A Study on the Influence of Stage Load on Health Monitoring of Axial Concrete Members Using Piezoelectric Based Smart Aggregate

被引:6
作者
Du, Chengcheng [1 ]
Zou, Dujian [1 ]
Liu, Tiejun [1 ]
Li, Weijie [1 ]
机构
[1] Harbin Inst Technol, Shenzhen Grad Sch, Shenzhen 518055, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2018年 / 8卷 / 03期
基金
美国国家科学基金会;
关键词
stage load; smart aggregate; structural health monitoring; TRANSDUCERS;
D O I
10.3390/app8030423
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Piezoceramic based smart aggregate (SA) has been employed to monitor the strength development of early age concrete. The validity of SA-based active sensing method was tested and verified with loading and unloading conditions. However, the early age concrete in buildings is subjected to many load increments during the construction process. The influence of incremental load on the properties of the propagating waves is still unclear. This study aims to investigate the effects of axial stage loads on the signal response of the SA. The concrete specimens that are embedded with SA's were loaded step by step, and the amplitude and wave velocity of the sensing signals were measured at each stress state. The experimental results indicated that the amplitude of the received signal decrease with the increase of the stress level. As for the velocity of the propagated stress wave, however, the velocity shows an increasing trend before a sharp decline at high stress level.
引用
收藏
页数:10
相关论文
共 32 条
  • [1] [Anonymous], 2002, P 3 WORLD C STRUCT C
  • [2] [Anonymous], 2010, GB500102010 MIN HOUS
  • [3] Electrical effects generated by mechanical loading of hardened Portland cement paste
    Cabeza, M
    Merino, P
    Nóvoa, XR
    Sánchez, I
    [J]. CEMENT & CONCRETE COMPOSITES, 2003, 25 (03) : 351 - 356
  • [4] Real-Time Strength Monitoring for Concrete Structures Using EMI Technique Incorporating with Fuzzy Logic
    Choi, Sang-Ki
    Tareen, Najeebullah
    Kim, Junkyeong
    Park, Seunghee
    Park, Innjoon
    [J]. APPLIED SCIENCES-BASEL, 2018, 8 (01):
  • [5] Comite Euro-International Du Beton (CEB), 1990, CEB-FIP model code for concrete structures
  • [6] Study of the chloride diffusion in mortar:: A new method of determining diffusion coefficients based on impedance measurements
    Díaz, B
    Nóvoa, XR
    Pérez, MC
    [J]. CEMENT & CONCRETE COMPOSITES, 2006, 28 (03) : 237 - 245
  • [7] Du C., 2017, MEASUREMENT
  • [8] Time dependent strain development of early age concrete under step-by-step load history
    Du, Chengcheng
    Liu, Tiejun
    Zou, Dujian
    Teng, Jun
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2015, 86 : 133 - 139
  • [9] Concrete early-age strength monitoring using embedded piezoelectric transducers
    Gu, H.
    Song, G.
    Dhonde, H.
    Mo, Y. L.
    Yan, S.
    [J]. SMART MATERIALS & STRUCTURES, 2006, 15 (06) : 1837 - 1845
  • [10] Integrating embedded piezoelectric sensors with continuous wavelet transforms for real-time concrete curing strength monitoring
    Kim, Ju-Won
    Kim, Junkyeong
    Park, Seunghee
    Oh, Tae Keun
    [J]. STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2015, 11 (07) : 897 - 903