Grey Wolf Optimization-Based Optimum Energy-Management and Battery-Sizing Method for Grid-Connected Microgrids

被引:61
作者
Nimma, Kutaiba Sabah [1 ]
Al-Falahi, Monaaf D. A. [1 ]
Hung Duc Nguyen [1 ]
Jayasinghe, S. D. G. [1 ]
Mahmoud, Thair S. [2 ]
Negnevitsky, Michael [3 ,4 ]
机构
[1] Univ Tasmania, Australian Maritime Coll, Newnham, Tas 7248, Australia
[2] Edith Cowan Univ, Sch Engn, Joondalup, WA 6027, Australia
[3] Univ Tasmania, Ctr Renewable Energy, Hobart, Tas 7005, Australia
[4] Univ Tasmania, Power Syst Sch Engn, Hobart, Tas 7005, Australia
关键词
battery energy storage sizing; optimization; energy management systems; economic load dispatch; grey wolf optimization (GWO); microgrid; STORAGE SYSTEM; ION BATTERIES; ALGORITHM; SOLAR; SIZE; GENERATION; STRATEGIES; ALLOCATION; OPERATION; MODEL;
D O I
10.3390/en11040847
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the revolution of green energy development, microgrids with renewable energy sources such as solar, wind and fuel cells are becoming a popular and effective way of controlling and managing these sources. On the other hand, owing to the intermittency and wide range of dynamic responses of renewable energy sources, battery energy-storage systems have become an integral feature of microgrids. Intelligent energy management and battery sizing are essential requirements in the microgrids to ensure the optimal use of the renewable sources and reduce conventional fuel utilization in such complex systems. This paper presents a novel approach to meet these requirements by using the grey wolf optimization (GWO) technique. The proposed algorithm is implemented for different scenarios, and the numerical simulation results are compared with other optimization methods including the genetic algorithm (GA), particle swarm optimization (PSO), the Bat algorithm (BA), and the improved bat algorithm (IBA). The proposed method (GWO) shows outstanding results and superior performance compared with other algorithms in terms of solution quality and computational efficiency. The numerical results show that the GWO with a smart utilization of battery energy storage (BES) helped to minimize the operational costs of microgrid by 33.185% in comparison with GA, PSO, BA and IBA.
引用
收藏
页数:27
相关论文
共 41 条
[1]   A new approach for optimal sizing of battery energy storage system for primary frequency control of islanded Microgrid [J].
Aghamohammadi, Mohammad Reza ;
Abdolahinia, Hajar .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 54 :325-333
[2]   Application of the Hybrid Big Bang-Big Crunch algorithm for optimal sizing of a stand-alone hybrid PV/wind/battery system [J].
Ahmadi, Saeedeh ;
Abdi, Shirzad .
SOLAR ENERGY, 2016, 134 :366-374
[3]   A review on recent size optimization methodologies for standalone solar and wind hybrid renewable energy system [J].
Al-Falahi, Monaaf D. A. ;
Jayasinghe, S. D. G. ;
Enshaei, H. .
ENERGY CONVERSION AND MANAGEMENT, 2017, 143 :252-274
[4]  
ALFAKIH M, 2015, 2015 3 INT C CONTR E, P1
[5]  
[Anonymous], 2016, 2016 IEEE 2 ANN SO P
[6]   Optimal sizing of battery energy storage for micro-grid operation management using a new improved bat algorithm [J].
Bahmani-Firouzi, Bahman ;
Azizipanah-Abarghooee, Rasoul .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 56 :42-54
[7]   Operation, sizing, and economic evaluation of storage for solar and wind power plants [J].
Berrada, Asmae ;
Loudiyi, Khalid .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 59 :1117-1129
[8]   Robust optimal sizing of a hybrid energy stand-alone system [J].
Billionnet, Alain ;
Costa, Marie-Christine ;
Poirion, Pierre-Louis .
EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2016, 254 (02) :565-575
[9]   Optimal sizing of hybrid solar micro-CHP systems for the household sector [J].
Brandoni, Caterina ;
Renzi, Massimiliano .
APPLIED THERMAL ENGINEERING, 2015, 75 :896-907
[10]   A heuristic approach for optimal sizing of ESS coupled with intermittent renewable sources systems [J].
Bridier, Laurent ;
Hernandez-Torres, David ;
David, Mathieu ;
Lauret, Phillipe .
RENEWABLE ENERGY, 2016, 91 :155-165