Measurement of nitrogen dioxide in cigarette smoke using quantum cascade tunable infrared laser differential absorption spectroscopy (TILDAS)

被引:17
作者
Shorter, JH
Nelson, DD
Zahniser, MS
Parrish, ME
Crawford, DR
Gee, DL
机构
[1] Aerodyne Res Inc, Billerica, MA 01821 USA
[2] Philip Morris Inc, Res Ctr, Richmond, VA 23234 USA
关键词
cigarette smoke; infrared spectroscopy; nitrogen dioxide; quantum cascade laser;
D O I
10.1016/j.saa.2005.11.005
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Although nitrogen dioxide (NO2) has been previously reported to be present in cigarette smoke, the concentration estimates were derived from kinetic calculations or from measurements of aged smoke, where NO2 was formed some time after the puff was taken. The objective of this work was to use tunable infrared laser differential absorption spectroscopy (TILDAS) equipped with a quantum cascade (QC) laser to determine if NO2 could be detected and quantified in a fresh puff of cigarette smoke. A temporal resolution of similar to 0.16 s allowed measurements to be taken directly as the NO2 was formed during the puff. Sidestream cigarette smoke was sampled to determine if NO2 could be detected using TILDAS. Experiments were conducted using 2R4F Kentucky Reference cigarettes with and without a Cambridge filter pad. NO2 was detected only in the lighting puff of whole mainstream smoke (without a Cambridge filter pad), with no NO2 detected in the subsequent puffs. The measurement precision was similar to 1.0 ppbV Hz(-1/2), which allows a detection limit of similar to 0.2 ng in a 35 ml puff volume. More NO2 was generated in the lighting puff using a match or blue flame lighter (29 +/- 21 ng) than when using an electric lighter (9 +/- 3 ng). In the presence of a Cambridge filter pad, NO2 was observed in the gas phase mainstream smoke for every puff (total of 200 +/- 30 ng/cigarette) and is most likely due to smoke chemistry taking place on the Cambridge filter pad during the smoke collection process. Nitrogen dioxide was observed continuously in the sidestream smoke starting with the lighting puff. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:994 / 1001
页数:8
相关论文
共 50 条
  • [31] Fast simultaneous measurement of multi-gases using quantum cascade laser photoacoustic spectroscopy
    W. Liu
    L. Wang
    L. Li
    J. Liu
    F.-Q. Liu
    Z. Wang
    Applied Physics B, 2011, 103 : 743 - 747
  • [32] Ammonia detection using hollow waveguide enhanced laser absorption spectroscopy based on a 9.56 μm quantum cascade laser
    Li Jinyi
    Yang Sen
    Wang Ruixue
    Du Zhenhui
    Wei Yingying
    AOPC 2017: OPTICAL SPECTROSCOPY AND IMAGING, 2017, 10461
  • [33] Approach of high-speed glucose detection using quantum cascade laser-based mid-infrared spectroscopy
    Chen, Junyi
    Furukawa, Hiromitsu
    OPTICAL DIAGNOSTICS AND SENSING XXIV:TOWARD POINT-OF-CARE DIAGNOSTICS, 2024, 12850
  • [34] Broadband Mid-Infrared Stand-Off Reflection-Absorption Spectroscopy Using a Pulsed External Cavity Quantum Cascade Laser
    Liu, Xunchen
    Chae, Inseok
    Miriyala, Naresh
    Lee, Dongkyu
    Thundat, Thomas
    Kim, Seonghwan
    APPLIED SPECTROSCOPY, 2017, 71 (07) : 1494 - 1505
  • [35] In-flight stability of quantum cascade laser-based infrared absorption spectroscopy measurements of atmospheric carbon monoxide
    Ivan Tadic
    Uwe Parchatka
    Rainer Königstedt
    Horst Fischer
    Applied Physics B, 2017, 123
  • [36] Near-infrared tunable diode laser absorption spectroscopy-based determination of carbon dioxide in human exhaled breath
    Lou, Cunguang
    Jing, Congrui
    Wang, Xin
    Chen, Yuhao
    Zhang, Jiantao
    Hou, Kaixuan
    Yao, Jianquan
    Liu, Xiuling
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (11) : 5486 - 5496
  • [37] Simultaneous measurements of atmospheric HONO and NO2 via absorption spectroscopy using tunable mid-infrared continuous-wave quantum cascade lasers
    B. H. Lee
    E. C. Wood
    M. S. Zahniser
    J. B. McManus
    D. D. Nelson
    S. C. Herndon
    G. W. Santoni
    S. C. Wofsy
    J. W. Munger
    Applied Physics B, 2011, 102 : 417 - 423
  • [38] First pressure shift measurement of ozone molecular lines at 9.54 μm using a tunable quantum cascade laser
    Minissale, Marco
    Zanon-Willette, Thomas
    Jeseck, Pascal
    Boursier, Corinne
    Janssen, Christof
    JOURNAL OF MOLECULAR SPECTROSCOPY, 2018, 348 : 103 - 113
  • [39] A reliable method for the isolation and characterization of microplastics in fish gastrointestinal tracts using an infrared tunable quantum cascade laser system
    Lopez-Rosales, Adrian
    Andrade, Jose
    Fernandez-Gonzalez, Veronica
    Lopez-Mahia, Purificacion
    Muniategui-Lorenzo, Soledad
    MARINE POLLUTION BULLETIN, 2022, 178
  • [40] HONO and N2O4 Measurement Method Based on Mid-Infrared Quantum Cascade Laser Spectroscopy
    Li Yafan
    Jiang Chaochao
    Cui Xiaohan
    Yu Benli
    Cui Xiaojuan
    ACTA OPTICA SINICA, 2023, 43 (11)