A randomized equivalence trial comparing the i-gel and laryngeal mask airway Supreme in children

被引:43
|
作者
Jagannathan, Narasimhan [1 ]
Sommers, Katherine [1 ]
Sohn, Lisa E. [1 ]
Sawardekar, Amod [1 ]
Shah, Ravi D. [1 ]
Mukherji, Isabella I. [1 ]
Miller, Steven [1 ]
Voronov, Polina [1 ]
Seraphin, Sally [1 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Pediat Anesthesia, Ann & Robert H Lurie Childrens Hosp Chicago, Chicago, IL 60611 USA
关键词
airway; devices; clinical trial; NON-PARALYZED PATIENTS; SUPRAGLOTTIC AIRWAY; PEDIATRIC-PATIENTS; COHORT EVALUATION; I-GEL(TM) AIRWAY; PROSEAL(TM); ANESTHESIA; SURGERY;
D O I
10.1111/pan.12078
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background The laryngeal mask airway Supreme (Supreme) is a new single-use supraglottic device with gastric access capability now available in all sizes for children. Objectives To compare the i-gel with the Supreme in children for routine airway maintenance. Materials/Methods One hundred and seventy children, aged 3 months to 11 years, 550 kg in weight, were randomly assigned to receive either the i-gel or the Supreme. The primary outcome measured was airway leak pressure. Secondary outcomes included the following: ease and time for insertion, insertion success rate, fiberoptic grade of view, ease of gastric tube placement, number of airway manipulations, quality of airway during anesthetic maintenance, and complications. Results A total of 168 patients were assessed for the outcomes. The median (IQR [range]) airway leak pressure for the i-gel was higher than with the Supreme, 20 (1825 [940]) cm H2O vs 17 (1422 [1040]) cm H2O, respectively (P = 0.001). There were no differences in the time for device insertion, fiberoptic grade of view, quality of airway, and complications. Median (IQR[range]) time of successful insertion of a gastric tube was faster with the Supreme, 12 (9.214.3 [5.244.2]) s than with the i-gel, 14 (11.919 [6.975]) s; P = 0.01. The number of airway manipulations during placement was higher with the i-gel than with the laryngeal mask airway Supreme (12 vs 13 patients), P = 0.02. Conclusions In infants and children, when a single-use supraglottic device with gastric access capabilities is required, the i-gel demonstrated higher airway leak pressures and can be a useful alternative to the Supreme.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 50 条
  • [21] Comparison between I-Gel and Classic Laryngeal Mask Airway for Airway Management of Patients with Anticipated Difficult Airway: A Randomised Clinical Trial
    Raman, Rajesh
    Gautam, Shefali
    Sonkar, Suraj
    Prabha, Rati
    Alam, Sharif
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (10) : UC10 - UC13
  • [22] Head elevation and laryngeal mask airway Supreme insertion: A randomized controlled trial
    Park, Jun-Young
    Yu, Jihion
    Hong, Jun Hyuk
    Hwang, Jai-Hyun
    Kim, Young-Kug
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2021, 65 (03) : 343 - 350
  • [23] A randomized trial comparing two laryngeal mask airway insertion techniques
    Koay, CK
    Yoong, CS
    Kok, P
    ANAESTHESIA AND INTENSIVE CARE, 2001, 29 (06) : 613 - 615
  • [24] A prospective study to evaluate and compare laryngeal mask airway ProSeal and i-gel airway in the prone position
    Taxak, Susheela
    Gopinath, Ajith
    Saini, Savita
    Bansal, Teena
    Ahlawat, Mangal Singh
    Bala, Manju
    SAUDI JOURNAL OF ANAESTHESIA, 2015, 9 (04) : 446 - 450
  • [25] A cohort evaluation of the Laryngeal Mask Airway-Supreme™ in children
    Jagannathan, Narasimhan
    Sohn, Lisa E.
    Chang, Edwina
    Sawardekar, Amod
    PEDIATRIC ANESTHESIA, 2012, 22 (08) : 759 - 764
  • [26] Evaluation of i-gel™ airway in children: a meta-analysis
    Maitra, Souvik
    Baidya, Dalim K.
    Bhattacharjee, Sulagna
    Khanna, Puneet
    PEDIATRIC ANESTHESIA, 2014, 24 (10) : 1072 - 1079
  • [27] The LMA-Supreme versus the I-gel in simulated difficult airway in children A randomised study
    Kus, Alparslan
    Gok, Cigdem N.
    Hosten, Tulay
    Gurkan, Yavuz
    Solak, Mine
    Toker, Kamil
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 (05) : 280 - 284
  • [28] Comparison of I-gel with Classic Laryngeal Mask Airway Regarding the Ease of Use and Clinical Performance
    Ari, Dilek Erdogan
    Ar, Arzu Yildirim
    Karip, Ceren Sanli
    Siyahkoc, Incifer
    Arslan, Ahmet Hakan
    Akgun, Fatma Nur
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2015, 43 (05) : 299 - 303
  • [29] Supreme Laryngeal Mask Airway versus Face Mask during Neonatal Resuscitation: A Randomized Controlled Trial
    Trevisanuto, Daniele
    Cavallin, Francesco
    Loi Ngoc Nguyen
    Tien Viet Nguyen
    Linh Dieu Tran
    Chien Dinh Tran
    Doglioni, Nicoletta
    Micaglio, Massimo
    Moccia, Luciano
    JOURNAL OF PEDIATRICS, 2015, 167 (02): : 286 - +
  • [30] Comparison of fibrescope guided intubation via the classic laryngeal mask airway and i-gel in a manikin
    de Lloyd, L.
    Hodzovic, I.
    Voisey, S.
    Wilkes, A. R.
    Latto, I. P.
    ANAESTHESIA, 2010, 65 (01) : 36 - 43