Comparison of Strain Elastography, Shear Wave Elastography, and Conventional Ultrasound in Diagnosing Thyroid Nodules

被引:25
|
作者
Liao, Li-Jen [1 ,2 ,3 ]
Chen, Huan-Wen [4 ]
Hsu, Wan-Lun [5 ]
Chen, Yung-Sheng [2 ]
机构
[1] Far Eastern Mem Hosp, Dept Otolaryngol, New Taipei, Taiwan
[2] Yuan Ze Univ, Dept Elect Engn, Taoyuan, Taiwan
[3] Far Eastern Mem Hosp, Med Engn Off, New Taipei, Taiwan
[4] Lotung Poh Ai Hosp, Lo Hsu Med Fdn, Dept Internal Med, Yi Lan, Taiwan
[5] Acad Sinica, Genom Res Ctr, Taipei, Taiwan
关键词
Neck; real-time elastography; shear wave elastography; thyroid nodule; ultrasound; FINE-NEEDLE-ASPIRATION; MALIGNANCY; MANAGEMENT; CRITERIA; BENIGN;
D O I
10.4103/JMU.JMU_46_18
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The purpose of this study is to compare the diagnostic performances of strain elastography (SE), shear wave elastography (SWE), and traditional ultrasound (US) features in diagnosing thyroid nodules. Subjects and Methods: This study included 185 adult patients with thyroid nodules who underwent conventional gray-scale US, SE, and SWE. SE was scored using a four-pattern elastographic scoring (ES) system. SWE values were presented as mean SWE values and standard derivation using Young's modules. The optimal cutoff values of the mean SWE values for predicting malignancy were determined using receiver operating characteristic (ROC) curve analysis. We used logistic regression models to test elastography as a novel significant predictor for the diagnosis of malignant nodules. The diagnostic performance of elastography parameters was compared with a traditional trained model. Results: Malignant thyroid nodules were stiffer for SE (ES patterns 1 and 2/3 and 4) and mean SWE values (4/17; 51.0 +/- 24.4 kPa) than for benign nodules (114/50; 33.1 +/- 25.2 kPa) (P < 0.01). In ROC curve analyses, a mean SWE value of 32 kPa was the optimal cutoff point, with diagnostic performance measures of 81% sensitivity, 65% specificity, a 23% positive predictive value (PPV), and 96% negative predictive value (NPV). In multivariate logistic regression, the mean SWE value (>= 32 kPa) was an independent predictor for malignancy (odds ratio: 16.8; 95% confidence interval [CI]: 3.6-78.3). However, after the addition of SE and SWE to traditional US features, the C-statistic was not significantly increased compared to the traditional model (0.88, 95% CI: 0.81-0.94 vs. 0.91, 0.85-0.97, P = 0.4). Conclusion: In this study, we confirmed SWE as an independent predictor for malignant thyroid nodules. However, in comparing the new extended elastography model to our previous prediction model, the new extended model showed no significant difference in the diagnostic performance.
引用
收藏
页码:26 / 32
页数:7
相关论文
共 50 条
  • [21] The value of ultrasound elastography in differentiation of malignancy in thyroid nodules
    Akcay, Mehmet Arif
    Semiz-Oysu, Aslihan
    Ahiskali, Rengin
    Aribal, Erkin
    CLINICAL IMAGING, 2014, 38 (02) : 100 - 103
  • [22] Comb-Push Ultrasound Shear Elastography (CUSE) for Evaluation of Thyroid Nodules: Preliminary In Vivo Results
    Mehrmohammadi, Mohammad
    Song, Pengfei
    Meixner, Duane D.
    Fazzio, Robert T.
    Chen, Shigao
    Greenleaf, James F.
    Fatemi, Mostafa
    Alizad, Azra
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (01) : 97 - 106
  • [23] Suggested amendment of TI-RADS classification of thyroid nodules by shear wave elastography
    Yang, Jin-Ru
    Song, Yan
    Xue, Shan-Shan
    Ruan, Li-Tao
    ACTA RADIOLOGICA, 2020, 61 (08) : 1026 - 1033
  • [24] The values of shear wave elastography in avoiding repeat fine-needle aspiration for thyroid nodules with nondiagnostic and undetermined cytology
    Chen, Lin
    Shi, Yi-xin
    Liu, Ying-chun
    Zhan, Jia
    Diao, Xue-hong
    Chen, Yue
    Zhan, Wei-wei
    CLINICAL ENDOCRINOLOGY, 2019, 91 (01) : 201 - 208
  • [25] The influence of precompression on elasticity of thyroid nodules estimated by ultrasound shear wave elastography
    Lam, A. C. L.
    Pang, S. W. A.
    Ahuja, A. T.
    Bhatia, K. S. S.
    EUROPEAN RADIOLOGY, 2016, 26 (08) : 2845 - 2852
  • [26] The influence of precompression on elasticity of thyroid nodules estimated by ultrasound shear wave elastography
    A. C. L. Lam
    S. W. A. Pang
    A. T. Ahuja
    K. S. S. Bhatia
    European Radiology, 2016, 26 : 2845 - 2852
  • [27] Impact of Region-of-Interest Size on the Diagnostic Performance of Shear Wave Elastography in Differentiating Thyroid Nodules
    Cheng, Kai-Lun
    Lai, Pin-Hsien
    Su, Chun-Lang
    Baek, Jung Hwan
    Lee, Hsiang-Lin
    CANCERS, 2023, 15 (21)
  • [28] Quantitative assessment of shear-wave ultrasound elastography in thyroid nodules: diagnostic performance for predicting malignancy
    Hana Kim
    Jeong-Ah Kim
    Eun Ju Son
    Ji Hyun Youk
    European Radiology, 2013, 23 : 2532 - 2537
  • [29] ARTIFACTS IN SHEAR WAVE ELASTOGRAPHY IMAGES OF THYROID NODULES
    Dighe, Manjiri
    Hippe, Daniel S.
    Thiel, Jeff
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (06) : 1170 - 1176
  • [30] Objective ultrasound elastography scoring of thyroid nodules using spatiotemporal strain information
    Luo, Si
    Lim, Dong-Jun
    Kim, Yongmin
    MEDICAL PHYSICS, 2012, 39 (03) : 1182 - 1189