Is uniform target dose possible in IMRT plans in the head and neck?

被引:62
作者
Vineberg, KA [1 ]
Eisbruch, A [1 ]
Coselmon, MM [1 ]
McShan, DL [1 ]
Kessler, ML [1 ]
Fraass, BA [1 ]
机构
[1] Univ Michigan, Med Ctr, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 52卷 / 05期
关键词
intensity-modulated radiotherapy; IMRT; head-and-neck cancer; parotid-sparing; conformal radiotherapy; 3D planning; dose escalation; optimization;
D O I
10.1016/S0360-3016(01)02800-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., +/-5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose calculation and flexible cost functions derived from combinations of clinically relevant factors (costlets) that can include dose, dose-volume, and biologic model-based costlets. The current study compared optimized IMRT plans designed to treat the various planning target volumes to doses of 66, 60, and 54 Gy with varying target dose homogeneity while using a flexible optimization cost function to minimize the dose to the parotids, spinal cord, oral cavity, brainstem, submandibular nodes, and other structures. Results: In all cases, target dose uniformity was achieved through steeply varying dose-based costs. Differences in clinical plan evaluation metrics were evaluated for individual cases (eight different target homogeneity costlets), and for the entire cohort of plans. Highly conformal plans were achieved, with significant sparing of both the contralateral and ipsilateral parotid glands. As the homogeneity of the target dose distributions was allowed to decrease, increased sparing of the parotids (and other normal tissues) may be achieved. However, it was shown that relatively few patients would benefit from the use of increased target inhomogeneity, because the range of improvement in the parotid dose is relatively limited. Hot spots in the target volumes are shown to be unnecessary and do not assist in normal tissue sparing. Conclusion: Sparing of both parotids in patients receiving bilateral neck radiation can be achieved without compromising strict target dose homogeneity criteria. The geometry of the normal tissue and target anatomy are shown to be the major factor necessary to predict the parotid sparing that will be possible for any particular case. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:1159 / 1172
页数:14
相关论文
共 37 条
  • [1] QUALITY-OF-LIFE IN PATIENTS TREATED FOR HEAD AND NECK-CANCER - A FOLLOW-UP-STUDY 7 TO 11 YEARS AFTER RADIOTHERAPY
    BJORDAL, K
    KAASA, S
    MASTEKAASA, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (04): : 847 - 856
  • [2] X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS
    BORTFELD, TR
    KAHLER, DL
    WALDRON, TJ
    BOYER, AL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03): : 723 - 730
  • [3] Modulated beam conformal therapy for head and neck tumors
    Boyer, AL
    Geis, P
    Grant, W
    Carol, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01): : 227 - 236
  • [4] Smart (simultaneous modulated accelerated radiation therapy) boost: A new accelerated fractionation schedule for the treatment of head and neck cancer with intensity modulated radiotherapy
    Butler, EB
    Teh, BS
    Grant, WH
    Uhl, BM
    Kuppersmith, RB
    Chiu, JK
    Donovan, DT
    Woo, SY
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (01): : 21 - 32
  • [5] Chao KSC, 2000, INT J CANCER, V90, P92, DOI 10.1002/(SICI)1097-0215(20000420)90:2<92::AID-IJC5>3.0.CO
  • [6] 2-9
  • [7] Clinical delivery of intensity modulated conformal radiotherapy for relapsed or second-primary head and neck cancer using a multileaf collimator with dynamic control
    De Neve, W
    De Gersem, W
    Derycke, S
    De Meerleer, G
    Moerman, M
    Bate, MT
    Van Duyse, B
    Vakaet, L
    De Deene, Y
    Mersseman, B
    De Wagter, C
    [J]. RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) : 301 - 314
  • [8] Leaf trajectory calculation for dynamic multileaf collimation to realize optimized fluence profiles
    Dirkx, MLP
    Heijmen, BJM
    van Santvoort, JPC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) : 1171 - 1184
  • [9] Xerostomia and its predictors following parotid-sparing irradiation of head-and-neck cancer
    Eisbruch, A
    Kim, HM
    Terrell, JE
    Marsh, LH
    Dawson, LA
    Ship, JA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (03): : 695 - 704
  • [10] Comprehensive irradiation of head and neck cancer using conformal multisegmental fields: Assessment of target coverage and noninvolved tissue sparing
    Eisbruch, A
    Marsh, LH
    Martel, MK
    Ship, JA
    Ten Haken, R
    Pu, AT
    Fraass, BA
    Lichter, AS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (03): : 559 - 568