Understanding the water column nutrient dynamics is fundamental to quantifying primary productivity and the assessment of water quality. Nutrients such as nitrate ammonia and phosphate are typically evaluated from field samples, collected, transported, stored and analysed in the lab. Sample processing is time consuming and impractical for studies requiring high spatial and/or temporal resolution. In addition, sample handling and storage can introduce contamination and analysis errors. This paper discusses the development of a engineering prototype, the chemical process, testing and the deployment of a high resolution nitrate sensor. The mechanical, electrical and control systems are reviewed in detail. Data analysis and processing is also discussed. Preliminary sensor results are presented and compared to conventional sampling techniques. Finally, the paper outlines future work and improvements.
引用
收藏
页数:7
相关论文
共 10 条
[1]  
Bende-Michl U, 2010, J ENVIRON MONITOR, V12, P127, DOI [10.1039/b910156j, 10.1039/0110156j, 10.1039/B910156J]
[2]   Field measurement of nitrate in marine and estuarine waters with a flow analysis system utilizing on-line zinc reduction [J].
Ellis, Peter S. ;
Shabani, Ali Mohammad Haji ;
Gentle, Brady S. ;
McKelvie, Ian D. .
TALANTA, 2011, 84 (01) :98-103
[3]   Multi-reflection photometric flow cell for use in flow injection analysis of estuarine waters [J].
Ellis, PS ;
Lyddy-Meaney, AJ ;
Worsfold, PJ ;
McKelvie, ID .
ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) :81-89
[4]   Spectrophotometric determination of ammonia in estuarine waters by hybrid reagent-injection gas-diffusion flow analysis [J].
Gray, Sarah M. ;
Ellis, Peter S. ;
Grace, Michael R. ;
McKelvie, Ian D. .
SPECTROSCOPY LETTERS, 2006, 39 (06) :737-753
[5]   A compact flow injection analysis system for surface mapping of phosphate in marine waters [J].
Lyddy-Meaney, AJ ;
Ellis, PS ;
Worsfold, PJ ;
Butler, ECV ;
McKelvie, ID .
TALANTA, 2002, 58 (06) :1043-1053
[6]  
Miller F.P., 2009, Beer-Lambert Law
[7]   Improved algorithm for the computation of nitrate concentrations in seawater using an in situ ultraviolet spectrophotometer [J].
Sakamoto, Carole M. ;
Johnson, Kenneth S. ;
Coletti, Luke J. .
LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2009, 7 :132-143
[8]  
Satlantic, 2010, SUNA SUBM ULTR NITR
[9]  
Verburg K., J ENV MONITORI UNPUB
[10]  
Wild-Allen K., 2010, J MARINE SYSTEMS, V81