Comparision of four different dose specification methods for high-dose-rate intracavitary radiation for treatment of cervical cancer

被引:19
|
作者
Mai, J [1 ]
Erickson, B [1 ]
Rownd, J [1 ]
Gillin, M [1 ]
机构
[1] Med Coll Wisconsin, Dept Radiat Oncol, Milwaukee, WI 53226 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 51卷 / 04期
关键词
cervix cancer; brachytherapy; dosimetry; high-dose rate (HDR);
D O I
10.1016/S0360-3016(01)01771-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare the dose delivered to target tissues and dose-limiting structures as defined by specific dose points with high-dose-rate intracavitary brachytherapy using tandem and ring or tandem and ovoids applicators, and to provide a reasonable approach to dose optimization. Methods and Materials: Dosimetry was obtained using four different dose specifications: (1) 100% of the dose prescribed in a tapered fashion along the tandem and 140% at the ovoid/ring surface, (2) 100% of the dose prescribed along the tandem and 100% at the ovoid/ring surface, (3) 100% of the dose prescribed to point A without any additional applicator specification points, and (4) nonoptimized plan using relative dwell weighting to simulate classic Fletcher low-dose-rate (LDR) loading with the dose specified at point A. Point doses were recorded at A, B, and T (cervical tumor point), ICRU rectum, and ovoid/ring surface. Results: For the tandem and ovoids applicators, significant differences were found among the four different dose specification methods for point T and vaginal mucosal doses. When the dose was optimized to point A alone, the ovoid dwell weights were reduced, resulting in higher point T doses and underdosing of the vaginal mucosa. Fixed weighting based on Fletcher LDR loading specifications resulted in higher vaginal mucosa doses. For the tandem and ring applicators, significant differences were observed for vaginal mucosal doses and the ICRU rectal dose. Optimization to point A alone resulted in widely varying dosimetric distributions and vaginal mucosa doses up to 632% of the prescription dose. With nonoptimized fixed weighting, the vaginal wall dose and ICRU rectal dose were increased. Conclusion: Prescribing to dose optimization points in a tapered fashion along the tandem and at the ovoid/ring surface results in a pear-shaped dose distribution resembling classic LDR systems. The other dose specification methods may result in underdosing of important target tissues or overdosing of adjacent dose-limiting structures. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:1131 / 1141
页数:11
相关论文
共 50 条
  • [21] Inverse planning simulated annealing for magnetic resonance imaging-based intracavitary high-dose-rate brachytherapy for cervical cancer
    Kubicky, Charlotte Dai
    Yeh, Benjamin M.
    Lessard, Etienne
    Joe, Bonnie N.
    Speight, Joycelyn L.
    Pouliot, Jean
    Hsu, I-Chow
    BRACHYTHERAPY, 2008, 7 (03) : 242 - 247
  • [22] Treatment patterns of high-dose-rate and low-dose-rate brachytherapy as monotherapy for prostate cancer
    Barnes, Justin
    Kennedy, William R.
    Fischer-Valuck, Benjamin W.
    Baumann, Brian C.
    Michalski, Jeff M.
    Gay, Hiram A.
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (04) : 320 - 328
  • [23] Low-dose-rate or high-dose-rate brachytherapy in treatment of prostate cancer - between options
    Skowronek, Janusz
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (01) : 33 - 41
  • [24] Deep reinforcement learning for treatment planning in high-dose-rate cervical brachytherapy
    Pu, Gang
    Jiang, Shan
    Yang, Zhiyong
    Hu, Yuanjing
    Liu, Ziqi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 94 : 1 - 7
  • [25] HIGH-DOSE-RATE INTRACAVITARY BRACHYTHERAPY OF EARLY AND SUPERFICIAL CARCINOMA OF THE NASAL VESTIBULE AS AN ALTERNATIVE TO LOW-DOSE RATE INTERSTITIAL RADIATION-THERAPY
    POP, LAM
    KAANDERS, JHAM
    HEINERMAN, ECM
    RADIOTHERAPY AND ONCOLOGY, 1993, 27 (01) : 69 - 72
  • [26] Factors affecting the dosimetry of high-dose rate intracavitary brachytherapy in cervical cancer
    Mahapatra, Bikash Ranjan
    Barik, Sandip Kumar
    Das, Deepak Kumar
    Das Majumdar, Saroj Kumar
    Parida, Dillip Kumar
    Ramasubbu, Mathan Kumar
    Badajena, Avinash
    Barik, Bijay Kumar
    Mishra, Minakshi
    Pattanaik, Ashutosh
    Kanungo, Satyabrata
    Muraleedharan, Anupam
    Ahmed, Sk Soel
    Mukherjee, Priyanka
    Abdulla, Shaha Sheik
    Mahajan, Ankur
    Sarkar, Arnab
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2024, 23
  • [27] The prediction of late rectal complications following the treatment of uterine cervical cancer by high-dose-rate brachytherapy
    Chen, SW
    Liang, JA
    Yang, SN
    Liu, RT
    Lin, FJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (04): : 955 - 961
  • [28] Three-dimensional image-guided combined intracavitary and interstitial high-dose-rate brachytherapy in cervical cancer: A systematic review
    Li, Fei
    Lu, Shuangchen
    Zhao, Hongfu
    Mu, Xin
    Mao, Zhuang
    BRACHYTHERAPY, 2021, 20 (01) : 85 - 94
  • [29] Hypofractionated high-dose-rate plesiotherapy in nonmelanoma skin cancer treatment
    Arenas, Meritxell
    Arguis, Monica
    Diez-Presa, Lorena
    Henriquez, Ivan
    Murcia-Mejia, Mauricio
    Gascon, Marina
    Gomez, David
    Lafuerza, Anna
    Mur, Encarna
    Azon, Antoni
    Rovirosa, Angels
    Sabater, Sebastia
    BRACHYTHERAPY, 2015, 14 (06) : 859 - 865
  • [30] An analysis of simulation for adjuvant intracavitary high-dose-rate brachytherapy in early-stage endometrial cancer
    Barney, Brandon M.
    MacDonald, O. Kenneth
    Lee, Christopher M.
    Rankin, Jim
    Gaffney, David K.
    BRACHYTHERAPY, 2007, 6 (03) : 201 - 206