Impact of electrode tip shape on catheter performance in cardiac radiofrequency ablation

被引:4
|
作者
Petras, Argyrios [1 ]
Moreno Weidmann, Zoraida [2 ]
Echeverria Ferrero, Marina [3 ]
Leoni, Massimiliano
Guerra, Jose M. [2 ]
Gerardo-Giorda, Luca [1 ,4 ]
机构
[1] Austrian Acad Sci, RICAM, Linz, Austria
[2] Univ Autonoma Barcelona, Hosp Santa Creu & St Pau, Dept Cardiol, IIB ST PAU,CIBERCV, Barcelona, Spain
[3] BCAM Basque Ctr Appl Math, Bilbao, Spain
[4] Johannes Kepler Univ Linz, Inst Math Methods Med & Data Based Modelling, Linz, Austria
来源
HEART RHYTHM O2 | 2022年 / 3卷 / 06期
关键词
Cardiac ablation; Computational modeling and simulation; Electrode tip; Lesion science; Open irrigation; Radiofrequency; Steam pop; CONTACT FORCE; LESION SIZE; TEMPERATURE;
D O I
10.1016/j.hroo.2022.07.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The role of catheter tip shape on the safety and efficacy of radiofrequency (RF) ablation has been overlooked, although differences have been observed in clinical and research fields. OBJECTIVE The purpose of this study was to analyze the role of electrode tip shape in RF ablation using a computational model. METHODS We simulated 108 RF ablations through a realistic 3-dimensional computational model considering 2 clinically used, open-irrigated catheters (spherical and cylindrical tip), varying contact force (CF), blood flow, and irrigation. Lesions are defined by the 50 degrees C isotherm contour and evaluated by means of width, depth, depth at maximum width, and volume. Ablations are deemed as safe, critical (tissue temperature.90 degrees C), and pop (tissue temperature.100 degrees C). RESULTS Tissue-electrode contact is less for the spherical tip at low CF but the relationship is inverted at high CF. At low CF, the cylindrical tip generates deeper and wider lesions and a 4-fold larger volume. With increasing CF, the lesions generated by the spherical tip become comparable to those generated by the cylindrical tip. The 2 tips feature different safety profiles: CF and power are the main determinants of pops for the spherical tip; power is the main factor for the cylindrical tip; and CF has a marginal effect. The cylindrical tip is more prone to pop generation at higher powers. Saline irrigation and blood flow effect do not depend on tip shape. CONCLUSION Tip shape determines the performance of ablation catheters and has a major impact on their safety profile. The cylindrical tip shows more predictable behavior in a wide range of CF values.
引用
收藏
页码:699 / 705
页数:7
相关论文
共 50 条
  • [31] A real-time tip manometer for radiofrequency catheter ablation: new toy or useful tool?
    Zellerhoff, Stephan
    Eckardt, Lars
    Kirchhof, Paulus
    EUROPACE, 2011, 13 (02): : 159 - 160
  • [32] Temperature-Controlled Radiofrequency Catheter Ablation with a 10-mm Tip Electrode Creates Larger Lesions without Charring in the Porcine Heart
    Ole-Gunnar Anfinsen
    Halfdan Aass
    Erik Kongsgaard
    Arnold Foerster
    Helge Scott
    Jan Peder Amlie
    Journal of Interventional Cardiac Electrophysiology, 1999, 3 : 343 - 351
  • [33] Temperature-controlled radiofrequency catheter ablation with a 10-mm tip electrode creates larger lesions without charring in the porcine heart
    Anfinsen, OG
    Aass, H
    Kongsgaard, E
    Foerster, A
    Scott, H
    Amlie, JP
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1999, 3 (04) : 343 - 351
  • [34] Lesion Characteristics Using a Novel Multi-Electrode Radiofrequency Balloon Ablation Catheter
    Lee, Byron K.
    Al-Ahmad, Amin
    Rippy, Marian
    Reddy, Vivek
    Narayan, Girish
    Kuck, Karl-Heinz
    Crozier, Ian
    Daly, Matt
    Melton, Iain
    Walters, Tomas E.
    Lee, Randall J.
    Badhwar, Nitish
    CIRCULATION, 2016, 134
  • [35] BASIC ASPECTS OF RADIOFREQUENCY CATHETER ABLATION
    NATH, S
    DIMARCO, JP
    HAINES, DE
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1994, 5 (10) : 863 - 876
  • [36] Radiofrequency catheter ablation of atrial tachycardias
    Llorens, JLM
    Maiz, AA
    PerezVillacastin, J
    Garrote, JA
    Peinado, RP
    Moreno, OM
    Monedero, CM
    Dominguez, JLD
    REVISTA ESPANOLA DE CARDIOLOGIA, 1997, 50 (04): : 239 - 247
  • [37] Radiofrequency catheter ablation of ventricular tachycardias
    Brunckhorst, C
    Delacrétaz, E
    Duru, F
    Lemola, C
    Rosenfeldt, R
    Candinas, R
    ZEITSCHRIFT FUR KARDIOLOGIE, 2002, 91 (01): : 2 - +
  • [38] Catheter ablation using advanced porous tip contact force-sensing radiofrequency catheter: Impact on health care utilization among patients with persistent atrial fibrillation
    Doshi, Amit
    Maccioni, Sonia
    Preethi, Sariki Meghana
    Khanna, Rahul
    HEART RHYTHM O2, 2022, 3 (05): : 474 - 481
  • [39] Predictors of Asymptomatic Cerebral Infarction associated with Radiofrequency Catheter Ablation for Atrial Fibrillation using an Irrigated-tip Catheter.
    Sakamoto, Tamotsu
    Kumagai, Koji
    Fuke, Etsuko
    Hayashi, Tatsuya
    Sato, Chizuru
    Miki, Yuko
    Nakamura, Keijiro
    Fukazawa, Rie
    Goto, Kouji
    Kaseno, Kenichi
    Naito, Shigeto
    Oshima, Shigeru
    CIRCULATION, 2010, 122 (21)
  • [40] Multiple Cardiac Perforations Following Radiofrequency Catheter Ablation: Case Report and Literature Reviews
    Liu, Peng
    Ren, Shiyan
    Qian, Songyi
    Wang, Fei
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 18 (04) : 370 - 374