Correlation between gamma passing rate and complexity of IMRT plan due to MLC position errors

被引:28
|
作者
Wang, Yewei [1 ]
Pang, Xueying [2 ]
Feng, Lina [1 ]
Wang, Helong [1 ]
Bai, Yanling [1 ]
机构
[1] Harbin Med Univ, Affiliated Tumor Hosp, Dept Radiat Phys, Baojian Rd 6, Harbin 150081, Heilongjiang, Peoples R China
[2] Heilongjiang Univ Chinese Med, Affiliated Hosp 1, Dept Oncol, Harbin, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
ArcCHECK; Gamma passing rate; MLC; Complexity; DELIVERY ERRORS; DYNAMIC IMRT; QA SYSTEMS; SENSITIVITY; ACCURACY; IMPACT; VMAT; VERIFICATION; RADIOTHERAPY; QUALITY;
D O I
10.1016/j.ejmp.2018.03.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study evaluates the correlation between the susceptibility of the gamma passing rate of IMRT plans to the multi-leaf collimator (MLC) position errors and a quantitative plan complexity metric. Methods: Twenty patients were selected for this study. For each patient, two IMRT plans were generated using sliding window and step-&-shoot techniques, respectively. Modulation complexity score (MCS) was calculated for all IMRT plans, and symmetric MLC leaf bank errors, ranging from 0.3mm to 1 mm, were introduced. Original and modified plans were delivered using Varian's Clinac iX. The obtained dose distribution using ArcCHECK was then compared with the TPS calculated dose distribution of the original plans. 3D gamma analysis was performed for each verification with passing criteria of 2%/2 mm. The gamma passing rate decreasing gradient were calculated to evaluate relationship between variation of gamma passing rate due to MLC errors and complexity. Results: A linear regression analysis was applied between gamma gradient and complexity, and the results showed a linear correlation (R-2=0.81 and 0.82 for open and closed MLC error types, respectively) indicating the more complex plans are more susceptible to MLC leaf bank errors. Meanwhile, correlation of re-normalized gamma passing rate and complexity for all errors scenarios also presented a strong correlation (r > 0.75). Conclusion: The statistics results revealed variation relationship of dosimetry robust of plans with various complexities to MLC errors. Our results also suggested that the observed susceptibility is independent of the delivery techniques.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 50 条
  • [31] Can 2D Gamma-Passing Rate Predict DVH Errors? Analysis of Gamma-Passing Rate Based VMAT QA
    Bedoya, M.
    Wilke, C.
    Watanabe, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E607 - E607
  • [32] Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures
    Mavroidis, Panayiotis
    Ferreira, Brigida Costa
    Shi, Chengyu
    Lind, Bengt K.
    Papanikolaou, Nikos
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (13): : 3817 - 3836
  • [33] Plan complexity and dosiomics signatures for gamma passing rate classification in volumetric modulated arc therapy: External validation across different LINACs
    Li, Chao
    Su, Zhuo
    Li, Bing
    Sun, Wenzheng
    Wu, Dang
    Zhang, Yizhe
    Li, Xia
    Xie, Zejun
    Huang, Jing
    Wei, Qichun
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2025, 133
  • [34] Predictive Gamma Passing Rate Based On Dose Uncertainty for Head-And-Neck and Prostate IMRT
    Shiba, E.
    Saito, A.
    Tsuneda, M.
    Furumi, M.
    Yahara, K.
    Ohguri, T.
    Murakami, Y.
    Nishio, T.
    Korogi, Y.
    Nagata, Y.
    MEDICAL PHYSICS, 2018, 45 (06) : E282 - E282
  • [35] Evaluation of DVH-based treatment plan verification in addition to gamma passing rates for head and neck IMRT
    Visser, Ruurd
    Wauben, David J. L.
    de Groot, Martijn
    Steenbakkers, Roel J. H. M.
    Bijl, Henk P.
    Godart, Jeremy
    van't Veld, Aart A.
    Langendijk, Johannes A.
    Korevaar, Erik W.
    RADIOTHERAPY AND ONCOLOGY, 2014, 112 (03) : 389 - 395
  • [36] Temporal correlation in Monte Carlo sampling to evaluate interplay between tumor and MLC motion in IMRT
    Naqvi, S.
    D'Souza, W.
    MEDICAL PHYSICS, 2006, 33 (06) : 2139 - 2139
  • [37] Effect of Minimum Segment Width on Gamma Passing Rate Considering MLC Position Error for Volumetric Modulated Arc Therapy (vol 74, pg 724, 2019)
    Moon, Young Min
    Bae, Sang Il
    Choi, Chul Won
    Jeon, Wan
    Kim, Jin Young
    Lee, Man Woo
    Ro, Tae-Ik
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 74 (09) : 912 - 912
  • [38] Study of the prediction of gamma passing rate in dosimetric verification of intensity-modulated radiotherapy using machine learning models based on plan complexity
    Bin, Shizhen
    Zhang, Ji
    Shen, Luyao
    Zhang, Junjun
    Wang, Qi
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [39] Correlation between IMRT plan and delivery quality for 9 treatment planning systems
    Olch, A
    Chopra, K
    Jiang, Z
    Mitra, R
    Hasson, B
    Chang, S
    Cheng, C
    Das, I
    MEDICAL PHYSICS, 2005, 32 (06) : 1981 - 1981
  • [40] A Correlation Study of 2D and 3D Gamma Passing Rates for Prostate IMRT Plans
    Zhang, D.
    Wang, B.
    Deng, X.
    Ma, C.
    MEDICAL PHYSICS, 2015, 42 (06) : 3335 - 3335