Correlation between gamma passing rate and complexity of IMRT plan due to MLC position errors

被引:28
|
作者
Wang, Yewei [1 ]
Pang, Xueying [2 ]
Feng, Lina [1 ]
Wang, Helong [1 ]
Bai, Yanling [1 ]
机构
[1] Harbin Med Univ, Affiliated Tumor Hosp, Dept Radiat Phys, Baojian Rd 6, Harbin 150081, Heilongjiang, Peoples R China
[2] Heilongjiang Univ Chinese Med, Affiliated Hosp 1, Dept Oncol, Harbin, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
ArcCHECK; Gamma passing rate; MLC; Complexity; DELIVERY ERRORS; DYNAMIC IMRT; QA SYSTEMS; SENSITIVITY; ACCURACY; IMPACT; VMAT; VERIFICATION; RADIOTHERAPY; QUALITY;
D O I
10.1016/j.ejmp.2018.03.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study evaluates the correlation between the susceptibility of the gamma passing rate of IMRT plans to the multi-leaf collimator (MLC) position errors and a quantitative plan complexity metric. Methods: Twenty patients were selected for this study. For each patient, two IMRT plans were generated using sliding window and step-&-shoot techniques, respectively. Modulation complexity score (MCS) was calculated for all IMRT plans, and symmetric MLC leaf bank errors, ranging from 0.3mm to 1 mm, were introduced. Original and modified plans were delivered using Varian's Clinac iX. The obtained dose distribution using ArcCHECK was then compared with the TPS calculated dose distribution of the original plans. 3D gamma analysis was performed for each verification with passing criteria of 2%/2 mm. The gamma passing rate decreasing gradient were calculated to evaluate relationship between variation of gamma passing rate due to MLC errors and complexity. Results: A linear regression analysis was applied between gamma gradient and complexity, and the results showed a linear correlation (R-2=0.81 and 0.82 for open and closed MLC error types, respectively) indicating the more complex plans are more susceptible to MLC leaf bank errors. Meanwhile, correlation of re-normalized gamma passing rate and complexity for all errors scenarios also presented a strong correlation (r > 0.75). Conclusion: The statistics results revealed variation relationship of dosimetry robust of plans with various complexities to MLC errors. Our results also suggested that the observed susceptibility is independent of the delivery techniques.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 50 条
  • [21] Erratum to: Effect of Minimum Segment Width on Gamma Passing Rate Considering MLC Position Error for Volumetric Modulated Arc Therapy
    Young Min Moon
    Sang Il Bae
    Chul Won Choi
    Wan Jeon
    Jin Young Kim
    Man Woo Lee
    Tae-Ik Ro
    Journal of the Korean Physical Society, 2019, 74 : 912 - 912
  • [22] Comparison of 3D and 2D gamma passing rate criteria for detection sensitivity to IMRT delivery errors
    Zhang, Dandan
    Wang, Bin
    Zhang, Guangshun
    Ma, Charlie
    Deng, Xiaowu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 230 - 238
  • [23] Gamma Passing Rate - Correlation with Patient Specific Quality Assurance Devices using Two Photon energies in Pelvic IMRT
    Nigam, Jitendra
    Kumar, Piyush
    Singh, P. P.
    Silambarasan, N. S.
    Navitha, S.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2022, 60 (09) : 773 - 782
  • [24] A correlation study between gamma index passing rate and clinical dose volume histogram
    Szczurek, L.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S942 - S943
  • [25] A study on the correlation between radiation field size and gamma index passing rate for MatriXX
    Xie, Kai
    Sun, Hongfei
    Gao, Liugang
    Sui, Jianfeng
    Lin, Tao
    Ni, Xinye
    MEDICINE, 2019, 98 (30)
  • [26] Development of a plan complexity mitigation algorithm based on gamma passing rate predictions for volumetric-modulated arc therapy
    Ono, Tomohiro
    Nakamura, Mitsuhiro
    Ono, Yuka
    Nakamura, Kiyonao
    Mizowaki, Takashi
    MEDICAL PHYSICS, 2022, 49 (03) : 1793 - 1802
  • [27] The effect of MLC positioning errors on plan dose distribution and gamma analysis using EPID dosimetry
    Maraghechi, Borna
    Davis, Jack
    Mitchell, Nicholas
    Shah, Meera
    Fleck, Andre
    Darko, Johnson
    Osei, Ernest
    MEDICAL PHYSICS, 2017, 44 (08) : 4377 - 4378
  • [28] Prediction of Gamma-Passing Rate Based On Dose Uncertainty Accumulation Model for IMRT
    Shiba, E.
    Saito, A.
    Tsuneda, M.
    Furumi, M.
    Yahara, K.
    Ohguri, T.
    Murakami, Y.
    Nishio, T.
    Korogi, Y.
    Nagata, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 2892 - 2892
  • [29] A study on the effect of detector resolution on gamma index passing rate for VMAT and IMRT QA
    Woon, WuiAnn
    Ravindran, Paul B.
    Ekayanake, Piyasiri
    Vikraman, S.
    Lim, Yivonne Y. F.
    Khalid, Jamsari
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 230 - 248
  • [30] New method for estimation of fluence complexity in IMRT fields and correlation with gamma analysis
    Hanusova, T.
    Vondracek, V.
    Badraoui-Cuprova, K.
    Horakova, I.
    Koniarova, I.
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573