Impact of electrode tip shape on catheter performance in cardiac radiofrequency ablation

被引:4
|
作者
Petras, Argyrios [1 ]
Moreno Weidmann, Zoraida [2 ]
Echeverria Ferrero, Marina [3 ]
Leoni, Massimiliano
Guerra, Jose M. [2 ]
Gerardo-Giorda, Luca [1 ,4 ]
机构
[1] Austrian Acad Sci, RICAM, Linz, Austria
[2] Univ Autonoma Barcelona, Hosp Santa Creu & St Pau, Dept Cardiol, IIB ST PAU,CIBERCV, Barcelona, Spain
[3] BCAM Basque Ctr Appl Math, Bilbao, Spain
[4] Johannes Kepler Univ Linz, Inst Math Methods Med & Data Based Modelling, Linz, Austria
来源
HEART RHYTHM O2 | 2022年 / 3卷 / 06期
关键词
Cardiac ablation; Computational modeling and simulation; Electrode tip; Lesion science; Open irrigation; Radiofrequency; Steam pop; CONTACT FORCE; LESION SIZE; TEMPERATURE;
D O I
10.1016/j.hroo.2022.07.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The role of catheter tip shape on the safety and efficacy of radiofrequency (RF) ablation has been overlooked, although differences have been observed in clinical and research fields. OBJECTIVE The purpose of this study was to analyze the role of electrode tip shape in RF ablation using a computational model. METHODS We simulated 108 RF ablations through a realistic 3-dimensional computational model considering 2 clinically used, open-irrigated catheters (spherical and cylindrical tip), varying contact force (CF), blood flow, and irrigation. Lesions are defined by the 50 degrees C isotherm contour and evaluated by means of width, depth, depth at maximum width, and volume. Ablations are deemed as safe, critical (tissue temperature.90 degrees C), and pop (tissue temperature.100 degrees C). RESULTS Tissue-electrode contact is less for the spherical tip at low CF but the relationship is inverted at high CF. At low CF, the cylindrical tip generates deeper and wider lesions and a 4-fold larger volume. With increasing CF, the lesions generated by the spherical tip become comparable to those generated by the cylindrical tip. The 2 tips feature different safety profiles: CF and power are the main determinants of pops for the spherical tip; power is the main factor for the cylindrical tip; and CF has a marginal effect. The cylindrical tip is more prone to pop generation at higher powers. Saline irrigation and blood flow effect do not depend on tip shape. CONCLUSION Tip shape determines the performance of ablation catheters and has a major impact on their safety profile. The cylindrical tip shows more predictable behavior in a wide range of CF values.
引用
收藏
页码:699 / 705
页数:7
相关论文
共 50 条
  • [21] Safe and effective delivery of high-power, short-duration radiofrequency ablation lesions with a flexible-tip ablation catheter
    Ptaszek, Leon M.
    Koruth, Jacob
    Santangeli, Pasquale
    Piccini, Jonathan P.
    Ranjan, Ravi
    Mahapatra, Srijoy
    Pipenhagen, Catherine
    Fish, Jeffrey M.
    Moon, L. Boyce
    Ambrosius, Nicholas M.
    Boudlali, Hana
    Jensen, James A.
    HEART RHYTHM O2, 2023, 4 (01): : 42 - 50
  • [22] Insulated Radiofrequency Ablation Catheter
    Huang, Janice V.
    Sauer, William
    Zheng, Lijun
    Barham, Waseem
    Nguyen, Duy T.
    CIRCULATION, 2014, 130
  • [23] Quantification of local convectional cooling during cardiac radiofrequency catheter ablation
    Haemmerich, D.
    Saul, J. P.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 100 - 103
  • [24] Radiofrequency ablation using a novel insulated-tip ablation catheter can create uniform lesions comparable in size to conventional irrigated ablation catheters while using a fraction of the energy and irrigation
    Aryana, Arash
    Irastorza, Ramiro M.
    Berjano, Enrique
    Cohen, Richard J.
    Kraus, Jeffrey
    Haghighi-Mood, Ali
    Reddy, Vivek Y.
    d'Avila, Andre
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (06) : 1146 - 1156
  • [25] Biophysics of Radiofrequency Ablation for Cardiac Arrhythmias: A Current Review
    Matos, Carlos D.
    Romero, Jorge E.
    Steiger, Nathaniel A.
    CURRENT TREATMENT OPTIONS IN CARDIOVASCULAR MEDICINE, 2024, 26 (08) : 221 - 231
  • [26] Irrigated Tip Catheters for Radiofrequency Ablation in Ventricular Tachycardia
    Muessigbrodt, Andreas
    Grothoff, Matthias
    Dinov, Borislav
    Kosiuk, Jedrzej
    Richter, Sergio
    Sommer, Philipp
    Breithardt, Ole A.
    Rolf, Sascha
    Bollmann, Andreas
    Arya, Arash
    Hindricks, Gerhard
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [27] Cardiac Radiofrequency Ablation
    Shoulders, Bridget
    Mauriello, Jillian
    Shellman, Tamika
    Follett, Corrinne
    DIMENSIONS OF CRITICAL CARE NURSING, 2016, 35 (05) : 255 - 267
  • [28] Computer simulation study on the effect of electrode-tissue contact force on thermal lesion size in cardiac radiofrequency ablation
    Yan, Shengjie
    Gu, Kaihao
    Wu, Xiaomei
    Wang, Weiqi
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) : 37 - 48
  • [29] Impedance-decline-guide power control long application time bipolar radiofrequency catheter ablation
    Saitoh, Osamu
    Kasai, Takumi
    Fuse, Kyogo
    Oikawa, Ayaka
    Furushima, Hiroshi
    Chinushi, Masaomi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (12) : 2538 - 2545
  • [30] The effect of contact force during radiofrequency catheter ablation using a vibrating catheter: New cooling method for catheter ablation
    Yu, Kaihong
    Yamashita, Tetsui
    Shingyochi, Shigeaki
    Matsumoto, Kazuo
    Komiya, Atsuki
    Ohta, Makoto
    TECHNOLOGY AND HEALTH CARE, 2019, 27 (06) : 589 - 601