Reliable laboratory urinalysis results using a new standardised urine collection device

被引:5
|
作者
Roelofs-Thijssen, Myriam A. M. A. [1 ]
Schreuder, Michiel F. [2 ]
Hogeveen, Marije [3 ]
van Herwaarden, Antonius E. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Lab Med, Clin Chem Lab, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Paediat Nephrol, NL-6500 HB Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Dept Neonatol, NL-6500 HB Nijmegen, Netherlands
关键词
Urine collection; Urinalysis; Urine stick; Quantitative; Urine biochemistry; YOUNG-CHILDREN; TRACT-INFECTION; CONTAMINATION RATES; DIAGNOSIS; INFANTS; PADS; BIOCHEMISTRY; RELIABILITY;
D O I
10.1016/j.clinbiochem.2013.04.014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: While urine sampling is necessary in the diagnosis of urinary tract infection and electrolyte disturbances, the collection of urine in neonates and non-toilet-trained children is often difficult. A universal urine collection method providing representative urinalyses results is needed. The objective of this study is to evaluate the applicability of the currently used urine collection pads (gauze compresses) and a new urine collection device (Peespot). Design and methods: We tested the reliability of routine (semi-)quantitative urinalysis results with these two different kinds of urine collection methods in a laboratory model. Although important in clinical diagnosis, we did not evaluate the effects on cellular and other components such as casts in the urinary sediment. Results: Most semi-quantitative variables determined by urine stick (pH, blood, protein, leukocytes, nitrite, glucose, ketones, bilirubin and urobilinogen) gave concordant results for both methods compared with native urine. Using the Peespot urine collection device, reliable quantitative results were obtained for calcium, chloride, glucose, magnesium, phosphate, potassium, sodium, osmolality, urea nitrogen and urate compared with native urine. Data were concordant only for chloride, phosphate, glucose, sodium and urea nitrogen by use of gauze compresses. Conclusions: Urine collection pads are non-invasive methods useful in the collection of urine in non-toilet-trained children. Because of better practical standardisation and more reliable (semi-) quantitative urinalysis results, the Peespot urine collection device is preferred for the collection of urine. (c) 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1252 / 1256
页数:5
相关论文
共 7 条
  • [1] Beyond urinalysis: evaluation of various clinical and laboratory reflex criteria to warrant urine culture collection in the emergency department
    Alateeq, Nada M.
    Mohammed, Manal B.
    Alsubaie, Albandari T.
    Alshehri, Amal A.
    Attallah, Dalya
    Agabawi, Salem
    Thabit, Abrar K.
    INTERNATIONAL JOURNAL OF EMERGENCY MEDICINE, 2024, 17 (01)
  • [2] The automation of sediment urinalysis using a new urine flow cytometer (UF-100™)
    Fenili, D
    Pirovano, B
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (12) : 909 - 917
  • [3] Pediatric reference values for urine particle quantification by using automated flow cytometer: Results of a multicenter study of Italian urinalysis group
    Manoni, Fabio
    Gessoni, Gianluca
    Caleffi, Alberta
    Alessio, Maria Grazia
    Rosso, Roberto
    Menozzi, Patrizia
    Tinello, Agostino
    Valverde, Sara
    Azzara, Giovanna
    Lippi, Giuseppe
    CLINICAL BIOCHEMISTRY, 2013, 46 (18) : 1820 - 1824
  • [4] Using results of new laboratory test for tuberculosis infection in children
    Kryvasheyeva, Zhanna
    Astrovko, Andrey
    Emeljanova, Natalia
    Babchenok, Irina
    Morozkina, Natalya
    Baradzina, Galina
    Krivonos, Pavel
    Pylishev, Valeriy
    Bobrukevich, Elena
    Belko, Anna
    EUROPEAN RESPIRATORY JOURNAL, 2013, 42
  • [5] Pilot Trial of Midstream Urine Collection Device Versus Transurethral Catheter in Women With Lower Urinary Tract Symptoms: Practicality of Use in a Clinical Setting, Patient Preferences, and Comparison of Laboratory Findings
    High, Rachel
    Zhang, Yu
    Virani, Shohaib
    Eggleston, Kimberly
    Kuehl, Thomas J.
    Bird, Erin T.
    Danford, Jill M.
    FEMALE PELVIC MEDICINE AND RECONSTRUCTIVE SURGERY, 2021, 27 (06): : 371 - 376
  • [6] Wearable pendant device monitoring using new wavelet-based methods shows daily life and laboratory gaits are different
    Brodie, Matthew A. D.
    Coppens, Milou J. M.
    Lord, Stephen R.
    Lovell, Nigel H.
    Gschwind, Yves J.
    Redmond, Stephen J.
    Del Rosario, Michael Benjamin
    Wang, Kejia
    Sturnieks, Daina L.
    Persiani, Michela
    Delbaere, Kim
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (04) : 663 - 674
  • [7] Comparison of the Efficacy and Safety of Pulp Sensitivity Testing Results Using a New Pulp Testing Device versus Some Commonly Used Methods: A Crossover Study
    Tordik, Patricia A.
    Torabinejad, Mahmoud
    Fevelo, Cassandra M.
    Oyoyo, Udochukwu
    JOURNAL OF ENDODONTICS, 2024, 50 (01) : 22 - 30