ART for head and neck patients: On the difference between VMAT and IMPT

被引:29
作者
Gora, Joanna [1 ,2 ]
Kuess, Peter [1 ,3 ]
Stock, Markus [1 ,2 ,3 ]
Andrzejewski, Piotr [1 ,3 ]
Knaeusl, Barbara [1 ,3 ]
Paskeviciute, Brigita [1 ]
Altorjai, Gabriela [1 ,3 ]
Georg, Dietmar [1 ,3 ]
机构
[1] Med Univ Vienna, AKH Wien, Dept Radiat Oncol, Vienna, Austria
[2] EBG MedAustron GmbH, A-2700 Wiener Neustadt, Austria
[3] Med Univ Vienna, Christian Doppler Lab Med Radiat Res Radiat Oncol, Vienna, Austria
关键词
MODULATED PROTON THERAPY; LOCALLY ADVANCED HEAD; DEFORMABLE REGISTRATION; ADAPTIVE RADIOTHERAPY; CANCER; UNCERTAINTIES; IMRT; PROSTATE; TARGETS; TUMORS;
D O I
10.3109/0284186X.2015.1028590
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Anatomical changes in the head-and-neck (H&N) region during the course of treatment can cause deteriorated dose distributions. Different replanning strategies were investigated for volumetric modulated arc therapy (VMAT) and intensity-modulated proton therapy (IMPT). Material and methods. For six H&N patients two repeated computed tomography (CT) and magnetic resonance (MR) (CT1/MR1 at week 2 and CT2,/MR2 at week 4) scans were acquired additionally to the initial planning CT/MR. Organs-at-risk (OARs) and three targets (CTV70Gy, CTV63Gy, CTV56Gy) were delineated on MRs and transferred to respective CT data set. Simultaneously integrated boost plans were created using VMAT (two arcs) and IMPT (four beams). To assess the need of replanning the initial VMAT and IMPT plans were recalculated on repeated CTs. Furthermore, VMAT and IMPT plans were replanned on the repeated CTs. A Demon algorithm was used for deformable registration of the repeated CTs with the initial CT and utilized for dose accumulation. Total dose estimations were performed to compare ART versus standard treatment strategies. Results. Dosimetric evaluation of recalculated plans on CT1 and CT2 showed increasing OAR doses for both, VMAT and IMPT. The target coverage of recalculated VMAT plans was considered acceptable in three cases, while for all IMPT plans it dropped. Adaptation of the treatment reduced D-2% for brainstem by 6.7 Gy for VMAT and by 8 Gy for IMPT, for particular patients. These D-2% reductions were reaching 9 Gy and 14 Gy for the spinal cord. ART improved target dose homogeneity, especially for protons, i.e. D-2% decreased by up to 8 Gy while D-98% increased by 1.2 Gy. Conclusion. ART showed benefits for both modalities. However, as IMPT is more conformal, the magnitude of dosimetric changes was more pronounced compared to VMAT. Large anatomic variations had a severe impact on treatment plan quality for both VMAT and IMPT. ART is justified in those cases irrespective of treatment modalities.
引用
收藏
页码:1166 / 1174
页数:9
相关论文
共 27 条
  • [1] Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system
    Barker, JL
    Garden, AS
    Ang, KK
    O'Daniel, JC
    Wang, H
    Court, LE
    Morrison, WH
    Rosenthal, DI
    Chao, KSC
    Tucker, SL
    Mohan, R
    Dong, L
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04): : 960 - 970
  • [2] Three-phase adaptive dose-painting-by-numbers for head-and-neck cancer: initial results of the phase I clinical trial
    Berwouts, Dieter
    Olteanu, Luiza A. M.
    Duprez, Frederic
    Vercauteren, Tom
    De Gersem, Werner
    De Neve, Wilfried
    Van de Wiele, Christophe
    Madani, Indira
    [J]. RADIOTHERAPY AND ONCOLOGY, 2013, 107 (03) : 310 - 316
  • [3] Assessment by a deformable registration method of the volumetric and positional changes of target volumes and organs at risk in pharyngo-laryngeal tumors treated with concomitant chemo-radiation
    Castadot, Pierre
    Geets, Xavier
    Lee, John Aldo
    Christian, Nicolas
    Gregoire, Vincent
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 209 - 217
  • [4] Daily kV cone-beam CT and deformable image registration as a method for studying dosimetric consequences of anatomic changes in adaptive IMRT of head and neck cancer
    Elstrom, Ulrik V.
    Wysocka, Barbara A.
    Muren, Ludvig P.
    Petersen, Jorgen B. B.
    Grau, Cai
    [J]. ACTA ONCOLOGICA, 2010, 49 (07) : 1101 - 1108
  • [5] A quantitative comparison of the performance of three deformable registration algorithms in radiotherapy
    Fabri, Daniella
    Zambrano, Valentina
    Bhatia, Amon
    Furtado, Hugo
    Bergmann, Helmer
    Stock, Markus
    Bloch, Christoph
    Luetgendorf-Caucig, Carola
    Pawiro, Supriyanto
    Georg, Dietmar
    Birkfellner, Wolfgang
    Figl, Michael
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (04): : 279 - 290
  • [6] Multifield Optimization Intensity Modulated Proton Therapy for Head and Neck Tumors: A Translation to Practice
    Frank, Steven J.
    Cox, James D.
    Gillin, Michael
    Mohan, Radhe
    Garden, Adam S.
    Rosenthal, David I.
    Gunn, G. Brandon
    Weber, Randal S.
    Kies, Merrill S.
    Lewin, Jan S.
    Munsell, Mark F.
    Palmer, Matthew B.
    Sahoo, Narayan
    Zhang, Xiaodong
    Liu, Wei
    Zhu, X. Ronald
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 89 (04): : 846 - 853
  • [7] Is there room for combined modality treatments? Dosimetric comparison of boost strategies for advanced head and neck and prostate cancer
    Gora, Joanna
    Hopfgartner, Johannes
    Kuess, Peter
    Paskeviciute, Brigita
    Georg, Dietmar
    [J]. JOURNAL OF RADIATION RESEARCH, 2013, 54 : 97 - 112
  • [8] Is There an Advantage in Designing Adapted, Patient-Specific PTV Margins in Intensity Modulated Proton Beam Therapy for Prostate Cancer?
    Gora, Joanna
    Stock, Markus
    Luetgendorf-Caucig, Carola
    Georg, Dietmar
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (03): : 881 - 888
  • [9] Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer
    Hansen, EK
    Bucci, MK
    Quivey, JM
    Weinberg, V
    Xia, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02): : 355 - 362
  • [10] Robustness of IMPT treatment plans with respect to inter-fractional set-up uncertainties: Impact of various beam arrangements for cranial targets
    Hopfgartner, Johannes
    Stock, Markus
    Knaeusl, Barbara
    Georg, Dietmar
    [J]. ACTA ONCOLOGICA, 2013, 52 (03) : 570 - 579