RADIOLOGY, 2012, 262 (02) :435-449
[5]   Differentiating benign from malignant solid breast masses with US strain imaging [J].
Burnside, Elizabeth S. ;
Hall, Timothy J. ;
Sommer, Amy M. ;
Hesley, Gina K. ;
Sisney, Gale A. ;
Svensson, William E. ;
Fine, Jason P. ;
Jiang, Jinfeng ;
Hangiandreou, Nicholas J. .
RADIOLOGY, 2007, 245 (02) :401-410
[6]   Clinical application of shear wave elastography (SWE) in the diagnosis of benign and malignant breast diseases [J].
Chang, Jung Min ;
Moon, Woo Kyung ;
Cho, Nariya ;
Yi, Ann ;
Koo, Hye Ryoung ;
Han, Wonsik ;
Noh, Dong-Young ;
Moon, Hyeong-Gon ;
Kim, Seung Ja .
BREAST CANCER RESEARCH AND TREATMENT, 2011, 129 (01) :89-97
[7]   Breast Mass Evaluation: Factors Influencing the Quality of US Elastography [J].
Chang, Jung Min ;
Moon, Woo Kyung ;
Cho, Nariya ;
Kim, Seung Ja .
RADIOLOGY, 2011, 259 (01) :59-64
[8]  
Ciurea AI., 2011, Ultraschall Med, V32, pS27S34, DOI DOI 10.1055/S-0029-1245684
[9]   Quantitative shear wave ultrasound elastography: initial experience in solid breast masses [J].
Evans, Andrew ;
Whelehan, Patsy ;
Thomson, Kim ;
McLean, Denis ;
Brauer, Katrin ;
Purdie, Colin ;
Jordan, Lee ;
Baker, Lee ;
Thompson, Alastair .
BREAST CANCER RESEARCH, 2010, 12 (06)
[10]   Elastography of breast lesions: Initial clinical results [J].
Garra, BS ;
Cespedes, EI ;
Ophir, J ;
Spratt, SR ;
Zuurbier, RA ;
Magnant, CM ;
Pennanen, MF .
RADIOLOGY, 1997, 202 (01) :79-86